TeSys D Contactor 4P(4 NO) , AC-1 , <= 440V, 25A, 32V AC 50/60 Hz coil
Item Number: LC1DT25C7
Specifications
Design
Range
Range of product
Product or component type
Warranty
Physical
[ue] rated operational voltage
- power circuit: <= 690 V AC 25...400 Hz
- power circuit: <= 300 V DC
[ie] rated operational current
Mechanical durability
Electrical durability
Connections - terminals
- control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end
- control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
- control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end
- control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end
- control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end
- control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end
- power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end
- power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end
- power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible with cable end
- power circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end
- power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: solid without cable end
- power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: solid without cable end
Insulation resistance
Mounting support
- plate
- rail
Standards
- CSA C22.2 No 14
- EN 60947-4-1
- EN 60947-5-1
- IEC 60947-4-1
- IEC 60947-5-1
- UL 508
Product certifications
- LROS (Lloyds register of shipping)
- RINA
- DNV
- CSA
- UL
- GL
- CCC
- GOST
- BV
Ip degree of protection
Climatic withstand
- conforming to IACS E10 exposure to damp heat
- conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Height
Width
Depth
Net weight
Reach free of svhc
Eu rohs directive
Toxic heavy metal free
Mercury free
China rohs regulation
Rohs exemption information
Environmental disclosure
Circularity profile
Others
Package 1 bare product quantity
Device short name
Contactor application
Utilisation category
Poles description
[uc] control circuit voltage
Compatibility code
Pole contact composition
Protective cover
[ith] conventional free air thermal current
- 10 A (at 60 °C) for signalling circuit
- 25 A (at 60 °C) for power circuit
Irms rated making capacity
- 140 A AC for signalling circuit conforming to IEC 60947-5-1
- 250 A DC for signalling circuit conforming to IEC 60947-5-1
- 250 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity
[icw] rated short-time withstand current
- 30 A 40 °C - 10 min for power circuit
- 61 A 40 °C - 1 min for power circuit
- 105 A 40 °C - 10 s for power circuit
- 210 A 40 °C - 1 s for power circuit
- 100 A - 1 s for signalling circuit
- 120 A - 500 ms for signalling circuit
- 140 A - 100 ms for signalling circuit
Associated fuse rating
- 10 A gG for signalling circuit conforming to IEC 60947-5-1
- 40 A gG at <= 690 V coordination type 1 for power circuit
- 25 A gG at <= 690 V coordination type 2 for power circuit
Average impedance
Power dissipation per pole
[ui] rated insulation voltage
- power circuit: 600 V CSA certified
- power circuit: 600 V UL certified
- signalling circuit: 690 V conforming to IEC 60947-1
- signalling circuit: 600 V CSA certified
- signalling circuit: 600 V UL certified
- power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage category
Pollution degree
[uimp] rated impulse withstand voltage
Safety reliability level
- B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
- B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Control circuit type
Coil technology
Control circuit voltage limits
- 0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz
- 0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz
- 0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz
- 1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
Inrush power in va
- 70 VA 60 Hz cos phi 0.75 (at 20 °C)
- 70 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in va
- 7.5...7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
- 7 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation
Operating time
- 4...19 ms opening
- 12...22 ms closing
Maximum operating rate
Tightening torque
- control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
- control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
- power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
- power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Auxiliary contact composition
Auxiliary contacts type
- type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
- type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency
Minimum switching voltage
Minimum switching current
Non-overlap time
- 1.5 ms on de-energisation between NC and NO contact
- 1.5 ms on energisation between NC and NO contact
Contact compatibility
Protective treatment
Permissible ambient air temperature around the device
- -40...60 °C
- 60...70 °C with derating
Operating altitude
Fire resistance
Flame retardance
Mechanical robustness
- vibrations contactor open (2 Gn, 5...300 Hz)
- vibrations contactor closed (4 Gn, 5...300 Hz)
- shocks contactor closed (15 Gn for 11 ms)
- shocks contactor open (10 Gn for 11 ms)
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Weee
Pvc free
Pvc free
Documents & downloads
hide show-
All
-
CAD Files and Packs
-
Technical Data Catalogues
-
Installation Instruction
-
Declaration of Conformity
-