C-Bus eDLT Wall Plate Saturn, Enhanced Dynamic Labelling Technology, 5 Key Grid

C-Bus eDLT Wall Plate Saturn, Enhanced Dynamic Labelling Technology, 5 Key Grid | Stainless Steel

Item Number: 5085EDLB-SS

Datasheet

Product Dimensions

Width icon

Width77 mm

Height icon

Height123 mm

Embedding depth icon

Embedding depth23.5 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

C-Bus

Product brand

Clipsal

Product or component type

wall plate

Device application

control

Colour

  • cover plate: pure white
  • grid: black

Product compatibility

LAN cable Cat. 5e

Physical

Provided equipment

  • mounting plate
  • flying lead

Control type

5 x push-button dual-action

Local signalling

status: LED (tri-colour) on push-button

Function of module

proximity sensor monitoring wake-up

Communication port protocol

C-Bus - 2 wires

Connector type

  • mini USB port (rear)
  • socket (rear) for C-Bus

Function available

firmware update by USB

Clamping connection capacity

0.2...1.5 mm²

Fixing mode

by screws

Mounting support

wall

Width

77 mm

Height

123 mm

Depth

35 mm

Embedding depth

23.5 mm

Ip degree of protection

IP20

Ambient air temperature for operation

5...45 °C

Product certifications

  • CE
  • RCM

Mercury free

Yes

Rohs exemption information

Yes

Environmental disclosure

ENVPEP120702EN

Eu rohs directive

Pro-active compliance (Product out of EU RoHS legal scope)

Reach regulation

Reference contains Substances of Very High Concern above the threshold

China rohs regulation

X

Material

Material

glass

Others

Legacy weee scope

In

Outside of Europe

Package 1 bare product quantity

1

Average percentage of recycled plastic content

0 %

Weee label

N/A

Weee applicability

Component

Weee exclusion rationale

Component not in scope – non independent function

Product name

C-Bus Saturn

Switch application

  • lighting
  • timer
  • audio
  • blind control
  • fan speed control
  • scene control
  • on/off switching
  • shutter control
  • dimming up/down control
  • page navigation

Local display

backlit LCD display

Display type

colour TFT display

Display size

2.8 inch

Messages display capacity

up to 4 pages

Information displayed

  • load type
  • temperature
  • power
  • date
  • time
  • operating mode

Number of outputs

  • 16 in 4 page option
  • 5 in 1 page option

[us] rated supply voltage

15...36 V: DC

Maximum supply current

32 mA

User language

multi-language

Electrical connection

flying lead

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

8 cm

Package 1 width

11 cm

Package 1 length

15.5 cm

Package 1 weight

306 g

Unit type of package 2

CAR

Number of units in package 2

8

Package 2 height

20.6 cm

Package 2 width

22.5 cm

Package 2 length

33 cm

Package 2 weight

2.903 kg

Unit type of package 3

PAL

Number of units in package 3

240

Package 3 height

103 cm

Package 3 width

66 cm

Package 3 length

67.5 cm

Package 3 weight

97.082 kg

Green premium status for reporting

Green Premium product

Total lifecycle carbon footprint

203 kg CO2 eq.

Carbon footprint of the manufacturing phase [a1 to a3]

3.149006020395626

Carbon footprint of the manufacturing phase [a1 to a3]

3 kg CO2 eq.

Carbon footprint of the distribution phase [a4]

0.09277965352008848

Carbon footprint of the distribution phase [a4]

0.1 kg CO2 eq.

Carbon footprint of the installation phase [a5]

0.016336650694188475

Carbon footprint of the installation phase [a5]

0 kg CO2 eq.

Carbon footprint of the use phase [b2, b3, b4, b6]

155.87

Carbon footprint of the use phase [b2, b3, b4, b6]

156 kg CO2 eq.

Sustainable packaging

No

Carbon footprint of the end-of-life phase [c1 to c4]

0.18855191055412213

Carbon footprint of the end-of-life phase [c1 to c4]

0.2 kg CO2 eq.

Take-back

No

Product contributes to saved and avoided emissions

No

Removable battery

N/A

Total lifecycle carbon footprint

202.62046934512838

Average percentage of recycled metal content

0 %

Packaging made with recycled cardboard

Yes

Packaging without single use plastic

No

End of life manual availability

ENVEOLI1207002EN

Take-back

No

Warranty (in months)

18
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • End of Life Manual

  • Environmental Disclosure

  • Installation Instruction

  • Operating Manuals

  • Specification Guide

  • Application Notes

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)

  • Software - Release

  • Software - Data Library

Important: Some software files may need a mySchneider or Club login to download.

Frequently Asked Questions

How to update C-Bus eDLT Firmware

Hide Show

NOTE: The following procedure assumes that you have installed the latest version of C-Bus Toolkit which will contain the latest eDLT firmware. 

To update a C-Bus eDLT's firmware

1) Connect the working & powered eDLT to a PC/Laptop via a Mini USB cable
2) Open C-Bus Toolkit in the file menu options select Tools and eDLT Firmware Updater
3) Click on the folder/file selector ... in the eDLT Firmware Updater Dialog 
4) Select the latest version of eDLTFirmware located in the C-Bus Toolkits eDLT firmware directory - typically
C:\Clipsal\CBusToolkit\Firmware\eDLTFirmware
5) Click the Start Update button to start the firmware upgrade process
6) Await for the firmware upgrade process to complete, 
 

eDLT.JPG

Note: The eDLT firmware upgrade process requires a stable C-Bus network (if you are experiencing C-Bus communications issues you will likely experience issues upgrading the firmware) in these cases it may be better to have eDLT closer to C-Bus power supplies or if possible use a test bench C-Bus network to upgrade the eDLT firmware.


 

Toolkit showing no serial number and or display but disappears when toolkit scan is done. Unable to edit or program the unit.

Hide Show

If 5085edlt has the latest  firmware 1.6 and toolkit running is an earlier version than Toolkit V1.16.0 then you will have issues with programming them. Things expect are  i.e no serial number showing up on network scan or able to load up and program the unit.. 

advice to download and run C-Bus Toolkit 1.16.0 or later

No serial number

please see link for C-Bus software: https://www.se.com/ww/en/download/

C-Bus Toolkit 1.6.0 https://download.schneider-electric.com/files?p_Archive_Name=C-Bus-Toolkit_V1160.zip&p_enDocType=Software%20-%20Release&p_Doc_Ref=C-Bus-Toolkit_V1160