Specifications
Design
Range
Product or component type
Warranty
Physical
Mounting support
- symmetrical rail
- plate
[ue] rated operational voltage
[ie] rated operational current
Mechanical durability
Electrical durability
- 100000 cycles AC-21
- 30000 cycles DC-1...5
Connections - terminals
- power circuit: screw clamp terminals10-10 mm² - solid
- power circuit: screw clamp terminals6-6 mm² - flexible - with cable end
Height
Width
Depth
Net weight
Standards
Product certifications
- UL
- CSA
- GL
- UKCA
- CCC
Ip degree of protection
Ambient air temperature for operation
Toxic heavy metal free
Mercury free
Rohs exemption information
Environmental disclosure
Eu rohs directive
Reach regulation
Reach regulation
China rohs regulation
Eu rohs directive
China rohs regulation
Others
Life cycle assessment data
Substance regulation data deliverable
Legacy weee scope
Package 1 bare product quantity
Package 2 bare product quantity
Package 3 bare product quantity
Average percentage of recycled plastic content
Warranty duration(in months) bmecat
Weee label
Product name
Device short name
Compatibility code
Performance level
Poles description
Contacts type and composition
Network type
- AC
- DC
Network frequency
Rated operational power in w
- 11 kW at 500 V (AC-23A)
- 15 kW at 690 V (AC-23A)
- 1.5 kW at 230...240 V (AC-3)
- 7.5 kW at 500 V (AC-3)
- 7.5 kW at 690 V (AC-3)
- 5.5 kW at 230...240 V (AC-23A)
- 11 kW at 400...415 V (AC-23A)
- 7.5 kW at 400...415 V (AC-3)
[ith] conventional free air thermal current
[ithe] conventional enclosed thermal current
Making capacity
- 320 A at 400 V AC-21A
- 320 A at 400 V AC-22A
- 320 A at 400 V AC-23A
Breaking capacity
- 250 A at 400 V (AC-21A)
- 250 A at 400 V (AC-22A)
- 250 A at 400 V (AC-23A)
Rated conditional short-circuit current
- 10 kA at 400 V - associated fuse 35 A aM
- 10 kA at 400 V - associated fuse 35 A gG
[icm] rated short-circuit making capacity
Intermittent duty class
Suitability for isolation
[uimp] rated impulse withstand voltage
[icw] rated short-time withstand current
Tightening torque
Protective treatment
Mechanical robustness
- vibrations 10...150 Hz (1 gn) conforming to IEC 60068-2-6
- shocks 11 ms (30 Gn) conforming to IEC 60068-2-27
Fire resistance
Unit type of package 1
Number of units in package 1
Package 1 height
Package 1 width
Package 1 length
Package 1 weight
Unit type of package 2
Number of units in package 2
Package 2 height
Package 2 width
Package 2 length
Package 2 weight
Unit type of package 3
Number of units in package 3
Package 3 height
Package 3 width
Package 3 length
Package 3 weight
Green premium status for reporting
Total lifecycle carbon footprint
Carbon footprint of the manufacturing phase [a1 to a3]
Carbon footprint of the manufacturing phase [a1 to a3]
Carbon footprint of the distribution phase [a4]
Carbon footprint of the distribution phase [a4]
Carbon footprint of the installation phase [a5]
Carbon footprint of the installation phase [a5]
Carbon footprint of the use phase [b2, b3, b4, b6]
Carbon footprint of the use phase [b2, b3, b4, b6]
Sustainable packaging
Carbon footprint of the end-of-life phase [c1 to c4]
Carbon footprint of the end-of-life phase [c1 to c4]
Pvc free
Halogen-free status
F-gas free
Take-back
Product contributes to saved and avoided emissions
Removable battery
Total lifecycle carbon footprint
Average percentage of recycled metal content
Packaging made with recycled cardboard
Packaging without single use plastic
Scip number
China rohs label
Halogen-free status
Pvc free
End of life manual availability
Take-back
Weee label
Warranty (in months)
Documents & downloads
-
All
-
CAD Files and Packs
-
Technical Data Catalogues
-
Environmental Disclosure
-
Installation Instruction
-
Technical illustration
-
Technical Drawing
-
Certificates (MSDS)
-
Declaration of Conformity
-
Declaration of Conformity (Sustainability)
Frequently Asked Questions
Can you run both V1.17 and V1.16.4 Toolkit on the same PC/Laptop?
Hide ShowNo You can’t run both on the same machine as C-Gate2 & C-Gate3 they can’t co-exits on the same machines(PC/Laptop).
This is mentioned in the Toolkit 1.17 release note.
https://www.se.com/au/en/download/document/C-Bus-Toolkit_V1.17.0/
What is the main update of the firmware (V 1.15.0) for SpaceLogic C-Bus Controllers?
Hide ShowThe new firmware version V1.15.0 is available for 5500NAC2, 5500AC2, 5500NAC, 5500SHAC, LSS5500NAC, LSS5500SHAC.
Released date: 18 October 2023
The main update of this new firmware release (V1.15.0) are:
Features/Enhancements
- Added support for error reporting on new C-Bus digital Dimmer
- Resolved the customer issue with Indicators (Bridged Network)
- Fixed the customer issue where the 5500NAC SetLightingLevel() was broken after firmware 1.14.0.
- Fixed the customer issue where it was not possible to edit schedules on the 5000ETP10W when using 5500NAC firmware versions 1.13.0 or 1.14.0.
- Fixed an issue related to the PulseCBusLevel() function, which appeared to send multiple first stage commands.
- Fixed an issue related to the "Execute during ramping" option for an Event-based script, which was not functioning.
- Addressed a cybersecurity issue by blocking HTTPS requests from REST APIs after five consecutive incorrect login attempts.
Links for Exchange and se.com to download the firmware and the related documents:
Download from SE website:
https://www.se.com/au/en/product-range/2216-spacelogic-cbus-home-automation-system/?parent-subcategory-id=88010&filter=business-5-residential-and-small-business#software-and-firmware
Download from SE Ecoxpert:
https://ecoxpert.se.com/en/spacelogic-c-bus/software-and-firmware/software#tab/documents/downloadDocument/40003156
Where to download the C-Bus Toolkit 1.17.0?
Hide ShowRelease Date: 25/10/2023
Version: V1.17.0
Reference: C-Bus_Toolkit_V1.17.0
C-Gate: 3.2.0 (build 1674)
Operating systems: Windows 11 Professional (64-bit), Windows 10 Professional (64-bit), Windows 10 Enterprise (64-bit), Windows 10, Windows 8, Windows 7.
BREAKING CHANGE
This release introduces a new version of C-Gate 3 that is incompatible with older versions of C-Gate (2.1.11 and below) and C-Bus Toolkit (1.16.4 and below).
This release adds basic support for the DIMDD4 (5504D2D) and DIMDD8 (5508D1D) dimmer devices.
Important Notes:
- C-Gate 3 cannot co-exist on the same machine as C-Gate 2.
- C-Bus Toolkit 1.17.0 (and above) cannot be used with C-Gate 2 (or below).
- Once projects have been converted to the new format, they cannot be used by C-Gate 2 or below.
- We strongly recommend creating a separate back up of projects before installing and running this release.
Link to download C-Bus Toolkit 1.17.0
https://www.se.com/au/en/download/document/C-Bus-Toolkit_V1.17.0/
Where to download the SpaceLogic C-Bus Commission V2.0.0?
Hide ShowRelease Date: 26/10/2023
Version: V2.0.0
Reference: C-Bus-Commission_V2.0.0
C-Gate: 3.2.0 (build 1674)
Operating systems: Windows 11 Professional (64-bit), Windows 10 Professional (64-bit), Windows 10 Enterprise (64-bit), Windows 10.
First Release:
The new C-Bus Commission software is built upon and includes a new version of C-Gate (C-Gate 3.2.0). The new version of C-Gate requires that updates are performed to the broader suite of C-Bus software installed on the PC including C-Bus Toolkit, plus other applications such as PICED, HomeGate, etc.
If you have C-Bus Toolkit V1.16.x or earlier currently installed on your PC, you must also install the latest release of C-Bus Toolkit (V1.17.0 or later) accompanying this release of C-Bus Commission. Both C-Bus Toolkit and C-Bus Commission software applications are bundled with C-Gate 3.2.0.
The new C-Bus Commission software offers capabilities to design a C-Bus project and incorporate the new C-Bus DALI-2 Gateway and DALI devices as well as the new C-Bus Digital Dimmer devices.
Important Notes:
This release includes support for the new project file format used by C-Gate 3.2.0. Only projects that have been successfully converted can be opened.
Once projects have been converted to the new format, they cannot be used by C-Gate 2 or below.
We strongly recommend creating a separate back up of projects before installing and running this release.
Link to download the SpaceLogic C-Bus Commission V2.0.0
https://www.se.com/au/en/download/document/C-Bus-Commission_V2.0.0/
What type of firmware file do the SpaceLogic C-Bus Controllers have?
Hide ShowThe SpaceLogic C-Bus Controllers are 5500NAC2, 5500AC2, 5500NAC, 5500SHAC, LSS5500NAC, LSS5500SHAC.
The firmware file type: image file
The firmware version: 1.15.0
The release date: 18 October 2023
The firmware file name: 5500NAC2_Firmware_V1.15.0.img
Links for Exchange and se.com to download the firmware and the related documents:
From SE website:
https://www.se.com/au/en/download/document/5500NAC2_Firmware-V1.15.0/
or
https://www.se.com/au/en/product-range/2216-spacelogic-cbus-home-automation-system/?parent-subcategory-id=88010&filter=business-5-residential-and-small-business#software-and-firmware
From SE Ecoxpert:
https://ecoxpert.se.com/spacelogic-c-bus/software-and-firmware/firmware#tab/documents
How to upgrade firmware for the SpaceLogic C-Bus Controllers?
Hide ShowThe SpaceLogic C-Bus Controllers are 5500NAC2, 5500AC2, 5500NAC, 5500SHAC, LSS5500NAC, LSS5500SHAC.
Links for Exchange and se.com to download the firmware (image file)
5500NAC2_Firmware_V1.15.0.img
From SE website:
https://www.se.com/au/en/download/document/5500NAC2_Firmware-V1.15.0/
or
https://www.se.com/au/en/product-range/2216-spacelogic-cbus-home-automation-system/?parent-subcategory-id=88010&filter=business-5-residential-and-small-business#software-and-firmware
From SE EcoXpert website:
https://ecoxpert.se.com/spacelogic-c-bus/software-and-firmware/firmware#tab/documents
Upgrade firmware
Access to the Configurator page and System page
The path: Configurator → Utility tab → System button → System tab → Upgrade firmware
Click Choose File button and select the firmware file (5500NAC2_Firmware_V1.15.0.img)
Note:
- Do not switch off the Controller during the installation.
- Clean the browser cache after the installation. Use the settings in your browser or the short cuts [Crtl] + [N] or [Crtl] + [F5].
Where to download the C-Bus Toolkit 1.17.2?
Hide ShowRelease Date: 11/01/2024
Version: V1.17.2
Reference: C-Bus_Toolkit_V1.17.2
C-Gate: 3.2.3 (build 1760)
Operating systems: Windows 11 Professional (64-bit), Windows 10 Professional (64-bit), Windows 10 Enterprise (64-bit), Windows 10, Windows 8, Windows 7
Bug fix:
- Fixed an issue in the Edit Network dialog that prevented the network from being opened or scanned when the interface type was changed from Serial to C-Bus Home Controller.
- Support firmware version 1.3.0 of DIMDD4 (5504D2D) and DIMDD8 (5508D1D) C-Bus Digital Dimmer devices.
Link to download C-Bus Toolkit 1.17.2
https://www.se.com/au/en/download/document/C-Bus-Toolkit_V1.17.2/
Where to download the C-Bus Toolkit 1.17.1?
Hide ShowRelease Date: 08/12/2023
Version: V1.17.1
Reference: C-Bus_Toolkit_V1.17.1
C-Gate: 3.2.2 (build 1716)
Operating systems: Windows 11 Professional (64-bit), Windows 10 Professional (64-bit), Windows 10 Enterprise (64-bit), Windows 10, Windows 8, Windows 7.
Bug fix:
- Issue resolved when clicking the ‘+’ button to add a new application in the eDLT unit dialog.
Updates to C-Gate 3.2.2 include:
- Update C-Bus DALI-2 Gateway firmware version default to version 1.7.0.
- Device update to support C-Bus DALI-2 Gateway and DALI Device Primary Control Function.
- Added support for C-Bus Network Devices section firmware update notification.
- Fixed the transfer of new levels to a C-Bus Controller within existing groups.
Link to download C-Bus Toolkit 1.17.1
https://www.se.com/au/en/download/document/C-Bus-Toolkit_V1.17.1/
"WARNING: Cannot read the Hardware ID of the device" Error when connect TSXP572634M via OSLoader
Hide ShowIssue:
"WARNING: Cannot read the Hardware ID of the device" is showed up when connecting to Modicon Premium TSXP572634M via OSLoader. See below picture.
Solution:
This issue happens if using a V13 or higher version OSLoader to connect Modicon Premium TSXP572634M, Version 10, 11 or 12 works fine.
Where to download the C-Bus Toolkit 1.16.4?
Hide ShowWhere to download the C-Bus Toolkit 1.16.4?
Release Date: 08/09/2023Version: V1.16.4
Reference: C-Bus_Toolkit_V1.16.4
C-Gate: 2.11.11
Operating Systems: Windows 10, Windows 7, Windows 8, Windows Vista, Windows x86 / x64
It contains eDLT firmware version: V1.7.0
https://www.se.com/au/en/download/document/C-Bus-Toolkit_V1.16.4/
Where to download the C-Bus Toolkit 1.16.0?
Hide ShowThe C-Bus Toolkit 1.16.0 (C-Gate 2.11.8.) is released on 08/11/2021, it can be downloaded from Schneider Electric website.
https://www.se.com/au/en/download/document/C-Bus-Toolkit_V1160/
for our latest toolkit please visit the link below:
Control Expert V16.2 System Requirements
Hide ShowHow to confirm if the C-Bus Automation 5500AC2/NAC2 is connected to the internet
Hide ShowUnder Configurator > System > Status > Network Utility
Type google.com in to the IP/Hostname field
If successful you will see package transmit and receive
Toolkit showing no serial number and or display but disappears when toolkit scan is done. Unable to edit or program the unit.
Hide ShowIf 5085edlt has the latest firmware 1.6 and toolkit running is an earlier version than Toolkit V1.16.0 then you will have issues with programming them. Things expect are i.e no serial number showing up on network scan or able to load up and program the unit..
advice to download and run C-Bus Toolkit 1.16.0 or later
please see link for C-Bus software: https://www.se.com/ww/en/download/
C-Bus Toolkit 1.6.0 https://download.schneider-electric.com/files?p_Archive_Name=C-Bus-Toolkit_V1160.zip&p_enDocType=Software%20-%20Release&p_Doc_Ref=C-Bus-Toolkit_V1160
How to set up the second machine to control the same project?
Hide ShowHow to set up the second machine to control the same project?
follow the instruction in toolkit help file ''Setting up a new remote projects connection"
Setting up a new remote projects connection
You can connect to C-Bus projects remotely by setting up connectivity between C-Bus Toolkit software and C-Gate server, and C-Bus Toolkit project folders.
Before you start
|
§ |
The C-Bus Toolkit host computer needs to be able to set up an ethernet connection between the C-Gate server and the C-Bus Toolkit host computer |
|
§ |
Access to the C-Gate server to update a configuration file for the purpose of identifying each C-Bus Toolkit host computer. |
Follow the procedures below to successfully connect remotely to C-Gate project folders.
Obtaining permissions on the ethernet
If you are intending to connect to a C-Bus Toolkit projects which reside on host computers on an ethernet, you must ensure that your computer has permission to access the network. In most cases, the building site computers have firewall protection. To get access, you need to contact the system administrators who grant login and password access.
Identifying the C-Bus Toolkit host computer
The C-Gate server must know of the existence of any C-Bus Toolkit software which wants to gain access to C-Bus project folders. To be a trusted user of the C-Gate server, the hostname or IP address of the C-Bus Toolkit host computer must be added to a configuration file on the C-Gate server.
Finding the IP address of C-Bus Toolkit
To find the IP address from a Microsoft Windows operation system, follow the procedure below:
|
1. |
Click the Start menu on your host computer |
|
2. |
Click the Run... option. The Run dialog box appears. |
|
3. |
Type cmd in the Open: field of the Run dialog box. The cmd.exe window opens. |
|
4. |
At the command line prompt, type: ipconfig. The window displays the ethernet local area connection. |
|
5. |
Look for the IP address in the window. An example of an IP address would be: 10.178.143.159. |
To close the Microsoft Windows command line window, type: exit.
Adding the C-Bus Toolkit IP Address to the C-Gate server
To add the C-Bus Toolkit host computer to the access.txt file, follow the procedure below:
|
1. |
For windows operating systems, the configuration file is named: access.txt and is located at the host computer location of: C:\Clipsal\C-Gate 2\config. Use Microsoft Windows search facility to find the access.txt configuration file. |
|
2. |
Double-click on the access.txt file to open a Microsoft Notepad editing session. This opens the access.txt file in Microsoft Notepad as shown in the sample content below (Note that the exact contents of this file may vary): |
##C-Gate Server Access Control File
## This file was written automatically by a command issued to the server
## Created:Tue Oct 05 16:22:26 CST 2004
## File name: C:\clipsal\c-gate\config\access.txt
interface 0:0:0:0:0:0:0:1 Program
interface 127.0.0.1 Program
interface localhost Program
## End of access control file
|
3. |
Below the interface localhost Program line, add the following: |
remote [IP Address of C-Bus Toolkit host computer] Program
|
4. |
Repeat this for each host C-Bus Toolkit host computer, you want to connect to the C-Gate projects folder. |
|
5. |
Save the file by clicking File menu > Save option in Microsoft Notepad. |
Adding the C-Gate server IP address in C-Bus Toolkit
You need to identify the C-Gate server by its IP address in order to set up C-Bus Toolkit so that it can open the C-Bus Toolkit project folders residing with the C-Gate server. To carry this out, follow the procedure below:
|
1. |
Click on Connect to a Remote C-Gate option in the File menu of C-Bus Toolkit. The C-Gate Site dialog box appears. |
|
2. |
In the Site Name field, type a descriptive name for the C-Gate server project folders. The name must be a single word with no spaces and contain alpha-numeric characters. Characters outside of the following sets: a-z, A-Z, 1-9, are not valid. |
|
3. |
In the Host Name field, type the host computer name of the C-Gate server. If you do not know that precise host name, leave the field blank. |
|
4. |
In the IP Address field, add the IP address - numbers only. |
|
5. |
Click the OK button to save the remote IP location. |
C-Bus Toolkit searches for the remote IP location. If the search is successful, the remote C-Gate project folders appear in the C-Bus Toolkit treeview. If the search result is unsuccessful, C-Bus Toolkit sends an error message.
Toolkit 1.19 fail to load 5753L.PEIRL sensor fix
Hide ShowFix is
Issue resolved by either open in classic by right click or change the preference to classic mode
Toolkit > File> Preferences > then tick classic mode
What is the latest firmware version for C-Bus 5500NAC and 550SHAC Automation Controller?
Hide ShowWhat is the latest firmware version for C-Bus 5500NAC and 550SHAC Automation Controller?
Their latest firmware version is 1.18.0 and released on 27/08/2024, here are their download links:
C-Bus Firmware for 5500NAC Automation Controller V1.18.0
https://www.se.com/au/en/download/document/5500NAC_Firmware-V1.18.0/
C-Bus Firmware for 5500SHAC Automation Controller V1.18.0
https://www.se.com/au/en/download/document/5500SHAC_Firmware-V1.18.0/
or
Where to download the C-Bus PICED 4.14.2?
Hide ShowDate: 29/06/2023
Version: V4.14.2
Reference: PICED-V4.14.2
Operating Systems: Windows 10, Windows 7, Windows 8, Windows Vista, Windows x86 / x64
It contains C-Bus Wiser 2 firmware V1.33.1 and C-Bus Home Controller firmware V2.01.1
https://www.se.com/za/en/download/document/PICED-V4.14.2/
How to install PUSH Module for Somfy RTS v1.3
Hide ShowPlease see the attached PDF user guide
Also attached is the PEMOD Module file that will be required for the installation via PUSH Project Editor.
Where to download the C-Bus Toolkit 1.16.3?
Hide ShowRelease Date: 29/06/2023
Version: V1.16.3
Reference: C-Bus_Toolkit_V1.16.3
C-Gate: 2.11.10
Operating Systems: Windows 10, Windows 7, Windows 8, Windows Vista, Windows x86 / x64
It contains eDLT firmware version: V1.7.0
https://www.se.com/au/en/download/document/C-Bus_Toolkit_V1.16.3/
Control Expert DTM Backward Compatibility
Hide ShowIssue:
Control Expert DTM backward Compatibility .
Product Line:
Control Expert 14.x to higher
Unity Pro 13.x to lower.
Resolution:
DTMs may not be backward compatible. If an application created with Unity Pro/EcoStruxure Control Expert contains DTM version n, do not open and run DTM of version n-1 (or earlier).
DTMs are generally forward compatible. If an application created with Unity Pro/EcoStruxure Control Expert contains DTMs version n, it can be opened and run with DTM version n+1 and above.
As some modules and controller families comes with a DTM (M580 controller, 140CRP312, 140NOC77•, TSXETC101, BMXNOC, BMENOC, 140NOC, HART, PME SW...) this means for example:
-
An M580 application created with Unity Pro V8.1 cannot be built with Unity Pro V8.0.
-
An M340 application with BMXNOC created with Unity Pro V8.1 cannot be built with Unity Pro V8.0.
New BMXNOR0200H Web Page Access is Disabled
Hide ShowIssue:
How to Enable BMXNOR0200H Web Access
Product Line:
BMXNOR0200H
Control Expert
Resolution:
By default the Web Access in BMXNOR0200H is disabled due to Cyber Security Requirement and you have to use Control Expert 14. x onwards to Enable the Web Access please follow the below steps ,
Step1: Try to Configure a Dummy application using Control Expert & Enable the Web Access in Security settings and save the application as .STA
Step2: Please Open the .STA file without doing a build & download it to the CPU after which the CPU should have the Web Access
NOTE:
If you want to disable the Web Access then as mentioned in the image these Services can be disabled only on BMXNOR0200H Firmware version V1.7 or higher
What are the System requirements for Unity Pro V13?
Hide ShowSystem: Pentium Processor 2.4 GHz or higher, recommended 3.0 GHz
RAM memory: 2GB minimum; recommended: 4GB
Hard disk: minimum available free space 8 GB, recommended 20 GB
Microsoft Internet Explorer 5.5 or higher
On Windows 7 64bits System, installation of Windows 7 Service Pack 1 (SP1) is mandatory in order to use Unity Pro V13
Windows 7 64bits is recommended for projects using DTMs (example : projects using Modicon M580 controller)
System with Microsoft Windows 10 32/64bits
System: Pentium Processor 2.4 GHz or higher, recommended 3.0 GHz
RAM memory: 2GB minimum; recommended: 4GB
Hard disk: minimum available free space 8 GB, recommended 20 GB
Windows 10 64bits is recommended for projects using DTMs (example : projects using Modicon M580 controller)
System with Microsoft Windows Server 2012 R2
Recommended version: Windows Server 2012 R2, standard version
Processor recommended: 3.20GHz
RAM memory recommended: 16.0 GB
Important notice
Unity Pro requires .NET 3.5 and .NET 4.5.2
Depending on the target Windows version and Windows configuration, .Net versions may be
- not installed
- installed but not enabled ( the related "windows feature" is not set ON )
- installed and enabled
Unity Pro setup tries to automatically install and enable the required .Net on the target Windows if necessary.
On Windows 10 and Windows Server 2012 R2, automatic or manual installation of .Net 3.5 requires an internet connection.
And service “Windows Update” must be started in order to install the .NET Framework 3.5.
If automatic installation of .Net 3.5 fails, please read & follow Microsoft technical notes on .NET 3.5 installation:
- Installing the .NET Framework 3.5 on Windows 8 or 8.1
https://msdn.microsoft.com/en-us/library/hh506443.aspx
Virtualization:
Unity Pro V13 has been successfully tested in the following configuration :
- VirtualBox 5.0.20
- VMware Workstation 12 Pro 12.1.0 build-3272444
DVD-ROM drive: to install the software;
DVD-ROM writer recommended
Display:
Min VGA (800-600).
Recommended:
· SVGA (1024-768 or more) with high color 24 bits
· SVGA (1280-1024 or more) for Windows 10 and Windows Server 2012 R2
Pointing device:
Mouse or compatible devices.
Access rights on the computer
Unity Pro V13 needs to have Administrator access right for installing the software.
For Unity Pro usage User access right are sufficient
Nevertheless Administrator rights must be used for updating the Hardware catalog (CANopen, DTM)
PRM DTM requires administrator rights to work correctly.
Note:
- User must check that all directories used by Unity pro are accessible in read write mode.
Check for the Options Management: Options / General / Paths:
- Project Path
- Import / Export file path
- XVM path
- Project settings templates path
- Project settings template file
- Custom Library path
- Working drive
- Log file path
Check the directory c:\UnityProTemp (Hidden directory) has the following rights: Read, Execute and Write.
If these paths are not accessible an error message will appear and the requested operation will fail
- Access rights & Multi instances : As some components are shared, when several instances of Unity Pro are launched, rights access must be the same on all the instances
- In Windows 7 , if UAC (User Account Control) is set, and if Unity Pro is executed without checking "Run as Administrator", system folders can be only be accessed in read only and FFB Libset can not be modified.
- Start Menu: following short cuts must be executed with “Run as Administrator”:
- Remove Unity Pro
- Repair Unity Pro
- Types Library Update
Unity Pro V13 Readme file is attached.
C-Bus Cable for underground
Hide ShowTypically for C-Bus underground cable use it needs to be a Cat5E UTP cable with the similar characteristics / impedance as the C-Bus 5005C305B cable.
If you use an underground CAT5E data cable from brands such as belden or garland etc
We would recommend you ask the supplier to provide confirmation they can provide a CAT5E UTP underground equivalent cable Gel filled.
Do not use shielded cabling.
How do I test PLC client and PLC server communication with explicit messaging using Control Expert’s simulator instead of actual hardware?
Hide ShowStep 1: Create an XML file with the format below. Any IP address can be used and assigned to a port.
eg).
<EquiList>
<PLCAdressSim Address="192.168.250.1" Port="502"></PLCAdressSim>
<PLCAdressSim Address="192.168.100.1" Port="503"></PLCAdressSim>
</EquiList>
Step2: Open Control Expert and create a new M580 project. Create a program with the Read_Var block and assign an IP address that corresponds to one of the ports (created in the XML). Eg)
Build and connect to the simulator using the port number not assigned to the IP address used in the ADDM block. Transfer the program and run. Eg)
Step 3: Open another instance of Control Expert and create another blank M580 project. Connect to the simulator as below. The IP address must be 127.0.0.1 but the port number must be the one assigned to the IP address used in the ADDM block previously.
Step 4: From the task bar, select Options from the Simulator menu
Step 5: Enter the location of the .xml file
It will now be possible to monitor the memory read in by the Read_Var block.
Where to download the C-Bus Toolkit 1.16.2 and PICED 4.14.1?
Hide ShowWhere to download the C-Bus Toolkit 1.16.2 and PICED 4.14.1?
C-Bus Toolkit Software and Release Notes - V1.16.2, released on 07/06/2022
https://www.se.com/ww/en/download/document/C-Bus_Toolkit_V1.16.2/
PICED_V4.14.1 Programming Interface for C-Bus Embedded Devices, released on 05/09/2022
https://www.se.com/sg/en/download/document/PICED_V4.14.1/
Note: PICED_V4.14.1 comes with the new C-Bus Wiser 2 firmware 1.32.35 and Home Controller firmware 2.00.24.
Where to download the C-Bus Toolkit 1.17.4?
Hide ShowRelease Date: 02/04/2024
Version: V1.17.4
Reference: C-Bus_Toolkit_V1.17.4
C-Gate: 3.3.0 (build 1825)
Operating systems: Windows 11 Professional (64-bit), Windows 10 Professional (64-bit), Windows 10 Enterprise (64-bit), Windows 10, Windows 8, Windows 7
What’s New
C-Bus DALI-2 Gateway
Additional Measurement and Error Reporting application parameters are now supported in this release (future client feature).
C-Bus Digital Dimmers
The network burden property of the digital dimmer devices are now supported in the network calculator in this release.
Performance Improvement
Support has been added for the extended range of C-Bus replies for both new input and output devices in this release.
Fixes
• Fixed an issue with scanning and opening the older DALI Gateway (5502DAL) devices.
• Fixed an issue with setting the C-Bus power supply property for new output devices (future client feature).
Link to download C-Bus Toolkit 1.17.4
https://www.se.com/au/en/download/document/C-Bus-Toolkit_V1.17.4/
or
https://www.se.com/au/en/product-range/2216-spacelogic-cbus-home-automation-system/?parent-subcategory-id=88010&filter=business-5-residential-and-small-business#software-and-firmware
What is the Part Number for the Mechanical Interlock for the 4-pole LC1DT20, LC1DT25, LC1DT32, and LC1DT40 Contactors?
Hide ShowFour-pole IEC contactors needs the part number for the mechanical interlock
Product Line:
IEC Contactors
Environment:
Tesys D contactors
Resolution:
LADT9R1 is the mechanical interlock and power wiring only. The LADT9RV1 also includes an electrical interlock (2 NC contacts).
How is an Altivar VFD set to always run a particular speed when no reference input is connected?
Hide ShowWants the Altivar VFD set to always run at a particular speed when no reference input is connected.
Product Line:
Altivar 12, 32, 312, 61, 71, 212, 320
Environment:
All models
Cause:
VFD does not run the motor without a speed reference.
Resolution:
If there is no external speed reference when the VFD gets a run command, then it will always run at the minimum speed programmed to the VFD. Set the minimum speed parameter to the desired run speed. Use parameter LSP for the Altivar12, 32, 312, 320, 61, 71 drives. Use parameter LL for the Altivar 212 drive. These can be adjusted while the motor is running.