TeSys D Contactor TeSys Deca, 3P(3NO), AC-3/AC-3e, <=440V, 115A, 48V DC standard coil, lugs/bars terminals
Item Number: LC1D1156ED
Specifications
Design
Range
Range of product
Product or component type
Warranty
Physical
[ue] rated operational voltage
- power circuit: <= 1000 V AC 25...400 Hz
- power circuit: <= 300 V DC
[ie] rated operational current
- 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
- 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
- 115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Mechanical durability
Electrical durability
- 0.8 Mcycles 200 A AC-1 at Ue <= 440 V
- 0.95 Mcycles 115 A AC-3 at Ue <= 440 V
- 0.95 Mcycles 115 A AC-3e at Ue <= 440 V
Connections - terminals
- control circuit: lugs-ring terminals - external diameter: 8 mm
- power circuit: lugs-ring terminals - external diameter: 25 mm
- power circuit: bars 1 - busbar cross section: 5 x 25 mm
Insulation resistance
Mounting support
- plate
- rail
Standards
- CSA C22.2 No 14
- EN 60947-4-1
- EN 60947-5-1
- IEC 60947-4-1
- IEC 60947-5-1
- UL 508
Product certifications
- CSA
- UL
- RINA
- CCC
- BV
- LROS (Lloyds register of shipping)
- DNV
- GOST
- GL
- UKCA
- CE
Ip degree of protection
Climatic withstand
- conforming to IACS E10 exposure to damp heat
- conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Height
Width
Depth
Net weight
Mercury free
Rohs exemption information
Environmental disclosure
Eu rohs directive
China rohs regulation
Eu rohs directive
China rohs regulation
California proposition 65
Others
Legacy weee scope
Package 1 bare product quantity
Warranty duration(in months) bmecat
Weee label
Device short name
Contactor application
- motor control
- resistive load
Utilisation category
- AC-1
- AC-4
- AC-3
- AC-3e
Poles description
[uc] control circuit voltage
Motor power kw
- 30 kW at 220...230 V AC 50/60 Hz (AC-3)
- 55 kW at 380...400 V AC 50/60 Hz (AC-3)
- 59 kW at 415...440 V AC 50/60 Hz (AC-3)
- 75 kW at 500 V AC 50/60 Hz (AC-3)
- 80 kW at 660...690 V AC 50/60 Hz (AC-3)
- 65 kW at 1000 V AC 50/60 Hz (AC-3)
- 18.5 kW at 400 V AC 50/60 Hz (AC-4)
- 30 kW at 220...230 V AC 50/60 Hz (AC-3e)
- 55 kW at 380...400 V AC 50/60 Hz (AC-3e)
- 59 kW at 415...440 V AC 50/60 Hz (AC-3e)
- 75 kW at 500 V AC 50/60 Hz (AC-3e)
- 80 kW at 660...690 V AC 50/60 Hz (AC-3e)
- 65 kW at 1000 V AC 50/60 Hz (AC-3e)
Motor power hp
- 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors
- 40 hp at 230/240 V AC 50/60 Hz for 3 phases motors
- 75 hp at 460/480 V AC 50/60 Hz for 3 phases motors
- 100 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility code
Pole contact composition
Contact compatibility
Protective cover
[ith] conventional free air thermal current
Irms rated making capacity
- 1260 A at 440 V for power circuit conforming to IEC 60947
- 140 A AC for signalling circuit conforming to IEC 60947-5-1
- 250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity
[icw] rated short-time withstand current
- 250 A 40 °C - 10 min for power circuit
- 550 A 40 °C - 1 min for power circuit
- 950 A 40 °C - 10 s for power circuit
- 1100 A 40 °C - 1 s for power circuit
- 100 A - 1 s for signalling circuit
- 120 A - 500 ms for signalling circuit
- 140 A - 100 ms for signalling circuit
Associated fuse rating
- 250 A gG at <= 690 V coordination type 1 for power circuit
- 200 A gG at <= 690 V coordination type 2 for power circuit
- 10 A gG for signalling circuit
Average impedance
Power dissipation per pole
- 24 W AC-1
- 7.9 W AC-3
- 7.9 W AC-3e
[ui] rated insulation voltage
- power circuit: 600 V CSA certified
- power circuit: 600 V UL certified
- power circuit: 1000 V conforming to IEC 60947-4-1
- signalling circuit: 690 V conforming to IEC 60947-1
- signalling circuit: 600 V CSA certified
- signalling circuit: 600 V UL certified
Overvoltage category
Pollution degree
[uimp] rated impulse withstand voltage
Safety reliability level
- B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1
- B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Control circuit type
Coil technology
Control circuit voltage limits
- 0.75...1.2 Uc (-40-55 °C):operational DC
- 0.15...0.4 Uc (-40-70 °C):drop-out DC
- 1...1.2 Uc (55-70 °C):operational DC
Inrush power in w
Hold-in power consumption in w
Operating time
- 20...35 ms closing
- 40...75 ms opening
Time constant
Tightening torque
- control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5
- control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5
- power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8
- power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8
Auxiliary contact composition
Auxiliary contacts type
- type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
- type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency
Minimum switching voltage
Minimum switching current
Non-overlap time
- 1.5 ms on de-energisation between NC and NO contact
- 1.5 ms on energisation between NC and NO contact
Protective treatment
Permissible ambient air temperature around the device
- -40...60 °C
- 60...70 °C with derating
Operating altitude
Fire resistance
Flame retardance
Mechanical robustness
- vibrations contactor open (2 Gn, 5...300 Hz)
- vibrations contactor closed (4 Gn, 5...300 Hz)
- shocks contactor closed (15 Gn for 11 ms)
- shocks contactor open (6 Gn for 11 ms)
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Sustainable packaging
Pvc free
Pvc free
End of life manual availability
Weee label
Warranty (in months)
Documents & downloads
-
All
-
Technical Data Catalogues
-
Data Bulletin
-
Installation Instruction
-
Certificates (MSDS)
-
Declaration of Conformity
-
Declaration of Conformity (Sustainability)
-
Product Change Notification