Compact NSX <630 Circuit breaker ComPact NSX160F, 36kA/415VAC, TMD trip unit 125A, 3 poles 3d
Item Number: LV430631
Specifications
Design
Range
Range of product
Product or component type
Device application
Warranty
Physical
[in] rated current
[ue] rated operational voltage
Control type
Mounting mode
Mechanical durability
Electrical durability
- 7500 cycles at 690 V In
- 15000 cycles at 690 V In/2
- 20000 cycles at 440 V In
- 40000 cycles at 440 V In/2
Mounting support
Protection type
- L : for overload protection (thermal)
- I : for short-circuit protection (magnetic)
Width
Height
Depth
Net weight
Standards
Product certifications
- CCC
- EAC
- Marine
Ip degree of protection
Ik degree of protection
Ambient air temperature for operation
Ambient air temperature for storage
Relative humidity
Eu rohs directive
Mercury free
Rohs exemption information
China rohs regulation
Environmental disclosure
Circularity profile
California proposition 65
Others
Important message
Package 1 bare product quantity
Product name
Device short name
Poles description
Protected poles description
Network type
Network frequency
Suitability for isolation
Utilisation category
Breaking capacity
- 10 kA at 600 V AC 50/60 Hz conforming to UL 508
- 85 kA at 240 V AC 50/60 Hz conforming to UL 508
- 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
- 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
- 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
- 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
- 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
- 35 kA at 480 V AC 50/60 Hz conforming to UL 508
- 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code
Trip unit name
Trip unit technology
Trip unit protection functions
[ui] rated insulation voltage
[uimp] rated impulse withstand voltage
[ics] rated service breaking capacity
- 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
- 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
- 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
- 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
- 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
- 8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Upside connection
Downside connection
Connection pitch
Trip unit rating
Long time pick-up adjustment type ir
Long time pick-up adjustment range
Long time delay adjustment type
[tr] long-time delay adjustment range
- 120...400 s at 1.5 x In
- 15 s at 6 x Ir
Short-time pick-up adjustment type isd
[isd] short-time pick-up adjustment range
Short-time delay adjustment type
Earth-leakage protection
Number of slots
Compatibility code
Overvoltage category
Electrical shock protection class
Pollution degree
Operating altitude
- 0...2000 m without derating
- 2000 m...5000 m with derating
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Unit type of package 2
Number of units in package 2
Package 2 height
Package 2 width
Package 2 length
Package 2 weight
Scip number
Green premium status for reporting
Weee
Carbon footprint (kg.eq.co2 per cr, total life cycle)
Global warming ; total life cycle
Documents & downloads
hide show-
All
-
CAD Files and Packs
-
Product Brochures
-
Technical Data Catalogues
-
Installation Instruction
-
Operating Manuals
-
Technical Drawing
Frequently Asked Questions
What is the replacement for the NS160N Breaker with TM125D?
Hide Showhttp://www.schneider-electric.com.au/en/search/LV430631