Standard Series Flush Plates - Standard Series Architrave Size, Switch Plate 2 Gang (75 x 32mm) | Black
Item Number: 32-BK
Datasheet
Specifications
Design
| Range of product | Standard Series |
|---|---|
| Product brand | Clipsal |
| Product destination | switch |
Physical
| Fixing mode | by screws |
|---|---|
| Marking | without marking |
| Mounting position | horizontal and vertical |
| Fixing center | 70 mm |
| Length | 86 mm |
| Width | 32 mm |
| Depth | 11 mm |
| Number of gangs | 2 gangs |
| Mercury free | Yes |
| Rohs exemption information | Yes |
| Environmental disclosure | ENVPEP2103014_V1 |
| Eu rohs directive | Compliant By Exemption |
Material
| Material | plastic |
|---|
Documents & downloads
-
All
-
Technical Data Catalogues
-
Declaration of Conformity (Sustainability)
Frequently Asked Questions
VAMPSET tool error: "This VAMP device requires VAMPSET version 2.2.210 or higher for configuration. I cannot find this version on the website. How can I obtain it?"
Hide ShowIssue:
VAMPSET tool error:"This VAMP device requires VAMPSET version 2.2.210 or higher for configuration. I cannot find this version on the website. How can I obtain it?"
Product Line:
V321 Protection Relay, Easergy Pro Tool , VAMPSET Tool
Environment:
VAMP321 relay configuration and communication software
Resolution:
The message is expected behavior for certain VAMP321 firmware versions. Although the relay requests VAMPSET version 2.2.210 or higher, this software version is generally no longer available for public download.
The VAMP321 is part of the VAMP protection relay family, which historically used VAMPSET as the engineering and configuration software. Most VAMP relay models have since reached the end of their production lifecycle, while the VAMP321 continues to be maintained and supported.
As part of the product evolution, Schneider Electric migrated VAMP321 configuration support from VAMPSET to Easergy Pro. Software compatibility depends on the relay firmware version:
- Older VAMP321 firmware versions are configured using VAMPSET.
- Firmware version 20.116 and later should be configured using Easergy Pro.
Based on testing performed with VAMP321 devices, it is normal to encounter situations where:
- An older VAMP321 communicates only through VAMPSET.
- A newer VAMP321 requires Easergy Pro for communication and configuration.
Therefore, if your VAMP321 is running firmware 20.116 or later, Schneider Electric recommends using Easergy Pro instead of searching for VAMPSET 2.2.210.
Additionally, it is recommended to use the latest available version of Easergy Pro, as earlier releases had known communication issues with some VAMP321 devices that were resolved in later versions.
Latest Easergy Pro downloads are available at:
https://www.se.com/au/en/product-range/63736-esetup-easergy-pro/#software-and-firmware
If the relay is running an older firmware version that genuinely requires VAMPSET, and the required VAMPSET version cannot be found on the public website, contact Schneider Electric Technical Support for assistance in identifying the correct engineering tool and software package.
Why are 9001KM38 listed twice, as resistor and full voltage light modules?
Hide ShowIs the 9001KM38 a resistor type or full voltage type of light module?
Product Line:
Push Buttons and Operator Interface
Environment:
Harmony Pushbuttons
Cause:
Product Features
Resolution:
Both descriptions are accurate. They are both the same device but can be selected by either description depending on the application/preference.
What has been changed with the new Rotary LED dimmers for Iconic range (40 series) and standard range (30 series)?
Hide ShowBoth dimmers have now been improved and introduce the following new features
- New Digital electronic 2-wire trailing edge design for optimum LED dimming performance
- Kick start for faster LED turn on at low settings
- Mechanically adjustable minimum brightness setting
- In-built short circuit, over current and over temperature protection
- Full range smooth LED dimming from 1 – 100% (load dependant)
- Cleaner look with no markings on the control knobs
Please note that the load ratings have changed for the new version. The new 32ELEDM2-WE and 42ELEDM2-VW are rated to 150W to enable enhanced LED optimised control and dimming performance.
Does C-gate3 run on window 32 or 64 bit?
Hide ShowC-Gate 3 and C-Bus Commission are both 64bit applications which require a 64bit Operating System on a 64 bit Processor to run.
How to Enable +/- Speeds Around Preset Speeds on ATV320 Drive
Hide ShowIt is possible to set preset speeds on the ATV320 drive and also allow for manual speed adjustments above and below those presets. Please refer to the steps below.
- Set desired preset speeds in [PRESET SPEEDS] menu as shown.
RDY -> CONF -> FULL -> LAC -> Epr (Expert)
RDY-> CONF -> FULL -> Fun [Application Function] -> PSS - [Preset Speeds]
- Set up desired values for speed around reference in [SPEED AROUND REFERENCE] menu.
RDY -> CONF -> FULL -> Fun [Application Function] -> SrE (menu shown below)
Example:
Setting Access level to Expert access.
Assigning Digital Inputs 2 and 3 to control preset speeds (enabling up to three preset speeds)
Preset Speeds 2, 3, and 4 configured to 14 Hz, 18 Hz, and 22 Hz respectively.
Setting Digital input 4 for increase in speed (+).
Setting Digital input 5 for decrease in speed (-).
A +/- speed variation limit of 13% has been applied, restricting any increase or decrease from the preset speed to a maximum of 13%.
Acceleration and deceleration time for changing speed set to 5s.
How do you distribute MAXBAR from the main row to other rows, keeping the system more professional?
Hide ShowWhat is MAXBAR?
Hide ShowThere are Comb busbar for 1P+N and 3P+N applications. There is one variant with neutral terminal block for rows with Main Switch and another variant for rows without Main switch.