TeSys D Contactor TeSys Deca, 4P(4 NO), AC-1, 0 to 440V, 25A, 110VDC standard coil
Item Number: LC1DT25FD
Datasheet
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| - | |||
| - | |||
| - |
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| 1 | PCE | 3389110247817 | - |
Specifications
Design
| Range |
|
|---|---|
| Range of product | TeSys Deca |
| Product or component type | contactor |
| Warranty | 18 months |
Physical
| [ue] rated operational voltage |
|
|---|---|
| [ie] rated operational current | 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
| Mechanical durability | 30 Mcycles |
| Electrical durability | 0.8 Mcycles 25 A AC-1 at Ue <= 440 V |
| Connections - terminals |
|
| Insulation resistance | > 10 MOhm for signalling circuit |
| Mounting support |
|
| Connections - terminals | screw clamp terminals |
| Standards |
|
| Product certifications |
|
| Ip degree of protection | IP20 front face conforming to IEC 60529 |
| Climatic withstand |
|
| Height | 85 mm |
| Width | 45 mm |
| Depth | 99 mm |
| Net weight | 0.365 kg |
| Mercury free | Yes |
| Rohs exemption information | Yes |
| Environmental disclosure | ENVPEP110230EN |
| Reach regulation | Reference contains Substances of Very High Concern above the threshold |
| China rohs regulation | Product out of China RoHS scope |
| Eu rohs directive | Compliant By Exemption |
Others
| Life cycle assessment data | Yes |
|---|---|
| Substance regulation data deliverable | Yes |
| Package 1 bare product quantity | 1 |
| Legacy weee scope | In |
| At least in Europe | |
| Package 2 bare product quantity | 16 |
| Warranty duration(in months) bmecat | 18 |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Package 3 bare product quantity | 256 |
| Average percentage of recycled plastic content | 0 % |
| Device short name | LC1D |
| Contactor application | resistive load |
| Utilisation category | AC-1 |
| Poles description | 4P |
| [uc] control circuit voltage | 110 V DC |
| Compatibility code | LC1D |
| Pole contact composition | 4 NO |
| Protective cover | with |
| [ith] conventional free air thermal current |
|
| Irms rated making capacity |
|
| Rated breaking capacity | 250 A at 440 V for power circuit conforming to IEC 60947 |
| [icw] rated short-time withstand current |
|
| Associated fuse rating |
|
| Average impedance | 2.5 mOhm - Ith 25 A 50 Hz for power circuit |
| Power dissipation per pole | 1.56 W AC-1 |
| [ui] rated insulation voltage |
|
| Overvoltage category | III |
| Pollution degree | 3 |
| [uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level |
|
| Control circuit type | DC standard |
| Coil technology | built-in bidirectional peak limiting diode suppressor |
| Control circuit voltage limits |
|
| Inrush power in w | 5.4...5.4 W (at 20 °C) |
| Hold-in power consumption in w | 5.4...5.4 W at 20 °C |
| Operating time |
|
| Time constant | 28 ms |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Tightening torque |
|
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type |
|
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Non-overlap time |
|
| Contact compatibility | M7 |
| [uc] control circuit voltage | 110 V |
| Rated thermal current (ith) | 25 A |
| Protective treatment | TH conforming to IEC 60068-2-30 |
| Permissible ambient air temperature around the device |
|
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness |
|
| Unit type of package 1 | PCE |
| Number of units in package 1 | 1 |
| Package 1 height | 5.000 cm |
| Package 1 width | 9.000 cm |
| Package 1 length | 11.200 cm |
| Package 1 weight | 557.000 g |
| Unit type of package 2 | S02 |
| Number of units in package 2 | 16 |
| Package 2 height | 15.000 cm |
| Package 2 width | 30.000 cm |
| Package 2 length | 40.000 cm |
| Package 2 weight | 9.172 kg |
| Unit type of package 3 | P06 |
| Number of units in package 3 | 256 |
| Package 3 height | 75.000 cm |
| Package 3 width | 80.000 cm |
| Package 3 length | 60.000 cm |
| Package 3 weight | 154.752 kg |
| Green premium status for reporting | Green Premium product |
| Total lifecycle carbon footprint | 45 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [a1 to a3] | 2.842031658339635 |
| Carbon footprint of the manufacturing phase [a1 to a3] | 3 kg CO2 eq. |
| Carbon footprint of the distribution phase [a4] | 0.15707385257694723 |
| Carbon footprint of the distribution phase [a4] | 0.2 kg CO2 eq. |
| Carbon footprint of the installation phase [a5] | 0.043496416130046754 |
| Carbon footprint of the installation phase [a5] | 0 kg CO2 eq. |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 40.7366918918919 |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 41 kg CO2 eq. |
| Sustainable packaging | Yes |
| Carbon footprint of the end-of-life phase [c1 to c4] | 1.3763689778953017 |
| Carbon footprint of the end-of-life phase [c1 to c4] | 1 kg CO2 eq. |
| Pvc free | Yes |
| F-gas free | N/A |
| Take-back | No |
| Product contributes to saved and avoided emissions | No |
| Removable battery | N/A |
| Total lifecycle carbon footprint | 45.15566279683383 |
| Average percentage of recycled metal content | 0 % |
| Packaging made with recycled cardboard | Yes |
| Packaging without single use plastic | Yes |
| Scip number | 50ae7612-fd2e-41e4-a369-50d0dea6e592 |
| Pvc free | Yes |
| End of life manual availability | ENVEOLI1102030EN |
| Take-back | No |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty (in months) | 18 |
Documents & downloads
-
All
-
CAD Files and Packs
-
Technical Data Catalogues
-
Environmental Disclosure
-
End of Life Manual
-
Installation Instruction
-
Technical illustration
-
Certificates (MSDS)
-
Declaration of Conformity
-
Declaration of Conformity (Sustainability)
UL_Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40_DPE_DC_Coils
VERSION
1.0
DATE
24 Apr 2026
REVISION
1.0
CB_Certificate_TeSys D_LC1D098-128&LC1DT20-25&LC2DT20-25_Le Vaudreuil
VERSION
1.0
DATE
02 Feb 2026
REVISION
1.0
CSA Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40_DPE
VERSION
1.0
DATE
06 Nov 2025
REVISION
1.0
LC1D098-128&LC1DT20-25&LC2DT20-25_Le Vaudreuil
VERSION
1.0
DATE
20 Oct 2025
REVISION
1.0
CB_Certificate_TeSys D_LC1D098-128&LC1DT20-25&LC2DT20-25_Batam
VERSION
1.0
DATE
04 Sep 2025
REVISION
1.0
CCC_TeSys Deca_LC1D098-128&LC1DT20-25&LC2DT20-25_Hyderabad
VERSION
1.0
DATE
18 Jun 2025
REVISION
1.0
CCC_TeSys Deca_LC1D098-128&LC1DT20-25&LC2DT20-25_Batam
VERSION
1.0
DATE
16 Dec 2024
REVISION
1.0
DNV Type Approval Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40&CAD&LAD
VERSION
1.0
DATE
16 Aug 2024
REVISION
1.0
EU RO MR Type Approval Certificate_TeSys D_LC1D09-38&LC2D09-38&LC1D098-128&LC1DT20-25&LC2DT20-25&LC1D188-258&LC1DT32-DT40&LC2DT32-DT40&CAD&LAD
VERSION
1.0
DATE
16 Aug 2024
REVISION
1.0
UKCA Declaration TeSysD_LC1D09-18&LC2D09-18_LC1D09-18&LC2D09-18_LC1D098-128&LC1DT20-25&LC2DT20-2
VERSION
1.0
DATE
23 Jan 2026
REVISION
1.0
EU Declaration TeSys D_LC1D09-18&LC2D09-18_LC1D09-18&LC2D09-18_LC1D098-128&LC1DT20-25&LC2DT20-25
VERSION
1.0
DATE
23 Jan 2026
REVISION
1.0
LC1DT25FD EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT25FD EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT25FD EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT25FD EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT25FD EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT25FD EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT25FD REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT25FD REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT25FD REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT25FD REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT25FD REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
LC1DT25FD REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
Related products
DISCONTINUED
LADT9R1V
TeSys D Kit for assembling 4P changeover Contactors
LC1DT20-DT40 with screw clamp terminals, with electrical interlock
Recently viewed
DISCONTINUED
LC1DT25FD
TeSys D Contactor
TeSys Deca, 4P(4 NO), AC-1, 0 to 440V, 25A, 110VDC standard coil
DISCONTINUED
LXD3K7
TeSys D Contactor Coil
LXD3, 100 V AC 50/60 Hz for 40… 65 A Contactor
DISCONTINUED
LXD1B7
TeSys D Contactor Coil
LXD1, 24V AC 50/60 Hz for 9… 38 A Contactor
DISCONTINUED
CAD32C7
TeSys K Control Relay
3NO+2NC, 0 to 690V, 32VAC 50/60Hz standard coil, screw clamp
DISCONTINUED
ATV32H075M2
Altivar 32 Variable speed drive ATV32
0,75 kw, 200 V, 1 phase, with heat sink
DISCONTINUED
21096
Acti9 1 set of 12 comb busbar tooth covers for Duoline
Clario, Librio, Prodis
DISCONTINUED
INS62042
OptiLine Floorbox with Aluminium
Stainless Steel Finish, Recessed LID
DISCONTINUED
LC1DT25FD
TeSys D Contactor
TeSys Deca, 4P(4 NO), AC-1, 0 to 440V, 25A, 110VDC standard coil
DISCONTINUED
LXD3K7
TeSys D Contactor Coil
LXD3, 100 V AC 50/60 Hz for 40… 65 A Contactor
DISCONTINUED
CAD32C7
TeSys K Control Relay
3NO+2NC, 0 to 690V, 32VAC 50/60Hz standard coil, screw clamp
DISCONTINUED
ATV32H075M2
Altivar 32 Variable speed drive ATV32
0,75 kw, 200 V, 1 phase, with heat sink
DISCONTINUED
21096
Acti9 1 set of 12 comb busbar tooth covers for Duoline
Clario, Librio, Prodis
DISCONTINUED
INS62042
OptiLine Floorbox with Aluminium