TeSys D Kit for assembling 3P reversing Contactors LC1D09-D38 with screw clamp terminals, without electrical interlock

Home ProductsIndustrialTeSysKit for assembling 3P reversing Contactors

TeSys D Kit for assembling 3P reversing Contactors LC1D09-D38 with screw clamp terminals, without electrical interlock

Item Number: LAD9R1

TeSys Deca kit for reversing contactors assembly, for 3-pole contactors LC1D09-D38. For assembling 2 identical contactors horizontally mounted, connection by screw clamp terminals. It contains a mechanical interlock LAD9V2 (without electrical interlocking), a set of 3 parallel bars LAD9V5, a set of 3 reverser bars LAD9V6. It conforms to RoHS/REACh regulation.

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys Deca

Range

  • TeSys
  • Linergy

Product or component type

kits for reversing contactor

Product compatibility

  • LC1D09
  • LC1D12
  • LC1D18
  • LC1D25
  • LC1D32
  • LC1D38

Warranty

18 months

Physical

Range compatibility

  • TeSys TeSys D contactor
  • TeSys TeSys Deca

Net weight

0.045 kg

Reach regulation

Free of Substances of Very High Concern above the threshold

Reach free of svhc

Yes

Eu rohs directive

Compliant

Toxic heavy metal free

Yes

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

 Pro-active China RoHS declaration (out of China RoHS legal scope)

Others

Package 1 bare product quantity

1

Package 2 bare product quantity

10

Package 3 bare product quantity

140

Package 4 bare product quantity

1120

Device short name

LAD9

Poles description

3P

Kit composition

  • mechanical interlock
  • set of power connection

Compatibility code

LAD9

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

1.500 cm

Package 1 width

5.500 cm

Package 1 length

11.000 cm

Package 1 weight

61.000 g

Unit type of package 2

BB1

Number of units in package 2

10

Package 2 height

9.400 cm

Package 2 width

10.000 cm

Package 2 length

15.000 cm

Package 2 weight

651.000 g

Unit type of package 3

S03

Number of units in package 3

140

Package 3 height

30.000 cm

Package 3 width

30.000 cm

Package 3 length

40.000 cm

Package 3 weight

9.469 kg

Packaging made with recycled cardboard

Yes

Packaging without single use plastic

No

Weee

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

F-gas usage performance

N/A

Take-back

No

Take-back

No

Product contributes to saved and avoided emissions

No

Removable battery

N/A

Minimum percentage of recycled plastic content

0
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Installation Instruction

  • Declaration of Conformity

  • Certificates (MSDS)

Frequently Asked Questions

What mechanical and electrical interlock kits are available to field assemble a reversing contactor from the LC1D09 through LC1D38 (9 to 38 amp ) Tesys contactors?

Hide Show
Issue:
Identifying interlocks to field assemble a reversing contactor

Product Line:
IEC contactors and starters

Environment:
Products sold and used in the United States

Cause:
Field assembling a reversing IEC contactor

Resolution:
Use the LAD9R1V kit for mechanical and electrical interlocking or use the LAD9R1 kit for mechanical interlocking without electrical interlocking. Both include power connections