Modicon M241 Network Switch Module 1 Profibus DP Slave
Item Number: TM4PDPS1
This communication module is proposed as an option Modicon M241/251 controllers. This module provides slave Profibus DP. It is equipped with a 9-way SUB-D connector.
Specifications
Design
Product or component type
Product compatibility
- Modicon M241 logic controller
- Modicon M251 logic controller
Physical
Range compatibility
- Modicon M251
- Modicon M241
Integrated connection type
Communication port protocol
- Profibus DP V0
- Profibus DP V1
Local signalling
- 1 LED (green/yellow) for power supply
- 1 LED (green/red) for communication
Marking
Mounting support
- top hat type TH35-15 rail conforming to IEC 60715
- top hat type TH35-7.5 rail conforming to IEC 60715
- plate or panel with fixing kit
Width
Height
Depth
Net weight
Standards
- IEC 61131-2
- UL 508
- EIA-485
Product certifications
- C-Tick
- cULus
Ambient air temperature for operation
- -10...55 °C horizontal installation
- -10...50 °C vertical installation
Ambient air temperature for storage
Relative humidity
- 10...95 %, without condensation (in operation)
- 10...95 %, without condensation (in storage)
Ip degree of protection
Mercury free
Rohs exemption information
Environmental disclosure
Eu rohs directive
Reach regulation
China rohs regulation
California proposition 65
Others
Legacy weee scope
Weee label
Average percentage of recycled plastic content
Package 2 bare product quantity
Package 1 bare product quantity
Current consumption
Power dissipation in w
Transmission rate
- 1.5 Mbit/s for bus length of 200-200 m
- 500 kbit/s for bus length of 400-400 m
- 187.5 kbit/s for bus length of 1000-1000 m
- 9.6...93.75 kbit/s for bus length of 1200-1200 m
- 3...12 Mbit/s for bus length of 100-100 m
Insulation
Electrical connection
- screw connector terminal for connecting the functional ground
- SUB-D 9 1 female connector for connecting Profibus
Surge withstand
- 1 kV power lines (DC) common mode conforming to IEC 61000-4-5
- 2 kV power lines (AC) common mode conforming to IEC 61000-4-5
- 2 kV relay output common mode conforming to IEC 61000-4-5
- 1 kV I/O common mode conforming to IEC 61000-4-5
- 1 kV shielded cable common mode conforming to IEC 61000-4-5
- 0.5 kV power lines (DC) differential mode conforming to IEC 61000-4-5
- 1 kV power lines (AC) differential mode conforming to IEC 61000-4-5
- 1 kV relay output differential mode conforming to IEC 61000-4-5
- 0.5 kV I/O differential mode conforming to IEC 61000-4-5
Resistance to electrostatic discharge
- 8 kV in air conforming to IEC 61000-4-2
- 4 kV on contact conforming to IEC 61000-4-2
- 8 kV in air conforming to Marine specification (LR, ABS, DNV, GL)
- 6 kV on contact conforming to Marine specification (LR, ABS, DNV, GL)
Resistance to electromagnetic fields
- 10 V/m 80 MHz...1 GHz conforming to IEC 61000-4-3
- 3 V/m 1.4 GHz...2 GHz conforming to IEC 61000-4-3
- 1 V/m 2...2.7 GHz conforming to IEC 61000-4-3
Resistance to fast transients
- 2 kV (power lines) conforming to IEC 61000-4-4
- 2 kV (relay output) conforming to IEC 61000-4-4
- 1.5 kV (I/O) conforming to IEC 61000-4-4
- 1 kV (Ethernet line) conforming to IEC 61000-4-4
- 1 kV (serial link) conforming to IEC 61000-4-4
Resistance to conducted disturbances
- 10 V 0.15...80 MHz conforming to IEC 61000-4-6
- 3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL)
- 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
Electromagnetic emission
- conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15-0.5 MHz conforming to IEC 55011
- conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5-300 MHz conforming to IEC 55011
- conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10-150 kHz conforming to IEC 55011
- conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5-30 MHz conforming to IEC 55011
- radiated emissions - test level: 40 dBμV/m QP class A at 30-230 MHz conforming to IEC 55011
- radiated emissions - test level: 60...54 dBμV/m QP at 30-100 MHz conforming to Marine specification (LR, ABS, DNV, GL)
- radiated emissions - test level: 24 dBμV/m QP at 156-165 MHz conforming to Marine specification (LR, ABS, DNV, GL)
- conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150-1500 kHz conforming to IEC 55011
- radiated emissions - test level: 47 dBμV/m QP class A at 230-1000 MHz conforming to IEC 55011
- radiated emissions - test level: 80...50 dμV/m QP at 150-30000 kHz conforming to Marine specification (LR, ABS, DNV, GL)
- radiated emissions - test level: 54 dBμV/m QP at 100-2000 MHz conforming to Marine specification (LR, ABS, DNV, GL)
Pollution degree
Operating altitude
Storage altitude
Vibration resistance
- 1 mm at 5-13.2 Hz on symmetrical rail
- 3 gn at 8.7-150 Hz on symmetrical rail
- 1 mm at 5-13.2 Hz on panel mounting
- 0.7 gn at 13.2-100 Hz on panel mounting
Shock resistance
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Unit type of package 2
Number of units in package 2
Package 2 height
Package 2 width
Package 2 length
Package 2 weight
Green premium status for reporting
Total lifecycle carbon footprint
Carbon footprint of the manufacturing phase [a1 to a3]
Carbon footprint of the manufacturing phase [a1 to a3]
Carbon footprint of the distribution phase [a4]
Carbon footprint of the distribution phase [a4]
Carbon footprint of the installation phase [a5]
Carbon footprint of the installation phase [a5]
Carbon footprint of the use phase [b2, b3, b4, b6]
Carbon footprint of the use phase [b2, b3, b4, b6]
Sustainable packaging
Carbon footprint of the end-of-life phase [c1 to c4]
Carbon footprint of the end-of-life phase [c1 to c4]
Pvc free
Take-back
Product contributes to saved and avoided emissions
Removable battery
Total lifecycle carbon footprint
Average percentage of recycled metal content
Packaging made with recycled cardboard
Packaging without single use plastic
Scip number
Pvc free
End of life manual availability
Take-back
Weee label
Warranty (in months)
Documents & downloads
hide show-
All
-
CAD Files and Packs
-
Technical Data Catalogues
-
End of Life Manual
-
Environmental Disclosure
-
Installation Instruction
-
Operating Manuals
-
Technical Drawing
-
Certificates (MSDS)
-
Declaration of Conformity
-
Declaration of Conformity (Sustainability)