| Life cycle assessment data |
Yes |
| Substance regulation data deliverable |
Yes |
| Legacy weee scope |
In |
| Package 1 bare product quantity |
1 |
| Average percentage of recycled plastic content |
0 % |
| |
At least in Europe |
| Warranty duration(in months) bmecat |
18 |
| Weee label |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Weee applicability |
Finished product |
| Device short name |
GV4P |
| Product name |
TeSys GV4 |
| Trip unit technology |
- thermal-magnetic
- electronic
|
| Poles description |
3P |
| Utilisation category |
- category A conforming to IEC 60947-2
- AC-3 conforming to IEC 60947-4-1
|
| Operating position |
any position |
| Motor power kw |
- 1.5...1.5 kW at 400...415 V AC 50/60 Hz
- 2.2.2 kW at 400...415 V AC 50/60 Hz
- 2.5...2.5 kW at 400...415 V AC 50/60 Hz
- 3 kW at 400...415 V AC 50/60 Hz
- 2.2.2 kW at 500 V AC 50/60 Hz
- 2.5...2.5 kW at 500 V AC 50/60 Hz
- 3 kW at 500 V AC 50/60 Hz
- 4 kW at 500 V AC 50/60 Hz
- 3 kW at 660...690 V AC 50/60 Hz
- 4 kW at 660...690 V AC 50/60 Hz
- 5.5.5 kW at 660...690 V AC 50/60 Hz
- 7.5...7.5 kW at 660...690 V AC 50/60 Hz
|
| Breaking capacity |
- 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
- 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
- 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
- 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
- 65 kA at 208Y/120 V AC 50/60 Hz conforming to UL 60947
- 65 kA at 240 V AC 50/60 Hz conforming to UL 60947
- 35 kA at 480Y/277 V AC 50/60 Hz conforming to UL 60947
- 8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
- 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
- 18 kA at 600Y/347 V AC 50/60 Hz conforming to UL 60947
|
| Magnetic tripping current |
119 A |
| [ui] rated insulation voltage |
800 V AC 50/60 Hz conforming to IEC 60947-2 |
| [ith] conventional free air thermal current |
115 A conforming to IEC 60947-4-1 |
| [uimp] rated impulse withstand voltage |
8 kV conforming to IEC 60947-2 |
| Power dissipation per pole |
4.6 W |
| Maximum operating rate |
25 cyc/h |
| Rated duty |
continuous conforming to IEC 60947-4-1 |
| Connection pitch |
- 27 mm without spreaders
- 35 mm with spreaders
|
| Direct connector |
without |
| Tightening torque |
- 9 N.m for cable 16-95 mm²
- 5 N.m for cable 1.5-10 mm²
|
| Mechanical robustness |
- vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6
- vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6
- shocks: 15 gn 11 ms conforming to IEC 60068-2-27
|
| Phase failure sensitivity |
yes conforming to IEC 60947-4-1 |
| Suitability for isolation |
yes conforming to IEC 60947-1 |
| Pollution degree |
3 |
| Fire resistance |
960 °C conforming to IEC 60695-2-11 |
| Operating altitude |
5000 m |
| Unit type of package 1 |
PCE |
| Number of units in package 1 |
1 |
| Package 1 height |
11.000 cm |
| Package 1 width |
21.000 cm |
| Package 1 length |
22.000 cm |
| Package 1 weight |
1.695 kg |
| Unit type of package 2 |
S03 |
| Number of units in package 2 |
3 |
| Package 2 height |
30.000 cm |
| Package 2 width |
30.000 cm |
| Package 2 length |
40.000 cm |
| Package 2 weight |
5.470 kg |
| Unit type of package 3 |
P06 |
| Number of units in package 3 |
24 |
| Package 3 height |
75.000 cm |
| Package 3 width |
80.000 cm |
| Package 3 length |
60.000 cm |
| Package 3 weight |
51.760 kg |
| Green premium status for reporting |
Green Premium product |
| Total lifecycle carbon footprint |
91 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [a1 to a3] |
11.889032401199032 |
| Carbon footprint of the manufacturing phase [a1 to a3] |
12 kg CO2 eq. |
| Carbon footprint of the distribution phase [a4] |
0.502764933926811 |
| Carbon footprint of the distribution phase [a4] |
0.5 kg CO2 eq. |
| Carbon footprint of the installation phase [a5] |
0.4480353851071321 |
| Carbon footprint of the installation phase [a5] |
0.4 kg CO2 eq. |
| Carbon footprint of the use phase [b2, b3, b4, b6] |
74.322 |
| Carbon footprint of the use phase [b2, b3, b4, b6] |
74 kg CO2 eq. |
| Sustainable packaging |
No |
| Carbon footprint of the end-of-life phase [c1 to c4] |
4.051351533859914 |
| Carbon footprint of the end-of-life phase [c1 to c4] |
4 kg CO2 eq. |
| Pvc free |
Yes |
| Energy efficiency optimized |
False |
| F-gas free |
N/A |
| Updatability |
N/A |
| Take-back |
No |
| Product contributes to saved and avoided emissions |
No |
| Removable battery |
N/A |
| Total lifecycle carbon footprint |
91.2131842540929 |
| Average percentage of recycled metal content |
0 % |
| Packaging made with recycled cardboard |
Yes |
| Packaging without single use plastic |
Yes |
| Scip number |
1b259a2c-3a3c-401a-acdd-f0837efd4018 |
| Pvc free |
Yes |
| End of life manual availability |
ENVEOLI1704004EN |
| Take-back |
No |
| Weee label |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty (in months) |
18 |