Design

Range of product iCT
Range Acti9
Product or component type contactor
Device application heating-low inductive load
Product compatibility
  • iACTp
  • iACTs
  • iATEt
  • iACTc
Market segment
  • small commercial
  • residential
Warranty 18 months

Physical

[ie] rated operational current 100 A AC-7A
Control type remote control
[ue] rated operational voltage 400 V AC 50 Hz
Control signal type maintained
Local signalling action indicator
Mounting mode clip-on
Mounting support 35 mm symmetrical DIN rail
Height 85 mm
Width 108 mm
Depth 60 mm
Electrical durability
  • 30000 cycles EN 61095 400 V 16 A AC 50 Hz AC-7A
  • 30000 cycles UTE C 61-481 400 V 6 A AC 50 Hz AC-7A
  • 30000 cycles IEC 61095 400 V AC 50 Hz AC-7A
Connections - terminals
  • control circuit: tunnel type terminals2 cable(s) 1.5-1.5 mm² rigid
  • control circuit: tunnel type terminals1 cable(s) 1.5-2.5 mm² rigid
  • control circuit: tunnel type terminals2 cable(s) 1.5-2.5 mm² flexible
  • power circuit: tunnel type terminals1 cable(s) 6-35 mm² solid or flexible
Standards
  • EN 61095
  • IEC 61095
  • UTE C 61-481
Ip degree of protection
  • IP20 conforming to IEC 60529
  • IP40 (modular enclosure) conforming to IEC 60529
Relative humidity 95 % at 55 °C
Ambient air temperature for operation -5...60 °C
Ambient air temperature for storage -40...70 °C
Toxic heavy metal free Yes
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP1103008EN
Reach regulation Reference contains Substances of Very High Concern above the threshold
China rohs regulation X
Eu rohs directive Compliant

Others

Package 1 bare product quantity 1
Package 2 bare product quantity 2
Package 3 bare product quantity 16
Legacy weee scope In
At least in Europe
Average percentage of recycled plastic content 0 %
Warranty duration(in months) bmecat 18
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Product name Acti9 iCT
Device short name iCT
Poles description 4P
Pole contact composition 4 NO
Network type AC
Utilisation category
  • AC-1 conforming to EN 60947-4-1
  • AC-7A conforming to EN 61095
  • AC-7A conforming to IEC 61095
  • AC-7A conforming to UTE C 61-481
  • AC-1 conforming to IEC 60947-4-1
[uc] control circuit voltage 220...240 V AC 50 Hz
Network frequency 50 Hz
Maximum power AC-7A: 4.2 W at 400 V AC 50 Hz
[ui] rated insulation voltage 500 V AC 50 Hz
[uimp] rated impulse withstand voltage 4 kV
Switching frequency 100 switching operations/day
Hold-in power consumption in va 13 VA
Inrush power in va 106 VA
9 mm pitches 12
Total power losses 27 W
Power losses per pole 9 W
Tightening torque
  • power circuit: 3.5...3.5 N.m
  • control circuit: 0.8...0.8 N.m A1 / A2
Compatibility code iCT
Noise level 30 dB
Heat dissipation 4.2...4.2 W at 50/60 Hz
Pollution degree 2
Tropicalisation 2 conforming to EN 60947-4-1
Operating altitude 2000 m
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 6.800 cm
Package 1 width 8.800 cm
Package 1 length 10.900 cm
Package 1 weight 621.000 g
Unit type of package 2 BB1
Number of units in package 2 2
Package 2 height 8.300 cm
Package 2 width 9.800 cm
Package 2 length 23.200 cm
Package 2 weight 1.304 kg
Unit type of package 3 S03
Number of units in package 3 16
Package 3 height 30.000 cm
Package 3 width 30.000 cm
Package 3 length 40.000 cm
Package 3 weight 10.919 kg
Green premium status for reporting Green Premium product
Total lifecycle carbon footprint 54 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 3.4141737986809226
Carbon footprint of the manufacturing phase [a1 to a3] 3 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.10450729807619732
Carbon footprint of the distribution phase [a4] 0.1 kg CO2 eq.
Carbon footprint of the installation phase [a5] 0.07803315416619769
Carbon footprint of the installation phase [a5] 0.1 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 50.015845776557285
Carbon footprint of the use phase [b2, b3, b4, b6] 50 kg CO2 eq.
Sustainable packaging No
Carbon footprint of the end-of-life phase [c1 to c4] 0.8180806396119752
Carbon footprint of the end-of-life phase [c1 to c4] 0.8 kg CO2 eq.
Pvc free Yes
Halogen-free status Product contains halogen above thresholds
Energy efficiency optimized False
F-gas free N/A
Updatability N/A
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 54.43064066709258
Bvb Accepted
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard No
Packaging without single use plastic No
Scip number 6763a476-30bc-4d05-a4bb-93f8d65c3771
China rohs label 1
Halogen-free status Product contains halogen above thresholds
Pvc free Yes
End of life manual availability N/A
Take-back No
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • CAD Files and Packs

  • Environmental Disclosure

  • Certificates (MSDS)

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.