TeSys D Contactor 3P(3 NO), AC-3/AC-3e, 0 to 440V, 18A, 48VDC low consumption coil
Item Number: LC1D18EL
Datasheet
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| - | |||
| - | |||
| - |
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| 1 | CAR | 3389110361728 | - |
Specifications
Design
| Range of product | TeSys Deca |
|---|---|
| Product or component type | contactor |
| Warranty | 18 months |
Physical
| [ue] rated operational voltage |
|
|---|---|
| [ie] rated operational current |
|
| Mechanical durability | 30 Mcycles |
| Electrical durability |
|
| Connections - terminals |
|
| Insulation resistance | > 10 MOhm for signalling circuit |
| Mounting support |
|
| Connections - terminals | screw clamp terminals |
| Standards |
|
| Product certifications |
|
| Ip degree of protection | IP20 front face conforming to IEC 60529 |
| Climatic withstand |
|
| Height | 77 mm |
| Width | 45 mm |
| Depth | 95 mm |
| Net weight | 0.49 kg |
| Toxic heavy metal free | Yes |
| Mercury free | Yes |
| Rohs exemption information | Yes |
| Environmental disclosure | ENVPEP110230EN |
| Reach regulation | Reference contains Substances of Very High Concern above the threshold |
| China rohs regulation | Product out of China RoHS scope |
| Eu rohs directive | Compliant By Exemption |
Others
| Life cycle assessment data | Yes |
|---|---|
| Substance regulation data deliverable | Yes |
| Legacy weee scope | In |
| Package 3 bare product quantity | 240 |
| Average percentage of recycled plastic content | 0 % |
| Package 2 bare product quantity | 15 |
| Package 1 bare product quantity | 1 |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| At least in Europe | |
| Warranty duration(in months) bmecat | 18 |
| Device short name | LC1D |
| Contactor application |
|
| Utilisation category |
|
| Poles description | 3P |
| [uc] control circuit voltage | 48 V DC |
| Motor power kw |
|
| Motor power hp |
|
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | with |
| [ith] conventional free air thermal current |
|
| Irms rated making capacity |
|
| Rated breaking capacity | 300 A at 440 V for power circuit conforming to IEC 60947 |
| [icw] rated short-time withstand current |
|
| Associated fuse rating |
|
| Average impedance | 2.5 mOhm - Ith 32 A 50 Hz for power circuit |
| Power dissipation per pole |
|
| [ui] rated insulation voltage |
|
| Overvoltage category | III |
| Pollution degree | 3 |
| [uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level |
|
| Control circuit type | DC low consumption |
| Coil technology | built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits |
|
| Inrush power in w | 2.4...2.4 W (at 20 °C) |
| Hold-in power consumption in w | 2.4...2.4 W at 20 °C |
| Operating time |
|
| Time constant | 40 ms |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Tightening torque |
|
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type |
|
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Non-overlap time |
|
| Contact compatibility | M5 |
| [uc] control circuit voltage | 48 V |
| Maximum motor phase current | 18 A |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Permissible ambient air temperature around the device |
|
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness |
|
| Unit type of package 1 | PCE |
| Number of units in package 1 | 1 |
| Package 1 height | 5.000 cm |
| Package 1 width | 9.200 cm |
| Package 1 length | 11.200 cm |
| Package 1 weight | 521.000 g |
| Unit type of package 2 | S02 |
| Number of units in package 2 | 15 |
| Package 2 height | 15.000 cm |
| Package 2 width | 30.000 cm |
| Package 2 length | 40.000 cm |
| Package 2 weight | 8.128 kg |
| Unit type of package 3 | P06 |
| Number of units in package 3 | 240 |
| Package 3 height | 75.000 cm |
| Package 3 width | 60.000 cm |
| Package 3 length | 80.000 cm |
| Package 3 weight | 140.000 kg |
| Green premium status for reporting | Green Premium product |
| Total lifecycle carbon footprint | 22 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [a1 to a3] | 2.7103153960992956 |
| Carbon footprint of the manufacturing phase [a1 to a3] | 3 kg CO2 eq. |
| Carbon footprint of the distribution phase [a4] | 0.1497941374842545 |
| Carbon footprint of the distribution phase [a4] | 0.1 kg CO2 eq. |
| Carbon footprint of the installation phase [a5] | 0.041480539446657784 |
| Carbon footprint of the installation phase [a5] | 0 kg CO2 eq. |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 17.55891891891892 |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 18 kg CO2 eq. |
| Sustainable packaging | Yes |
| Carbon footprint of the end-of-life phase [c1 to c4] | 1.3125800413083537 |
| Carbon footprint of the end-of-life phase [c1 to c4] | 1 kg CO2 eq. |
| Pvc free | Yes |
| F-gas free | N/A |
| Take-back | No |
| Product contributes to saved and avoided emissions | No |
| Removable battery | N/A |
| Total lifecycle carbon footprint | 21.77308903325748 |
| Average percentage of recycled metal content | 0 % |
| Packaging made with recycled cardboard | Yes |
| Packaging without single use plastic | Yes |
| Scip number | 50ae7612-fd2e-41e4-a369-50d0dea6e592 |
| Pvc free | Yes |
| End of life manual availability | ENVEOLI1102030EN |
| Take-back | No |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty (in months) | 18 |
Documents & downloads
-
All
-
CAD Files and Packs
-
Technical Data Catalogues
-
Environmental Disclosure
-
End of Life Manual
-
Technical illustration
-
Certificates (MSDS)
-
Declaration of Conformity
-
Declaration of Conformity (Sustainability)
TeSys - Catalog 2026 - Innovative and connected solutions for motor starters
VERSION
17.0
DATE
11 May 2026
REVISION
17.0
Discover catalog for Altivar Soft Starter ATS490
VERSION
1.0
DATE
23 May 2025
REVISION
1.0
Discover catalog for Altivar Soft Starter ATS430
VERSION
1.0
DATE
18 Apr 2025
REVISION
1.0
Catalog Safety chain solutions & Safety functions English 07/2020
VERSION
2.1
DATE
08 May 2024
REVISION
2.1
UL_Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40_DPE_DC_Coils
VERSION
1.0
DATE
24 Apr 2026
REVISION
1.0
CB Certificate TeSys Deca _LC1D09-18&LC2D09-18_Le Vaudreuil
VERSION
1.0
DATE
08 Apr 2026
REVISION
1.0
CCC_TeSys Deca_LC1D09-18&LC2D09-18_Le Vaudreuil
VERSION
1.0
DATE
08 Apr 2026
REVISION
1.0
CSA Certificate_TeSys GV2ME&GV2RT&GV2P&GV2MC&GV2MP and GV2P Type E & GV2P combined with LC1D09-38 type F
VERSION
1.0
DATE
02 Feb 2026
REVISION
1.0
CSA Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40_DPE
VERSION
1.0
DATE
06 Nov 2025
REVISION
1.0
CB Certificate TeSys D - LC1D09-18&LC2D09-18_Batam_HYDERABAD_plant
VERSION
1.0
DATE
04 Sep 2025
REVISION
1.0
CCC_TeSys Deca_LC1D09-18&LC2D09-18_Hyderabad
VERSION
1.0
DATE
18 Jun 2025
REVISION
1.0
DNV Type Approval Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40&CAD&LAD
VERSION
1.0
DATE
16 Aug 2024
REVISION
1.0
EU RO MR Type Approval Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40&CAD&LAD
VERSION
1.0
DATE
16 Aug 2024
REVISION
1.0
UL_Certificate_TeSys GV2P Type E & GV2P combined with LC1D09-38 type F
VERSION
1.0
DATE
22 Dec 2022
REVISION
1.0
UKCA Declaration TeSysD_LC1D09-18&LC2D09-18_LC1D09-18&LC2D09-18_LC1D098-128&LC1DT20-25&LC2DT20-2
VERSION
1.0
DATE
23 Jan 2026
REVISION
1.0
EU Declaration TeSys D_LC1D09-18&LC2D09-18_LC1D09-18&LC2D09-18_LC1D098-128&LC1DT20-25&LC2DT20-25
VERSION
1.0
DATE
23 Jan 2026
REVISION
1.0
LC1D18EL EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D18EL EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D18EL EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D18EL EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D18EL EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D18EL EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D18EL EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D18EL EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D18EL REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D18EL REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D18EL REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1D18EL REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
Related products
DISCONTINUED
GV2ME20
TeSys GV2 Motor circuit breaker
TeSys Deca, 3P, 13 to 18A, thermal magnetic, screw clamp terminals, button control
DISCONTINUED
LRD21
TeSys LR.D Thermal overload relay
TeSys Deca, 690VAC, 12 to 18A, 1NO+1NC, class 10A, screw clamp
DISCONTINUED
GV2LE20
TeSys GV2 Motor circuit breaker
TeSys Deca,3P,18A,magnetic,toggle control,screw clamp terminals
DISCONTINUED
GV2ME20
TeSys GV2 Motor circuit breaker
TeSys Deca, 3P, 13 to 18A, thermal magnetic, screw clamp terminals, button control
DISCONTINUED
LRD21
TeSys LR.D Thermal overload relay
TeSys Deca, 690VAC, 12 to 18A, 1NO+1NC, class 10A, screw clamp
DISCONTINUED
GV2LE20
TeSys GV2 Motor circuit breaker
TeSys Deca,3P,18A,magnetic,toggle control,screw clamp terminals
Recently viewed
DISCONTINUED
LC1D18EL
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 18A, 48VDC low consumption coil
DISCONTINUED
LC1D65008M5
TeSys D Contactor
4P(2NO+2NC),AC-1,<=440V 80A,220V AC 50Hz coil
DISCONTINUED
C3253243
Acti9 MSC Chassis 3PH+N
250A, 18mm for iC60 MCB, 32 poles, Dual Feed
DISCONTINUED
NSYPLA1074G
Thalassa Floor standing polyester enclosure
Thalassa PLA, plain door, completely sealed, 1000x750x420mm, IP65, IK10
DISCONTINUED
LC1DT60AUD
TeSys D Contactor
4P(4 NO) , AC-1 , <= 440V, 60 A , 250V DC standard coil
DISCONTINUED
LC1D32ND
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 32A, 60VDC standard coil
DISCONTINUED
LC1D65008E7
TeSys D Contactor
4P(2NO+2NC),AC-1 <=440V 80A,48V AC 50/60Hz coil
DISCONTINUED
LRD08
TeSys LR.D Thermal overload relay
TeSys Deca, 690VAC, 3P, 2.5 to 4A, 1NO+1NC, class 10A, screw clamp
DISCONTINUED
LC1D65008D7
TeSys D Contactor
4P(2NO+2NC),AC-1 <=440V 80A,42V AC 50/60Hz coil
DISCONTINUED
T240HF1R25
Clipsal - Cable Management Tangential Junction Box
25mm I.D, HFT, 1 Way Right Hand Entry
DISCONTINUED
852QCP
QC Series Insulated Electrician Plier
Ideally Suited with Quick Connect Product
DISCONTINUED
4CB316/6
Clipsal - Max 4 Miniature circuit breaker
3P 16 A C curve 6000 A 415 V
DISCONTINUED
GV4LE02S
TeSys GV4 Motor circuit breaker
TeSys GV4, 3P, 2A, Icu 100kA, magnetic, EverLink terminals
DISCONTINUED
XVBC6B5
Harmony XVB Indicator bank
illuminated unit, plastic, orange, 70mm, integral flash discharge tube, 5joule, 24V AC/DC
DISCONTINUED
S8033VH
Modena/Strato Adaptor
Suitable for 30 Series Mech, 3 Gang
DISCONTINUED
LC1D18EL
TeSys D Contactor
3P(3 NO), AC-3/AC-3e, 0 to 440V, 18A, 48VDC low consumption coil
DISCONTINUED
C3253243
Acti9 MSC Chassis 3PH+N
250A, 18mm for iC60 MCB, 32 poles, Dual Feed
DISCONTINUED
NSYPLA1074G
Thalassa Floor standing polyester enclosure
Thalassa PLA, plain door, completely sealed, 1000x750x420mm, IP65, IK10
DISCONTINUED
LC1DT60AUD
TeSys D Contactor
4P(4 NO) , AC-1 , <= 440V, 60 A , 250V DC standard coil
DISCONTINUED
LC1D32ND
TeSys D Contactor
TeSys Deca, 3P(3 NO), AC-3/AC-3e, 0 to 440V, 32A, 60VDC standard coil
DISCONTINUED
LC1D65008E7
TeSys D Contactor
4P(2NO+2NC),AC-1 <=440V 80A,48V AC 50/60Hz coil
DISCONTINUED
LRD08
TeSys LR.D Thermal overload relay
TeSys Deca, 690VAC, 3P, 2.5 to 4A, 1NO+1NC, class 10A, screw clamp
DISCONTINUED
LC1D65008D7
TeSys D Contactor
4P(2NO+2NC),AC-1 <=440V 80A,42V AC 50/60Hz coil
DISCONTINUED
T240HF1R25
Clipsal - Cable Management Tangential Junction Box
25mm I.D, HFT, 1 Way Right Hand Entry
DISCONTINUED
852QCP
QC Series Insulated Electrician Plier
Ideally Suited with Quick Connect Product
DISCONTINUED
4CB316/6
Clipsal - Max 4 Miniature circuit breaker
3P 16 A C curve 6000 A 415 V
DISCONTINUED
GV4LE02S
TeSys GV4 Motor circuit breaker
TeSys GV4, 3P, 2A, Icu 100kA, magnetic, EverLink terminals
DISCONTINUED
XVBC6B5
Harmony XVB Indicator bank
illuminated unit, plastic, orange, 70mm, integral flash discharge tube, 5joule, 24V AC/DC