MAX9 Residual Current Breaker with Overcurrent Protection (RCBO) 1PN, 40A, 30mA, C Curve, 6000A, A Type, 2 MOD
Item Number: MX9R3240
Datasheet
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| - | |||
| - | |||
| - |
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| 1 | PCE | 9311554813079 | - |
Ultimate Efficiency and Professional Finish
- MAX9 takes the definition of a busbar to next level with MAXBAR. MAXBAR helps to improve installation speed by up to 15 times when compared to using cables for feeding RCBOs
- With MAXBAR, no cable connections are needed to feed final sub-circuits protected by an RCBO or AFDD - it picks up the active feed from main switch and distributes both active & neutral across all type of Clipsal RCBOs and AFDDs
MAX Innovation & Performance
- Innovation is at the core of everything at Clipsal. MAX9 is no exception to that. MAX9 brings in Arc Fault Detection Device (AFDD) to help take the safety of Australian homes to next level
- Enjoy best-in-class performance with 100A rated system. MAX9 products are designed for tough Aussie conditions with operating temperature ranging from -25 Deg C to +70 Deg C with derating
- When it comes to circuit protection, it all comes down to what's on the inside. MAX9 breakers are solidly built and designed to endure 20K mechanical cycles and 10K electrical cycles*
Peace of Mind
- Amendment 2 of "Wiring rules" mandate type A RCDs from 2023. All RCBOs and RCDs in MAX9 range are already type A so that you can be future ready
- MAX9 system comes type tested as per the requirements of AS/NZS 61439-3 to provide you additional peace of mind
- Clipsal MAX9 range comes with 7 year warranty for the ultimate peace of mind
Simplify Safety & Digital Experience
- Sometimes it could be hard to explain circuit protection category to home owners. MAX9 helps to simplify safety by explaining types of circuit protection to home owners with simple pictograms
- MAX9 range takes the digital experience to next level with QR codes on each product to easily access all technical information like specifications, brochures, installation instructions, FAQs and videos
Specifications
Design
| Range | MAX9 |
|---|---|
| Product or component type | residual current breaker with overcurrent protection (RCBO) |
| Warranty | 7-year |
Physical
| [in] rated current | 40 A at 30 °C conforming to AS/NZS 61009.1 |
|---|---|
| [ue] rated operational voltage | 240 V AC 50/60 Hz |
| Height | 91 mm |
| Width | 36 mm |
| Depth | 75 mm |
| Net weight | 268 g |
| Connections - terminals |
|
| Standards |
|
| Ip degree of protection | IP20 |
| Ambient air temperature for operation | -25...70 °C |
| Mercury free | Yes |
| Rohs exemption information | Yes |
| Environmental disclosure | ENVPEP2210010EN |
| Reach regulation | Reference contains Substances of Very High Concern above the threshold |
| China rohs regulation | Product out of China RoHS scope |
| Eu rohs directive | Compliant By Exemption |
Others
| Legacy weee scope | In |
|---|---|
| Package 1 bare product quantity | 1 |
| Package 2 bare product quantity | 6 |
| Average percentage of recycled plastic content | 0 % |
| Outside of Europe | |
| Warranty duration(in months) bmecat | 84 |
| Weee label | N/A |
| Poles description | 1P + N |
| Number of protected poles | 1 |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Curve code | C |
| Earth-leakage sensitivity | 30 mA |
| Earth-leakage protection class | type A |
| Earth-leakage protection time delay | instantaneous |
| Breaking capacity | 6000 A Icn at 240 V AC 50/60 Hz |
| Limitation class | 3 |
| [ui] rated insulation voltage | 440 V AC 50/60 Hz |
| [uimp] rated impulse withstand voltage | 4 kV |
| 9 mm pitches | 4 |
| Comb busbar and distribution block compatibility | YES |
| Temperature derating table |
|
| Grid distance | 45 mm |
| Quality labels | RCM |
| Pollution degree | 2 |
| Overvoltage category | III |
| Unit type of package 1 | PCE |
| Number of units in package 1 | 1 |
| Package 1 height | 8.4 cm |
| Package 1 width | 4.4 cm |
| Package 1 length | 10.2 cm |
| Package 1 weight | 242 g |
| Unit type of package 2 | BB1 |
| Number of units in package 2 | 6 |
| Package 2 height | 8.6 cm |
| Package 2 width | 24.4 cm |
| Package 2 length | 10.3 cm |
| Package 2 weight | 1.452 kg |
| Green premium status for reporting | Green Premium product |
| Total lifecycle carbon footprint | 116 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [a1 to a3] | 3.5662160527 |
| Carbon footprint of the manufacturing phase [a1 to a3] | 4 kg CO2 eq. |
| Carbon footprint of the distribution phase [a4] | 0.031200299 |
| Carbon footprint of the distribution phase [a4] | 0 kg CO2 eq. |
| Carbon footprint of the installation phase [a5] | 0.0004172443 |
| Carbon footprint of the installation phase [a5] | 0 kg CO2 eq. |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 112.249375 |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 112 kg CO2 eq. |
| Sustainable packaging | Yes |
| Carbon footprint of the end-of-life phase [c1 to c4] | 0.0362737284 |
| Carbon footprint of the end-of-life phase [c1 to c4] | 0 kg CO2 eq. |
| Halogen-free status | Halogen free product |
| F-gas free | N/A |
| Take-back | No |
| Product contributes to saved and avoided emissions | No |
| Removable battery | N/A |
| Total lifecycle carbon footprint | 115.8834823244 |
| Average percentage of recycled metal content | 0 % |
| Packaging made with recycled cardboard | Yes |
| Packaging without single use plastic | Yes |
| Halogen-free status | Halogen free product |
| End of life manual availability | N/A |
| Take-back | No |
| Warranty (in months) | 84 |
Documents & downloads
-
All
-
Product Brochures
-
CAD Files and Packs
-
Environmental Disclosure
-
Installation Instruction
-
Certificates (MSDS)
-
Declaration of Conformity (Sustainability)
Fast installation speed with unmatched flexibility
- Up to 15 times faster installation with MAXBAR
- Separate indicator windows for MCB trip or RCD trip for easy diagnosis in case of tripping of device.
- Compatible with multiple types of screw-drivers with combination head screws
- Double locking clip for ease of installation or removal from MAXBAR
Helps to provide additional safety
- Type A RCD to sense a.c. as well as pulsating d.c.
- Option of Type A-SI for high dependency applications
- Switching of both active and neutral contacts
- Positive contact Indicator on toggle that indicates opening of all poles
Peace of mind with complete solution
- Short circuit breaking capacity of 6kA
- Caters for current ratings from 10A to 40A (32A for type A-SI)
- Designed for touch Aussie conditions with operating temperature range of -25 Deg C to +70 Deg C (derating applies)
- Designed to last with endurance performance of 10K electrical cycles and 20K mechanical cycles
- Compatible with A9A26970 padlocking device
Related products
DISCONTINUED
MX9R3210S
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 10A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD
DISCONTINUED
MX9R3210
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 10A, 30mA, C Curve, 6000A, A Type, 2 MOD
DISCONTINUED
MX9R3216S
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 16A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD
DISCONTINUED
MX9R3216
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 16A, 30mA, C Curve, 6000A, A Type, 2 MOD
DISCONTINUED
MX9R3220S
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 20A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD
DISCONTINUED
MX9R3220
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 20A, 30mA, C Curve, 6000A, A Type, 2 MOD
DISCONTINUED
MX9R3225S
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 25A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD
DISCONTINUED
MX9R3225
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 25A, 30mA, C Curve, 6000A, A Type, 2 MOD
DISCONTINUED
MX9R3232S
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 32A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD
DISCONTINUED
MX9R3232
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 32A, 30mA, C Curve, 6000A, A Type, 2 MOD
DISCONTINUED
MX9R3210S
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 10A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD
DISCONTINUED
MX9R3210
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 10A, 30mA, C Curve, 6000A, A Type, 2 MOD
DISCONTINUED
MX9R3216S
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 16A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD
DISCONTINUED
MX9R3216
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 16A, 30mA, C Curve, 6000A, A Type, 2 MOD
DISCONTINUED
MX9R3220S
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 20A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD
DISCONTINUED
MX9R3220
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 20A, 30mA, C Curve, 6000A, A Type, 2 MOD
DISCONTINUED
MX9R3225S
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 25A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD
DISCONTINUED
MX9R3225
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 25A, 30mA, C Curve, 6000A, A Type, 2 MOD
DISCONTINUED
MX9R3232S
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 32A, 30mA, C Curve, 6000A, A-SI Type, 2 MOD
DISCONTINUED
MX9R3232
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 32A, 30mA, C Curve, 6000A, A Type, 2 MOD
Recently viewed
DISCONTINUED
MX9R3240
MAX9 Residual Current Breaker with Overcurrent Protection (RCBO)
1PN, 40A, 30mA, C Curve, 6000A, A Type, 2 MOD