TeSys D Contactor TeSys Deca, 4P(4 NO), AC-1, 0 to 440V, 40A, 48VDC standard coil
Item Number: LC1DT40ED
Datasheet
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| - | |||
| - | |||
| - |
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| 1 | CAR | 3389110247862 | - |
Specifications
Design
| Range |
|
|---|---|
| Range of product | TeSys Deca |
| Product or component type | contactor |
| Warranty | 18 months |
Physical
| [ue] rated operational voltage |
|
|---|---|
| [ie] rated operational current | 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
| Mechanical durability | 30 Mcycles |
| Electrical durability | 1.4 Mcycles 40 A AC-1 at Ue <= 440 V |
| Connections - terminals |
|
| Insulation resistance | > 10 MOhm for signalling circuit |
| Mounting support |
|
| Connections - terminals | screw clamp terminals |
| Standards |
|
| Product certifications |
|
| Ip degree of protection | IP20 front face conforming to IEC 60529 |
| Climatic withstand |
|
| Height | 91 mm |
| Width | 45 mm |
| Depth | 107 mm |
| Net weight | 0.425 kg |
| Toxic heavy metal free | Yes |
| Mercury free | Yes |
| Rohs exemption information | Yes |
| Environmental disclosure | ENVPEP110230EN |
| Reach regulation | Reference contains Substances of Very High Concern above the threshold |
| China rohs regulation | Product out of China RoHS scope |
| Eu rohs directive | Compliant |
| California proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Others
| Legacy weee scope | In |
|---|---|
| Substance regulation data deliverable | Yes |
| Life cycle assessment data | Yes |
| At least in Europe | |
| Package 1 bare product quantity | 1 |
| Average percentage of recycled plastic content | 0 % |
| Warranty duration(in months) bmecat | 18 |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Device short name | LC1D |
| Contactor application | resistive load |
| Utilisation category | AC-1 |
| Poles description | 4P |
| [uc] control circuit voltage | 48 V DC |
| Compatibility code | LC1D |
| Pole contact composition | 4 NO |
| Protective cover | with |
| [ith] conventional free air thermal current |
|
| Irms rated making capacity |
|
| Rated breaking capacity | 450 A at 440 V for power circuit conforming to IEC 60947 |
| [icw] rated short-time withstand current |
|
| Associated fuse rating |
|
| Average impedance | 2 mOhm - Ith 40 A 50 Hz for power circuit |
| Power dissipation per pole | 3.2 W AC-1 |
| [ui] rated insulation voltage |
|
| Overvoltage category | III |
| Pollution degree | 3 |
| [uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level |
|
| Control circuit type | DC standard |
| Coil technology | built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits |
|
| Inrush power in w | 5.4...5.4 W (at 20 °C) |
| Hold-in power consumption in w | 5.4...5.4 W at 20 °C |
| Operating time |
|
| Time constant | 28 ms |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Tightening torque |
|
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type |
|
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Non-overlap time |
|
| Contact compatibility | M7 |
| [uc] control circuit voltage | 48 V |
| Rated thermal current (ith) | 40 A |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Permissible ambient air temperature around the device |
|
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness |
|
| Unit type of package 1 | PCE |
| Number of units in package 1 | 1 |
| Package 1 height | 12.300 cm |
| Package 1 width | 10.700 cm |
| Package 1 length | 5.400 cm |
| Package 1 weight | 633.000 g |
| Green premium status for reporting | Green Premium product |
| Total lifecycle carbon footprint | 55 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [a1 to a3] | 3.191586354285151 |
| Carbon footprint of the manufacturing phase [a1 to a3] | 3 kg CO2 eq. |
| Carbon footprint of the distribution phase [a4] | 0.17639309647678564 |
| Carbon footprint of the distribution phase [a4] | 0.2 kg CO2 eq. |
| Carbon footprint of the installation phase [a5] | 0.04884624271288673 |
| Carbon footprint of the installation phase [a5] | 0 kg CO2 eq. |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 50.33556756756758 |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 50 kg CO2 eq. |
| Sustainable packaging | Yes |
| Carbon footprint of the end-of-life phase [c1 to c4] | 1.5456550019145097 |
| Carbon footprint of the end-of-life phase [c1 to c4] | 2 kg CO2 eq. |
| Pvc free | Yes |
| F-gas free | N/A |
| Take-back | No |
| Product contributes to saved and avoided emissions | No |
| Removable battery | N/A |
| Total lifecycle carbon footprint | 55.29804826295691 |
| Average percentage of recycled metal content | 0 % |
| Packaging made with recycled cardboard | Yes |
| Packaging without single use plastic | Yes |
| Scip number | 50ae7612-fd2e-41e4-a369-50d0dea6e592 |
| China rohs label | 1 |
| Pvc free | Yes |
| End of life manual availability | ENVEOLI1102030EN |
| Take-back | No |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty (in months) | 18 |
Documents & downloads
-
All
-
CAD Files and Packs
-
Technical Data Catalogues
-
Environmental Disclosure
-
End of Life Manual
-
Data Bulletin
-
Installation Instruction
-
Technical illustration
-
Certificates (MSDS)
-
Declaration of Conformity
-
Declaration of Conformity (Sustainability)
UL_Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40_DPE_DC_Coils
VERSION
1.0
DATE
24 Apr 2026
REVISION
1.0
CCC_TeSys Deca_LC1D188-258&LC1DT32-DT40&LC2DT32-DT40_Batam
VERSION
1.0
DATE
08 Apr 2026
REVISION
1.0
CSA Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40_DPE
VERSION
1.0
DATE
06 Nov 2025
REVISION
1.0
CCC_TeSys Deca_LC1D188-258&LC1DT32-DT40&LC2DT32-DT40_Le Vaudreuil
VERSION
1.0
DATE
20 Oct 2025
REVISION
1.0
CB Certificate _ TeSys Deca_ LC1D188-258&LC1DT32-DT40&LC2DT32-DT40_Batam_ HYDERABAD
VERSION
1.0
DATE
04 Sep 2025
REVISION
1.0
CCC_TeSys Deca_LC1D188-258&LC1DT32-DT40&LC2DT32-DT40_Hyderabad
VERSION
1.0
DATE
18 Jun 2025
REVISION
1.0
DNV Type Approval Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40&CAD&LAD
VERSION
1.0
DATE
16 Aug 2024
REVISION
1.0
EU RO MR Type Approval Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40&CAD&LAD
VERSION
1.0
DATE
16 Aug 2024
REVISION
1.0
EU Declaration TeSys D_LC1D25-38&LC2D25-38&LC1D183&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40
VERSION
1.0
DATE
16 Apr 2025
REVISION
1.0
UKCA Declaration TeSysD_LC1D25-38&LC2D25-38&LC1D183&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40
VERSION
1.0
DATE
16 Apr 2025
REVISION
1.0
LC1DT40ED EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT40ED EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT40ED EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT40ED EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT40ED EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT40ED EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT40ED EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT40ED EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT40ED REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT40ED REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT40ED REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT40ED REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
Related products
DISCONTINUED
LADT9R1V
TeSys D Kit for assembling 4P changeover Contactors
LC1DT20-DT40 with screw clamp terminals, with electrical interlock
Recently viewed
DISCONTINUED
LC1DT40ED
TeSys D Contactor
TeSys Deca, 4P(4 NO), AC-1, 0 to 440V, 40A, 48VDC standard coil
DISCONTINUED
GV2P08
TeSys GV2 Motor circuit breaker
TeSys Deca, 3P, 2.5 to 4A, thermal magnetic, screw clamp terminals, rotary handle
DISCONTINUED
ATV312H055N4
Altivar 312 Variable speed drive ATV312
0.55kW, 1.8kVA, 37W, 380..500 V, 3-phase supply
DISCONTINUED
LADT9R1V
TeSys D Kit for assembling 4P changeover Contactors
LC1DT20-DT40 with screw clamp terminals, with electrical interlock
DISCONTINUED
LC1D1150046E7
TeSys D Contactor
4P (4NO), AC-1 <=440V 200 A, 48 V AC 50/60 Hz coil, lugs/bars terminals
DISCONTINUED
LC1DT25M7
TeSys D Contactor
TeSys Deca, 4P(4 NO), AC-1, 0 to 440V, 25A, 220VAC 50/60Hz coil
DISCONTINUED
NSYS3X8830H
Spacial S3X Wall mounted enclosure
stainless steel 316L, plain door, 800x800x300mm, IP66
DISCONTINUED
GB2CD07
TeSys GB2 Circuit breaker
1P+N, 2A, Icu 15kA at 240V, Thermal magnetic, DIN rail mounted
DISCONTINUED
QO120B10RCBO30F
Square D QO Earth leakage circuit breaker
1P + Ns, B curve, 20A, 30mA
DISCONTINUED
LC1DT40ED
TeSys D Contactor
TeSys Deca, 4P(4 NO), AC-1, 0 to 440V, 40A, 48VDC standard coil
DISCONTINUED
GV2P08
TeSys GV2 Motor circuit breaker
TeSys Deca, 3P, 2.5 to 4A, thermal magnetic, screw clamp terminals, rotary handle
DISCONTINUED
ATV312H055N4
Altivar 312 Variable speed drive ATV312
0.55kW, 1.8kVA, 37W, 380..500 V, 3-phase supply
DISCONTINUED
LADT9R1V
TeSys D Kit for assembling 4P changeover Contactors
LC1DT20-DT40 with screw clamp terminals, with electrical interlock
DISCONTINUED
LC1D1150046E7
TeSys D Contactor
4P (4NO), AC-1 <=440V 200 A, 48 V AC 50/60 Hz coil, lugs/bars terminals
DISCONTINUED
LC1DT25M7
TeSys D Contactor
TeSys Deca, 4P(4 NO), AC-1, 0 to 440V, 25A, 220VAC 50/60Hz coil
DISCONTINUED
NSYS3X8830H
Spacial S3X Wall mounted enclosure
stainless steel 316L, plain door, 800x800x300mm, IP66
DISCONTINUED
GB2CD07
TeSys GB2 Circuit breaker
1P+N, 2A, Icu 15kA at 240V, Thermal magnetic, DIN rail mounted
DISCONTINUED
QO120B10RCBO30F
Square D QO Earth leakage circuit breaker
1P + Ns, B curve, 20A, 30mA