| Life cycle assessment data |
Yes |
| Substance regulation data deliverable |
Yes |
| Legacy weee scope |
In |
| |
At least in Europe |
| Average percentage of recycled plastic content |
0 % |
| Package 3 bare product quantity |
320 |
| Package 2 bare product quantity |
20 |
| Package 1 bare product quantity |
1 |
| Warranty duration(in months) bmecat |
18 |
| Weee label |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Product name |
TeSys CAD |
| Device short name |
CAD |
| Contactor application |
control circuit |
| Utilisation category |
|
| Pole contact composition |
3 NO + 2 NC |
| Control circuit type |
AC at 50/60 Hz |
| [uc] control circuit voltage |
240 V AC 50/60 Hz |
| [uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947 |
| [ith] conventional free air thermal current |
10 A (at 60 °C) |
| Irms rated making capacity |
- 140 A AC conforming to IEC 60947-5-1
- 250 A DC conforming to IEC 60947-5-1
|
| [icw] rated short-time withstand current |
- 100 A - 1 s
- 120 A - 500 ms
- 140 A - 100 ms
|
| Associated fuse rating |
10 A gG conforming to IEC 60947-5-1 |
| [ui] rated insulation voltage |
- 600 V UL certified
- 600 V CSA certified
- 690 V conforming to IEC 60947-5-1
|
| Tightening torque |
- 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
- 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
- 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
|
| Control circuit voltage limits |
- 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz
- 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz
- 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz
- 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
|
| Operating time |
- 12...22 ms coil energisation and NO closing
- 4...12 ms coil de-energisation and NO opening
- 4...19 ms coil energisation and NC opening
- 6...17 ms coil de-energisation and NC closing
|
| Maximum operating rate |
180 cyc/mn |
| Inrush power in va |
70 VA 50 Hz (at 20 °C) |
| Hold-in power consumption in va |
8 VA 50 Hz (at 20 °C) |
| Minimum switching voltage |
17 V |
| Minimum switching current |
5 mA |
| Non-overlap time |
- 1.5 ms on energisation between NC and NO contact
- 1.5 ms on de-energisation between NC and NO contact
|
| Mechanical robustness |
- shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27
- shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27
- vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
- vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
|
| Compatibility code |
CAD |
| Protective treatment |
TH conforming to IEC 60068 |
| Operating altitude |
0...3000 m |
| Unit type of package 1 |
PCE |
| Number of units in package 1 |
1 |
| Package 1 height |
5.000 cm |
| Package 1 width |
9.200 cm |
| Package 1 length |
11.200 cm |
| Package 1 weight |
344.000 g |
| Unit type of package 2 |
S02 |
| Number of units in package 2 |
20 |
| Package 2 height |
15.000 cm |
| Package 2 width |
30.000 cm |
| Package 2 length |
40.000 cm |
| Package 2 weight |
7.195 kg |
| Unit type of package 3 |
P06 |
| Number of units in package 3 |
320 |
| Package 3 height |
75.000 cm |
| Package 3 width |
60.000 cm |
| Package 3 length |
80.000 cm |
| Package 3 weight |
125.696 kg |
| Green premium status for reporting |
Green Premium product |
| Total lifecycle carbon footprint |
18 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [a1 to a3] |
2.4052974453589133 |
| Carbon footprint of the manufacturing phase [a1 to a3] |
2 kg CO2 eq. |
| Carbon footprint of the distribution phase [a4] |
0.2688271654154445 |
| Carbon footprint of the distribution phase [a4] |
0.3 kg CO2 eq. |
| Carbon footprint of the installation phase [a5] |
0.09473546449819852 |
| Carbon footprint of the installation phase [a5] |
0.1 kg CO2 eq. |
| Carbon footprint of the use phase [b2, b3, b4, b6] |
15.364183683872902 |
| Carbon footprint of the use phase [b2, b3, b4, b6] |
15 kg CO2 eq. |
| Sustainable packaging |
No |
| F-gas free |
N/A |
| Take-back |
No |
| Product contributes to saved and avoided emissions |
No |
| Removable battery |
N/A |
| Total lifecycle carbon footprint |
18.13304375914546 |
| Average percentage of recycled metal content |
0 % |
| Packaging made with recycled cardboard |
Yes |
| Packaging without single use plastic |
Yes |
| Scip number |
b67ac941-f42f-4afd-894a-0b6f9cefde62 |
| End of life manual availability |
ENVEOLI1501004 |
| Take-back |
No |
| Weee label |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty (in months) |
18 |