Standard Series Flush Plates - Standard Series Architrave Size, Switch Plate 2 Gang (75 x 32mm) | White Electric
Item Number: 32-WE
Datasheet
Specifications
Design
| Range of product | Standard Series |
|---|---|
| Product brand | Clipsal |
| Product destination | switch |
Physical
| Fixing mode | by screws |
|---|---|
| Marking | without marking |
| Mounting position | horizontal and vertical |
| Fixing center | 70 mm |
| Length | 86 mm |
| Width | 32 mm |
| Depth | 11 mm |
| Number of gangs | 2 gangs |
| Mercury free | Yes |
| Rohs exemption information | Yes |
| Environmental disclosure | ENVPEP2103014_V1 |
| Reach regulation | Reference contains Substances of Very High Concern above the threshold |
| China rohs regulation | Product out of China RoHS scope |
| Eu rohs directive | Compliant By Exemption |
Material
| Material | plastic |
|---|
Documents & downloads
-
All
-
Technical Data Catalogues
-
Declaration of Conformity (Sustainability)
Frequently Asked Questions
Does C-gate3 run on window 32 or 64 bit?
Hide ShowC-Gate 3 and C-Bus Commission are both 64bit applications which require a 64bit Operating System on a 64 bit Processor to run.
How to Enable +/- Speeds Around Preset Speeds on ATV320 Drive
Hide ShowIt is possible to set preset speeds on the ATV320 drive and also allow for manual speed adjustments above and below those presets. Please refer to the steps below.
- Set desired preset speeds in [PRESET SPEEDS] menu as shown.
RDY -> CONF -> FULL -> LAC -> Epr (Expert)
RDY-> CONF -> FULL -> Fun [Application Function] -> PSS - [Preset Speeds]
- Set up desired values for speed around reference in [SPEED AROUND REFERENCE] menu.
RDY -> CONF -> FULL -> Fun [Application Function] -> SrE (menu shown below)
Example:
Setting Access level to Expert access.
Assigning Digital Inputs 2 and 3 to control preset speeds (enabling up to three preset speeds)
Preset Speeds 2, 3, and 4 configured to 14 Hz, 18 Hz, and 22 Hz respectively.
Setting Digital input 4 for increase in speed (+).
Setting Digital input 5 for decrease in speed (-).
A +/- speed variation limit of 13% has been applied, restricting any increase or decrease from the preset speed to a maximum of 13%.
Acceleration and deceleration time for changing speed set to 5s.
How do you distribute MAXBAR from the main row to other rows, keeping the system more professional?
Hide ShowWhat has been changed with the new Rotary LED dimmers for Iconic range (40 series) and standard range (30 series)?
Hide ShowBoth dimmers have now been improved and introduce the following new features
- New Digital electronic 2-wire trailing edge design for optimum LED dimming performance
- Kick start for faster LED turn on at low settings
- Mechanically adjustable minimum brightness setting
- In-built short circuit, over current and over temperature protection
- Full range smooth LED dimming from 1 – 100% (load dependant)
- Cleaner look with no markings on the control knobs
Please note that the load ratings have changed for the new version. The new 32ELEDM2-WE and 42ELEDM2-VW are rated to 150W to enable enhanced LED optimised control and dimming performance.
What is MAXBAR?
Hide ShowThere are Comb busbar for 1P+N and 3P+N applications. There is one variant with neutral terminal block for rows with Main Switch and another variant for rows without Main switch.
How can MAXBAR help me to save time during switchboard installation ?
Hide ShowHow is an Altivar VFD set to always run a particular speed when no reference input is connected?
Hide ShowWants the Altivar VFD set to always run at a particular speed when no reference input is connected.
Product Line:
Altivar 12, 32, 312, 61, 71, 212, 320
Environment:
All models
Cause:
VFD does not run the motor without a speed reference.
Resolution:
If there is no external speed reference when the VFD gets a run command, then it will always run at the minimum speed programmed to the VFD. Set the minimum speed parameter to the desired run speed. Use parameter LSP for the Altivar12, 32, 312, 320, 61, 71 drives. Use parameter LL for the Altivar 212 drive. These can be adjusted while the motor is running.