Modicon M221 Analogue input cartridge 2 temperature inputs, I/O extension

Home ProductsIndustrialModiconAnalogue input cartridge

Modicon M221 Analogue input cartridge 2 temperature inputs, I/O extension

Item Number: TMC2TI2

Datasheet

Product Dimensions

Width icon

Width35 mm

Height icon

Height41 mm

Depth icon

Depth15 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

Modicon M221

Product or component type

analogue input cartridge

Product compatibility

Modicon M221C

Physical

Type of cable

twisted shielded pairs cable

Height

41 mm

Depth

15 mm

Width

35 mm

Net weight

0.015 kg

Toxic heavy metal free

Yes

Mercury free

Yes

Rohs exemption information

Yes

Environmental disclosure

ENVPEP1403017EN

Eu rohs directive

Pro-active compliance (Product out of EU RoHS legal scope)

Reach regulation

Reference contains Substances of Very High Concern above the threshold

China rohs regulation

X

California proposition 65

WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Others

Legacy weee scope

In

Package 1 bare product quantity

1

Average percentage of recycled plastic content

0 %

At least in Europe

Weee label

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Analogue input number

2

Analogue input type

  • thermocouple - 200...1000 °C with thermocouple J
  • Ni 100/Ni 1000 temperature probe - 60...180 °C
  • Pt 100 temperature probe - 200...850 °C
  • Pt 1000 temperature probe - 200...600 °C
  • thermocouple - 200...1300 °C with thermocouple K
  • thermocouple 0...1760 °C with thermocouple R
  • thermocouple 0...1760 °C with thermocouple S
  • thermocouple 0...1820 °C with thermocouple B
  • thermocouple - 200...400 °C with thermocouple T
  • thermocouple - 200...1300 °C with thermocouple N
  • thermocouple - 200...800 °C with thermocouple E
  • thermocouple 0...2315 °C with thermocouple C

Analogue input resolution

14 bits

Lsb value

0.1 °C

Sampling duration

  • 125 ms, analogue input type: thermocouple
  • 250 ms, analogue input type: temperature probe

Absolute accuracy error

  • +/- 0.1 % of full scale at 25 °C for Pt 100/Pt 1000, Ni 100/ Ni 1000 temperature probe
  • +/- 0.4 % of full scale at 25 °C for thermocouple N - 200...0 °C
  • +/- 0.1 % of full scale at 25 °C for thermocouple N 0...1300 °C
  • +/- 6 °C at 25 °C for thermocouple R, S 0...200 °C
  • +/- 0.1 % of full scale at 25 °C for thermocouple R, S 200...1760 °C
  • +/- 0.1 % of full scale at 25 °C for thermocouple C 0...2315 °C
  • +/- 0.4 % of full scale at 25 °C for thermocouple K - 200...0 °C
  • +/- 0.1 % of full scale at 25 °C for thermocouple K 0...1300 °C
  • +/- 0.4 % of full scale at 25 °C for thermocouple J - 200...0 °C
  • +/- 0.1 % of full scale at 25 °C for thermocouple J 0...1000 °C
  • +/- 0.4 % of full scale at 25 °C for thermocouple E - 200...0 °C
  • +/- 0.1 % of full scale at 25 °C for thermocouple E 0...800 °C
  • +/- 0.4 % of full scale at 25 °C for thermocouple T - 200...0 °C
  • +/- 0.1 % of full scale at 25 °C for thermocouple T 0...400 °C

Temperature drift

+/- 0.02 %FS/°C

Repeat accuracy

+/- 0.5 %FS

Non-linearity

+/- 0.01 %FS

Cross talk

<= 1 LSB

Electrical connection

3 x 1.5 mm² 2 screw terminal blocks with pitch 3.81 mm adjustment for inputs

Maximum cable distance between devices

twisted shielded pairs cable: <30 m for input

Insulation

non-insulated between analogue input and internal logic

Input impedance

>= 1 MOhm

Immunity to microbreaks

10 ms

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

3.500 cm

Package 1 width

4.500 cm

Package 1 length

7.000 cm

Package 1 weight

40.000 g

Total lifecycle carbon footprint

5 kg CO2 eq.

Carbon footprint of the manufacturing phase [a1 to a3]

0.970154321

Carbon footprint of the manufacturing phase [a1 to a3]

1 kg CO2 eq.

Carbon footprint of the distribution phase [a4]

0.0025804321

Carbon footprint of the distribution phase [a4]

0 kg CO2 eq.

Carbon footprint of the installation phase [a5]

0.0000589938

Carbon footprint of the installation phase [a5]

0 kg CO2 eq.

Carbon footprint of the use phase [b2, b3, b4, b6]

3.86275

Carbon footprint of the use phase [b2, b3, b4, b6]

4 kg CO2 eq.

Sustainable packaging

No

Carbon footprint of the end-of-life phase [c1 to c4]

0.0079898148

Carbon footprint of the end-of-life phase [c1 to c4]

0 kg CO2 eq.

Pvc free

Yes

Take-back

No

Product contributes to saved and avoided emissions

No

Removable battery

N/A

Total lifecycle carbon footprint

4.8435335617

Average percentage of recycled metal content

0 %

Packaging made with recycled cardboard

No

Packaging without single use plastic

Yes

Pvc free

Yes

End of life manual availability

ENVEOLI1403017EN

Take-back

No

Weee label

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

Warranty (in months)

18
Show all specifications

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Environmental Disclosure

  • End of Life Manual

  • Installation Instruction

  • Operating Manuals

  • Certificates (MSDS)

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.