Browse all
Browse all

TeSys D Contactor TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 150A, 240V AC 50/60Hz coil, lugs/bars terminals

TeSys D Contactor TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 150A, 240V AC 50/60Hz coil, lugs/bars terminals

Item Number: LC1D1506U7

Datasheet

Product Dimensions

Width icon

Width120 mm

Height icon

Height158 mm

Depth icon

Depth136 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range TeSys
Range of product TeSys Deca
Product or component type contactor
Warranty 18 months

Physical

[ue] rated operational voltage
  • power circuit: <= 1000 V AC 25...400 Hz
  • power circuit: <= 300 V DC
[ie] rated operational current
  • 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
  • 150 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
  • 150 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Mechanical durability 8 Mcycles
Electrical durability
  • 0.85 Mcycles 150 A AC-3 at Ue <= 440 V
  • 1 Mcycles 200 A AC-1 at Ue <= 440 V
  • 0.85 Mcycles 150 A AC-3e at Ue <= 440 V
Connections - terminals
  • control circuit: lugs-ring terminals - external diameter: 8 mm
  • power circuit: lugs-ring terminals - external diameter: 25 mm
  • power circuit: bars 1 - busbar cross section: 5 x 25 mm
Insulation resistance > 10 MOhm for signalling circuit
Mounting support
  • rail
  • plate
Standards
  • CSA C22.2 No 14
  • EN 60947-4-1
  • IEC 60947-4-1
  • IEC 60335-1:Clause 30.2
  • IEC 60335-2-40:Annex JJ
  • UL 60335-2-40:Annex JJ
  • UL 60947-4-1
  • CSA C22.2 No 60947-4-1
  • JIS C8201-4-1
Product certifications
  • UL
  • CCC
  • CSA
  • CE
  • UKCA
  • Marine
  • EAC
Ip degree of protection IP20 front face conforming to IEC 60529
Climatic withstand conforming to IACS E10 exposure to damp heat
Height 158 mm
Width 120 mm
Depth 136 mm
Net weight 2.5 kg
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP0603001EN
Reach regulation Reference contains Substances of Very High Concern above the threshold
China rohs regulation Product out of China RoHS scope
Eu rohs directive Compliant By Exemption

Others

Life cycle assessment data Yes
Substance regulation data deliverable Yes
Legacy weee scope In
Package 1 bare product quantity 1
Average percentage of recycled plastic content 0 %
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Warranty duration(in months) bmecat 18
At least in Europe
Device short name LC1D
Contactor application
  • motor control
  • resistive load
Utilisation category
  • AC-3
  • AC-4
  • AC-1
  • AC-3e
Poles description 3P
[uc] control circuit voltage 240 V AC 50/60 Hz
Motor power kw
  • 40 kW at 220...230 V AC 50/60 Hz (AC-3)
  • 75 kW at 380...400 V AC 50/60 Hz (AC-3)
  • 80 kW at 415...440 V AC 50/60 Hz (AC-3)
  • 90 kW at 500 V AC 50/60 Hz (AC-3)
  • 100 kW at 660...690 V AC 50/60 Hz (AC-3)
  • 75 kW at 1000 V AC 50/60 Hz (AC-3)
  • 22 kW at 400 V AC 50/60 Hz (AC-4)
  • 40 kW at 220...230 V AC 50/60 Hz (AC-3e)
  • 75 kW at 380...400 V AC 50/60 Hz (AC-3e)
  • 80 kW at 415...440 V AC 50/60 Hz (AC-3e)
  • 90 kW at 500 V AC 50/60 Hz (AC-3e)
  • 100 kW at 660...690 V AC 50/60 Hz (AC-3e)
  • 75 kW at 1000 V AC 50/60 Hz (AC-3e)
Motor power hp
  • 40 hp at 200/208 V AC 50/60 Hz for 3 phases motors
  • 50 hp at 230/240 V AC 50/60 Hz for 3 phases motors
  • 100 hp at 460/480 V AC 50/60 Hz for 3 phases motors
  • 125 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility code LC1D
Pole contact composition 3 NO
Protective cover with
[ith] conventional free air thermal current 200 A (at 60 °C) for power circuit
Irms rated making capacity
  • 140 A AC for signalling circuit conforming to IEC 60947-5-1
  • 250 A DC for signalling circuit conforming to IEC 60947-5-1
  • 1660 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 1400 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current
  • 250 A 40 °C - 10 min for power circuit
  • 580 A 40 °C - 1 min for power circuit
  • 1200 A 40 °C - 10 s for power circuit
  • 1400 A 40 °C - 1 s for power circuit
  • 100 A - 1 s for signalling circuit
  • 120 A - 500 ms for signalling circuit
  • 140 A - 100 ms for signalling circuit
Associated fuse rating
  • 10 A gG for signalling circuit conforming to IEC 60947-5-1
  • 315 A gG at <= 690 V coordination type 1 for power circuit
  • 250 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 0.6 mOhm - Ith 200 A 50 Hz for power circuit
Power dissipation per pole
  • 24 W AC-1
  • 13.5 W AC-3
  • 13.5 W AC-3e
[ui] rated insulation voltage
  • power circuit: 600 V CSA certified
  • power circuit: 600 V UL certified
  • power circuit: 1000 V conforming to IEC 60947-4-1
  • signalling circuit: 690 V conforming to IEC 60947-1
  • signalling circuit: 600 V CSA certified
  • signalling circuit: 600 V UL certified
Overvoltage category III
Pollution degree 3
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
Safety reliability level
  • B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1
  • B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Control circuit type AC at 50/60 Hz
Coil technology built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits
  • 0.3...0.5 Uc (-40-70 °C):drop-out AC 50/60 Hz
  • 0.8...1.15 Uc (-40-55 °C):operational AC 50/60 Hz
  • 1...1.15 Uc (55-70 °C):operational AC 50/60 Hz
Inrush power in va
  • 280...350 VA 60 Hz cos phi 0.9 (at 20 °C)
  • 280...350 VA 50 Hz cos phi 0.9 (at 20 °C)
Hold-in power consumption in va
  • 2...18 VA 60 Hz cos phi 0.9 (at 20 °C)
  • 2...18 VA 50 Hz cos phi 0.9 (at 20 °C)
Heat dissipation 3...4.5 W at 50/60 Hz
Operating time
  • 20...35 ms closing
  • 40...75 ms opening
Maximum operating rate 1200 cyc/h at 60 °C
Tightening torque
  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5
  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5
  • power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8
  • power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8
  • control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver pozidriv No 2 M3.5
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type
  • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
  • type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Non-overlap time
  • 1.5 ms on de-energisation between NC and NO contact
  • 1.5 ms on energisation between NC and NO contact
Contact compatibility M13
Protective treatment TH conforming to IEC 60068-2-30
Permissible ambient air temperature around the device
  • -40...60 °C
  • 60...70 °C with derating
Operating altitude 0...3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness
  • vibrations contactor open (2 Gn, 5...300 Hz)
  • vibrations contactor closed (4 Gn, 5...300 Hz)
  • shocks contactor closed (15 Gn for 11 ms)
  • shocks contactor open (6 Gn for 11 ms)
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 19.500 cm
Package 1 width 17.500 cm
Package 1 length 21.000 cm
Package 1 weight 2.212 kg
Unit type of package 2 P06
Number of units in package 2 16
Package 2 height 75.000 cm
Package 2 width 60.000 cm
Package 2 length 80.000 cm
Package 2 weight 48.756 kg
Green premium status for reporting Green Premium product
Total lifecycle carbon footprint 113 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 22.22881266064238
Carbon footprint of the manufacturing phase [a1 to a3] 22 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.7508929239734572
Carbon footprint of the distribution phase [a4] 0.8 kg CO2 eq.
Carbon footprint of the installation phase [a5] 0.2654427709841767
Carbon footprint of the installation phase [a5] 0.3 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 85.59833633093525
Carbon footprint of the use phase [b2, b3, b4, b6] 86 kg CO2 eq.
Sustainable packaging No
Carbon footprint of the end-of-life phase [c1 to c4] 4.425806016866926
Carbon footprint of the end-of-life phase [c1 to c4] 4 kg CO2 eq.
Pvc free Yes
F-gas free N/A
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 113.26929070340219
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard Yes
Packaging without single use plastic Yes
Scip number a530c666-91dd-4119-8d61-f1c22a361ecb
Pvc free Yes
End of life manual availability ENVEOLI100405EN
Take-back No
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • End of Life Manual

  • Environmental Disclosure

  • Installation Instruction

  • Technical illustration

  • Certificates (MSDS)

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)

  • Product Change Notification

Important: Some software files may need a mySchneider or Club login to download.