Browse all
Browse all

Zelio Logic Discrete I/O extension module 6 I/O, 100...240V AC

Home ProductsIndustrialZelio LogicDiscrete I/O extension module

Zelio Logic Discrete I/O extension module 6 I/O, 100...240V AC

Item Number: SR3XT61FU

This Zelio Logic SR3 discrete I/O extension module smart relays uses a supply voltage of 100V-240V alternating current. It has 6 inputs / outputs contact with screw-clamp terminals. It enables simple ladder programming, adapted for non-specialists.

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product Zelio Logic
Product or component type discrete I/O extension module
Warranty 18 months

Physical

Backup time 10 years at 25 °C
Electrical durability
  • AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to IEC 60947-5-1
  • AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to IEC 60947-5-1
  • DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to IEC 60947-5-1
  • DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to IEC 60947-5-1
Mechanical durability 10000000 cycles for relay output
Connections - terminals
  • screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
  • screw terminals, 2 x 0.25...2 x 0.75 mm² (AWG 24...AWG 18) flexible with cable end
  • screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) semi-solid
  • screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) solid
  • screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) solid
Net weight 0.125 kg
Product certifications
  • CSA
  • GOST
  • C-Tick
  • UL
  • GL
Standards
  • IEC 61000-4-11
  • IEC 60068-2-27 Ea
  • IEC 61000-4-4 level 3
  • IEC 61000-4-5
  • IEC 61000-4-12
  • IEC 60068-2-6 Fc
  • IEC 61000-4-2 level 3
  • IEC 61000-4-3
  • IEC 61000-4-6 level 3
Ip degree of protection
  • IP20 (terminal block) conforming to IEC 60529
  • IP40 (front panel) conforming to IEC 60529
Environmental characteristic
  • EMC directive conforming to IEC 61000-6-2
  • EMC directive conforming to IEC 61000-6-3
  • EMC directive conforming to IEC 61000-6-4
  • EMC directive conforming to IEC 61131-2 zone B
  • low voltage directive conforming to IEC 61131-2
Ambient air temperature for operation
  • -20...40 °C in non-ventilated enclosure conforming to IEC 60068...2-1 and IEC 60068...2-2
  • -20...55 °C conforming to IEC 60068...2-1 and IEC 60068...2-2
Ambient air temperature for storage -40...70 °C
Relative humidity 95 % without condensation or dripping water
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP2011013EN
Reach regulation Reference contains Substances of Very High Concern above the threshold
China rohs regulation X
Eu rohs directive Compliant By Exemption
California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Others

Package 2 bare product quantity 48
Average percentage of recycled plastic content 0 %
Package 1 bare product quantity 1
Legacy weee scope In
Warranty duration(in months) bmecat 18
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
At least in Europe
Number or control scheme lines 120 with ladder programming
Cycle time 6...90 ms
Clock drift 12 min/year at 0-55 °C
Checks program memory on each power up
[us] rated supply voltage 100...240 V AC
Supply voltage limits 85...264 V
Supply frequency 50/60 Hz
Reverse polarity protection with
Discrete input number 4
Discrete input voltage 100...240 V AC
Discrete input current 0.6 mA
Discrete input frequency
  • 57...63 Hz
  • 47...53 Hz
Voltage state 1 guaranteed >= 79 V for discrete input
Voltage state 0 guaranteed <= 40 V for discrete input
Current state 1 guaranteed >= 0.17 mA (discrete input)
Current state 0 guaranteed <= 0.5 mA (discrete input)
Input impedance 350 kOhm for discrete input
Number of outputs 2 relay
Output voltage limits
  • 5...30 V DC (relay output)
  • 24...250 V AC
Contacts type and composition NO for relay output
Output thermal current 8 A for all 2 outputs for relay output
Switching capacity in ma >= 10 mA at 12 V (relay output)
Operating rate in hz
  • 0.1 Hz (at Ie) for relay output
  • 10 Hz (no load) for relay output
[uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
Response time
  • 50 ms with ladder programming (from state 0 to state 1) for discrete input
  • 50 ms with ladder programming (from state 1 to state 0) for discrete input
  • 50...255 ms with FBD programming (from state 0 to state 1) for discrete input
  • 50...255 ms with FBD programming (from state 1 to state 0) for discrete input
  • 10 ms (from state 0 to state 1) for relay output
  • 5 ms (from state 1 to state 0) for relay output
Tightening torque 0.5 N.m
Overvoltage category III conforming to IEC 60664-1
Disturbance radiated/conducted class B conforming to EN 55022-11 group 1
Pollution degree 2 conforming to IEC 61131-2
Operating altitude 2000 m
Maximum altitude transport 3048 m
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 6.000 cm
Package 1 width 6.500 cm
Package 1 length 11.000 cm
Package 1 weight 118.000 g
Unit type of package 2 S03
Number of units in package 2 48
Package 2 height 30.000 cm
Package 2 width 30.000 cm
Package 2 length 40.000 cm
Package 2 weight 6.149 kg
Green premium status for reporting Green Premium product
Total lifecycle carbon footprint 101 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 14.9756558824
Carbon footprint of the manufacturing phase [a1 to a3] 15 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.0150957529
Carbon footprint of the distribution phase [a4] 0 kg CO2 eq.
Carbon footprint of the installation phase [a5] 0.0008631847
Carbon footprint of the installation phase [a5] 0 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 85.84
Carbon footprint of the use phase [b2, b3, b4, b6] 86 kg CO2 eq.
Sustainable packaging Yes
Carbon footprint of the end-of-life phase [c1 to c4] 0.0923990294
Carbon footprint of the end-of-life phase [c1 to c4] 0.1 kg CO2 eq.
Pvc free Yes
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 100.9240138494
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard Yes
Packaging without single use plastic Yes
Scip number ab7a5df6-4d23-4fb1-96de-7c15d64130aa
China rohs label 5
Pvc free Yes
End of life manual availability ENVEOLI2011013EN
Take-back No
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Installation Instruction

  • Environmental Disclosure

  • End of Life Manual

  • Operating Manuals

  • Technical illustration

  • Certificates (MSDS)

  • Declaration of Conformity

  • eTechPub

  • Declaration of Conformity (Sustainability)

  • Software - Release

Important: Some software files may need a mySchneider or Club login to download.