Standard Series Flush Switch 3 Gang, 250VAC, 10A, Architrave

Standard Series Flush Switch 3 Gang, 250VAC, 10A, Architrave | Black

Item Number: 33A-BK

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Standard Series

Product brand

Clipsal

Physical

Device presentation

basic element with full cover plate

Number of poles

1

Device mounting

flush

Number of rocker

3

Local signalling

without

[ue] rated operational voltage

250 V AC

Rated current

10 A

Marking

without marking

Fixing mode

by screws

Actuator

rocker

Switch function

1-pole

Eu rohs directive

Compliant with Exemptions

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental disclosure

ENVPEP120506EN

Circularity profile

N/A

Others

Commercial status history

  • SESA301466
  • Wed Sep 27 02:54:00 EDT 2023
  • From Import Local
  • From 18 to 19

Package 1 bare product quantity

1

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

3 cm

Package 1 width

3.2 cm

Package 1 length

11.3 cm

Package 1 weight

60.7 g

Unit type of package 2

BB1

Number of units in package 2

10

Package 2 height

11.7 cm

Package 2 width

10.2 cm

Package 2 length

13.8 cm

Package 2 weight

0.68 kg

Package 3 height

15.7 cm
Show all specifications

Documents & downloads

hide show

Frequently Asked Questions

Why is the LCD display screen blank on a Micrologic Power or Harmonic type trip unit on a Powerpact P frame, R frame, or Masterpact circuit breaker?

Hide Show
Issue:
Why is the display blank on the trip unit?

Product Line:
Powerpact P frame, Powerpact R Frame, Masterpact NT, Masterpact NW

Resolution:
The LCD display on a Micrologic P or H trip unit will be blank unless the trip unit is energized.  Energization requires one of the following sets of conditions:
  1. The trip unit is energized by an external 24 Vdc applied to terminals F1-F2 (F1 negative-F2 positive).  See attachment for location of terminals.
  2. The trip unit is energized by an FFTK or HHTK test kit
  3. There is at least 100 V between two phases, AND the load reaches approximately 20% of the breaker's rated current.
  • Note that the display will not power up with primary injection testing unless one of the conditions in bullet 1 above is met.
  • Note that Ammeter trip units do not require external power and the display will come on with sufficient current flow alone.
See the following bulletins for more information on these trip units.
 

Video: What are the part numbers for field replaceable Micrologic trip units for PowerPact™ M,P,R, and Masterpact NT, NW circuit breakers?

Hide Show
Product Line:
Circuit Breakers

Resolution:
Following are the catalog numbers for Micrologic Trip Units used in PowerPact™ M, P, R, and Masterpact NT and NW circuit breakers.
 
ModelProtectionCat. #
2.0 (IEC only)LSOS132R
3.0 (UL/ANSI only) LIS131A
5.0LSIS133A
2.0A (IEC only)LSOS142R 
3.0A (UL/ANSI only) LIS141A 
5.0ALSIS143A 
6.0ALSIGS144A 
5.0PLSIS163A
6.0PLSIGS164A
5.0HLSIS173A
6.0HLSIGS174A


For help with Micrologic trip units and modbus communications for Masterpact and PowerPact™ P and R circuit breakers, consult instruction manuals:
PowerPact™ P, R, and Masterpact NW, NT Micrologic™ types 2.0, 3.0 and 5.0 Trip Units, see 48049-207-05
PowerPact™ P, R, and Masterpact NW, NT Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0A Trip Units, see 48049-136-05
PowerPact™ P, R, and Masterpact NW, NT Micrologic™ 5.0P and 6.0P Trip Units, see 48049-137-05
PowerPact™ P, R, and Masterpact NW, NT Micrologic™ 5.0H and 6.0H Trip Units, see 48049-330-03

The following video demonstrates how to install and remove a Micrologic Trip Unit from a PowerPact™ P-Frame Molded Case Circuit Breaker:

 
 

What is the part number for a mounting block to suit a C2033A?

Hide Show
Unfortunately there is no mounting block for this product.