Browse all
Browse all

Harmony Timer Relays Modular timing relay 0.7A, 1s..100h, off delay, solid state output, 24...240V AC

Home ProductsIndustrialHarmonyModular timing relay

Harmony Timer Relays Modular timing relay 0.7A, 1s..100h, off delay, solid state output, 24...240V AC

Item Number: RE17LCBM

Datasheet

Product Dimensions

Width icon

Width17.5 mm

Height icon

Height90 mm

Depth icon

Depth72 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product Harmony Timer Relays
Product or component type modular timing relay

Physical

Width 17.5 mm
Connections - terminals screw connectors
[in] rated current 0.7 A
Height 90 mm
Depth 72 mm
Control type selector switch front panel
Insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1
Connections - terminals
  • screw terminals, 1 x 0.5...1 x 3.3 mm² (20 AWG...12 AWG) solid without cable end
  • screw terminals, 2 x 0.5...2 x 2.5 mm² (20 AWG...14 AWG) solid without cable end
  • screw terminals, 1 x 0.2...1 x 2.5 mm² (24 AWG...14 AWG) flexible with cable end
  • screw terminals, 2 x 0.2...2 x 1.5 mm² (24 AWG...16 AWG) flexible with cable end
Electrical durability 100000000 cycles
Marking CE
Mounting position any position in relation to normal vertical mounting plane
Mounting support 35 mm DIN rail conforming to IEC 60715
Function available C- Off-delay relay w/ control signal-1 solid state output
Control type without test button
Net weight 0.068 kg
Derating factor 5 mA/°C
Standards
  • 2004/108/EC
  • IEC 61000-6-3
  • 2006/95/EC
  • IEC 61000-6-2
  • IEC 61812-1
  • IEC 61000-6-4
  • IEC 61000-6-1
Product certifications
  • CSA
  • GL
  • cULus
Ambient air temperature for storage -30...60 °C
Ambient air temperature for operation -20...60 °C
Ip degree of protection
  • IP20 (terminal block) conforming to IEC 60529
  • IP40 (housing) conforming to IEC 60529
  • IP50 (front panel) conforming to IEC 60529
Relative humidity 93 % without condensation conforming to IEC 60068...2-30
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP1211017EN
Eu rohs directive Compliant By Exemption
California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Others

Package 1 bare product quantity 1
Average percentage of recycled plastic content 0 %
Legacy weee scope Out
Warranty duration(in months) bmecat 18
Weee label No
At least in Europe
Discrete output type solid state
Component name RE17L
Time delay type off-delay
Time delay range
  • 10...100 h
  • 6...60 s
  • 6...60 min
  • 1...10 h
  • 1...10 s
  • 1...10 min
  • 0.1...1 s
Nominal output current 0.7 A
[uc] control circuit voltage 24...240 V
Contacts type and composition 1 C/O
Output type solid state
[us] rated supply voltage 24...240 V AC 50/60 Hz
Voltage range 0.85...1.1 Us
Supply frequency 50...60 Hz +/- 5 %
Input voltage 7 V
Impulse duration 0.05 s typical
[uimp] rated impulse withstand voltage 5 kV during 1.2/50 µs
Maximum delay response 100 ms
Tightening torque 0.6...1 N.m conforming to IEC 60947...1
Dielectric strength 2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
Housing material polycarbonate
Repeat accuracy +/- 0.5 % conforming to IEC 61812-1
Temperature drift +/- 0.05 %/°C
Voltage drift +/- 0.2 %/V
Setting accuracy of time delay +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Time delay type off-delay - C- Off-delay relay w/ control signal
Reset time 350 ms on de-energisation typical
On-load factor 100 %
Power consumption in va 0...3 VA at 240 V AC
Breaking capacity
  • 0.5 A AC conforming to UL
  • 0.7 A AC at 20 °C
Operating rate in hz 10 Hz
Maximum output current 20 A
Minimum switching current 10 mA
Maximum leakage current 5 mA
Maximum switching voltage 250 V AC
Maximum voltage drop
  • <4 V 3-wire
  • <8 V 2-wire
Creepage distance 4 kV/3 conforming to IEC 60664-1
Safety reliability data
  • MTTFd = 353.8 years
  • B10d = 320000
Time delay type C
Functionality off-delay timing
Number of functions 1
Compatibility code RE17
Immunity to microbreaks 20 ms
Vibration resistance 20 m/s² (f= 10-150 Hz) conforming to IEC 60068-2-6
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Electromagnetic compatibility
  • electrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2
  • electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2
  • susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC 61000-4-3
  • electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to IEC 61000-4-4
  • electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4
  • 1.2/50 µs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5
  • 1.2/50 µs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5
  • conducted RF disturbances: (0.15...80 MHz), level 3, 10 V, conforming to IEC 61000-4-6
  • voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11
  • voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11
  • conducted and radiated emissions: , class B, conforming to EN 55022
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 2.7 cm
Package 1 width 7.8 cm
Package 1 length 9.5 cm
Package 1 weight 71.0 g
Unit type of package 2 S02
Number of units in package 2 40
Package 2 height 15.0 cm
Package 2 width 30.0 cm
Package 2 length 40.0 cm
Package 2 weight 3.348 kg
Green premium status for reporting Green Premium product
Total lifecycle carbon footprint 70 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 1.5748826200254782
Carbon footprint of the manufacturing phase [a1 to a3] 2 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.06073503980883086
Carbon footprint of the distribution phase [a4] 0.1 kg CO2 eq.
Carbon footprint of the installation phase [a5] 0.000578510759075057
Carbon footprint of the installation phase [a5] 0 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 67.93173519403902
Carbon footprint of the use phase [b2, b3, b4, b6] 68 kg CO2 eq.
Sustainable packaging Yes
Carbon footprint of the end-of-life phase [c1 to c4] 0.1814786305252298
Carbon footprint of the end-of-life phase [c1 to c4] 0.2 kg CO2 eq.
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 69.74940999515763
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard Yes
Packaging without single use plastic Yes
Scip number 7bdc2711-0ad2-427c-8ece-532c5e9f09d7
End of life manual availability ENVEOLI121113EN
Take-back No
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Environmental Disclosure

  • End of Life Manual

  • Installation Instruction

  • Technical illustration

  • Certificates (MSDS)

  • eTechPub

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.