Standard Series Twin Switch Socket Outlet 250V, 10A, Standard Size | Red
Item Number: 25-RD
Datasheet
Specifications
Design
| Range of product | Standard Series |
|---|---|
| Product brand | Clipsal |
| Surface finish | glossy |
Physical
| Control type | ON/OFF button |
|---|---|
| Number of gangs | 2 gangs |
| Pin number | 3 |
| Number of power socket outlets | 2 |
| Actuator |
|
| Fixing mode | by screws |
| Local signalling | without light indicator |
| Mounting position | horizontal |
| [ue] rated operational voltage | 250 V AC |
| [in] rated current | 10 A |
| Depth | 16 mm |
| Length | 115 mm |
| Width | 73 mm |
| Fixing center | 84 mm |
| Standards |
|
| Mercury free | Yes |
| Rohs exemption information | Yes |
| Environmental disclosure | ENVPEP120506EN_V2 |
| Eu rohs directive | Compliant By Exemption |
Material
| Material | PC (polycarbonate) |
|---|
Documents & downloads
-
All
-
Technical Data Catalogues
-
Specification Guide
-
Certificates (MSDS)
-
Declaration of Conformity
-
Declaration of Conformity (Sustainability)
Frequently Asked Questions
How do I swap my Wiser connected socket outlet from BLE to Zigbee?
Hide ShowDownload the Wiser Room App, if you don’t have it on your smart device, and open it. Within Wiser Room tap Edit at the top right and select ‘Add New Device’. Follow the instructions and pair your socket with Wiser Room. Once paired in Wiser Room, tap on the socket and then tap on the cog to enter the settings of the device. Tap on Advanced Settings, tap on Device Information and then proceed to update the Firmware of the socket.
Once the firmware update is completed and you can re-connect to the device once again check to make sure there are no more firmware updates. Once confirmed remove the socket from Wiser Room App by tapping Edit in the top right and then delete the device. Open the Bluetooth settings on your phone and once again remove the socket from here.
To then swap the socket from Bluetooth to Zigbee tap the touch switch LED panel 12 times. When the swap is completed you will see both the left and right LED on the panel blinking together indicating you are in Zigbee mode. Tap the touch switch panel to stop the blinking.
In Wiser by SE, go to the home you wish to add the socket to and tap the plus symbol in the top right corner. Go to the Add with Hub option and select the Iconic Socket and follow the instructions, tap the LED panel 3 times as per the animation and confirm that both LED’s on the panel are flashing.
Modicon M258 stuck in a boot loop after a firmware update?
Hide ShowQuestion:
A Modicon M258 controller powers up, all LEDs turn on briefly, RUN/MS flashes or turns off, and the Ethernet LEDs continue flashing red/green in a repeating 3-flash cycle. What can cause this boot loop and how can it be recovered?
Answer:
This behaviour could occur if the firmware loaded into the Modicon M258 is not compatible with the controller hardware version.
For M258 PV16 / hardware version 4 controllers, the required firmware depends on the SoMachine version being used:
- SoMachine V3.x: firmware V2.0.31.40
- SoMachine V4.x: firmware V4.0.3.6
Using an incompatible firmware version can cause the controller to reboot continuously and fail to complete startup.
The recommended recovery method is to reload the correct firmware using a USB memory key. Firmware update by USB key is preferred because older versions of Controller Assistant may not check the M258/LMC058 hardware version before downloading firmware. This can allow an incompatible firmware version to be loaded.
After the correct firmware has been reloaded:
1. Reconnect to the controller using the appropriate SoMachine version.
2. Download the correct application.
3. Update the boot application.
4. Power cycle the controller and confirm that the controller starts normally.
If the controller remains in a boot loop after reloading the correct firmware by USB key, and the correct firmware version for the hardware has been confirmed, no further recovery action may be available. In this condition, the controller may be permanently damaged and require replacement.
References:
- For USB firmware reload procedure, refer to Schneider Electric FAQ FA339601.
- For setting the M258/LMC058 to start in RUN mode and updating the boot application, refer to Schneider Electric FAQ FA243994.
How do I convert Iconic Wiser™ Connected Socket from Zigbee to BLE
Hide ShowSee below video
What is the IP rating for the Iconic Outdoor sockets?
Hide ShowDo the conduit caps come with the Iconic Outdoor?
Hide ShowHow do you remove the cover from Iconic Outdoor once its clipped on?
Hide ShowDoes the Iconic Outdoor socket maintain IP54 when a plug is inserted?
Hide ShowDoes the Iconic outlets fit the Tal Plus skirting duct?
Hide ShowThe power shrouds (PLPSK) are not large enough for the back of the outlet to fit in.
Will the Pro series outlets fit in the Tal Plus skirting duct?
Hide ShowThe power shrouds (PLPSK) are not large enough for the back of the outlet to fit in.
Do I need to use any caps or silicone on the mounting screws on the Iconic Outdoor?
Hide ShowWhat size conduit entries can be used with Iconic Outdoor?
Hide ShowWhat shroud would fit the 3025USBC?
Hide ShowDALI broadcasts messaging from the DALI gateway vs DALI broadcasts from a DALI Dual Power Supply via the override Push Buttons
Hide ShowThe differential of the DALI broadcasts messaging from the DALI gateway via a C-Bus Group vs Sending broadcasts from a DALI Dual Power Supply via the Push Buttons on the front of the power supply.
-
Sending broadcasts from the DALI gateway via a C-Bus Group.
-
Sending broadcasts from a DALI Dual Power Supply via the Push Buttons on the front of the power supply.
They're different commands with the same outcome.
Sending broadcast from the DALI gateway via a C-Bus Group use ARC command i.e it come with a fade time before the ARC power level of 254(100%) and 0(Off)
Sending broadcast from a DALI Dual Power Supply via the Push Buttons on the front of the power supply is direct Max and Off
DCBMWizard, why can I only scan line A on each DALI power supply DCDALCIP250-2 using the DCCABKIT6 programming cable?
Hide ShowConfirmed that DCBMwizard can only connect to LineA
To connect to LineB
1) You can remove LineA and move LineB to LineA. Once commission is completed you can rewire it back.
2) or having a secondary DCCABKIT6 programming cable as line B is powered by line A
What colours are the new Iconic Outdoor Products available in?
Hide ShowVIDEO - How to set up communication between a M251 PLC and HMIGTO via serial
Hide ShowWhat is the cut out size for Z4025, Zen series double outlet?
Hide ShowPlease go to the following links below and check under the Documentation Tab for more information.
Australia - https://www.clipsal.com/products/detail?CatNo=Z4025&itemno=Z4025-ZW&backto=/search?q=Z4025&tab-document-1=0
New Zealand - https://www.pdl.co.nz/products/detail?CatNo=Z4025&itemno=Z4025-ZW&backto=/search?q=Z4025&tab-document-1=0
What is the coil tolerance for Tesys D-line contactors LC1D09 - LC1D38?
Hide ShowLC1D09 - LC1D38 Coil tolerance
Product Line:
Contactors and Starters, IEC
Environment:
Tesys D Contactors
Cause:
Needs the coil tolerance for Tesys D-line contactors LC1D09 - LC1D38.
Resolution:
AC single frequency coils: 50Hz and 60 Hz (-20% / +10%);
AC dual frequency coils: 50Hz (-20% / +10%) ; 60Hz (-15% / +10%)
DC standard coil for LC1D09 -D38 and LC1DT20 to DT40: (-30% / +25%)
DC standard coil for LP1D12 and D25: (-20% / +10%)
DC wide range coil for LP1D12 and D25 : (-30% to +25%)