Standard Series Flush Switch 3 Gang, 250VAC, 10A, Architrave | Cream
Item Number: 33A-CM
Datasheet
Specifications
Design
Range of product
Product brand
Physical
Device presentation
Number of poles
Device mounting
Number of rocker
Local signalling
[ue] rated operational voltage
Rated current
Marking
Fixing mode
Actuator
Switch function
Eu rohs directive
Mercury free
Rohs exemption information
China rohs regulation
Environmental disclosure
Circularity profile
Others
Commercial status history
- SESA301466
- Wed Sep 27 02:54:00 EDT 2023
- From Import Local
- From 18 to 19
Package 1 bare product quantity
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Unit type of package 2
Number of units in package 2
Package 2 height
Package 2 width
Package 2 length
Package 2 weight
Package 3 height
Documents & downloads
hide show-
All
-
Technical Data Catalogues
-
Certificates (MSDS)
Frequently Asked Questions
Why is the LCD display screen blank on a Micrologic Power or Harmonic type trip unit on a Powerpact P frame, R frame, or Masterpact circuit breaker?
Hide ShowWhy is the display blank on the trip unit?
Product Line:
Powerpact P frame, Powerpact R Frame, Masterpact NT, Masterpact NW
Resolution:
The LCD display on a Micrologic P or H trip unit will be blank unless the trip unit is energized. Energization requires one of the following sets of conditions:
- The trip unit is energized by an external 24 Vdc applied to terminals F1-F2 (F1 negative-F2 positive). See attachment for location of terminals.
- The trip unit is energized by an FFTK or HHTK test kit
- There is at least 100 V between two phases, AND the load reaches approximately 20% of the breaker's rated current.
- Note that the display will not power up with primary injection testing unless one of the conditions in bullet 1 above is met.
- Note that Ammeter trip units do not require external power and the display will come on with sufficient current flow alone.
Video: What are the part numbers for field replaceable Micrologic trip units for PowerPact™ M,P,R, and Masterpact NT, NW circuit breakers?
Hide ShowCircuit Breakers
Resolution:
Following are the catalog numbers for Micrologic Trip Units used in PowerPact™ M, P, R, and Masterpact NT and NW circuit breakers.
Model | Protection | Cat. # |
2.0 (IEC only) | LSO | S132R |
3.0 (UL/ANSI only) | LI | S131A |
5.0 | LSI | S133A |
2.0A (IEC only) | LSO | S142R |
3.0A (UL/ANSI only) | LI | S141A |
5.0A | LSI | S143A |
6.0A | LSIG | S144A |
5.0P | LSI | S163A |
6.0P | LSIG | S164A |
5.0H | LSI | S173A |
6.0H | LSIG | S174A |
For help with Micrologic trip units and modbus communications for Masterpact and PowerPact™ P and R circuit breakers, consult instruction manuals:
PowerPact™ P, R, and Masterpact NW, NT Micrologic™ types 2.0, 3.0 and 5.0 Trip Units, see 48049-207-05
PowerPact™ P, R, and Masterpact NW, NT Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0A Trip Units, see 48049-136-05
PowerPact™ P, R, and Masterpact NW, NT Micrologic™ 5.0P and 6.0P Trip Units, see 48049-137-05
PowerPact™ P, R, and Masterpact NW, NT Micrologic™ 5.0H and 6.0H Trip Units, see 48049-330-03
The following video demonstrates how to install and remove a Micrologic Trip Unit from a PowerPact™ P-Frame Molded Case Circuit Breaker: