Modicon M221 Analogue input cartridge 2 temperature inputs, I/O extension

Home ProductsIndustrialModiconAnalogue input cartridge

Modicon M221 Analogue input cartridge 2 temperature inputs, I/O extension

Item Number: TMC2TI2

Datasheet

Product Dimensions

Width icon

Width35 mm

Height icon

Height41 mm

Depth icon

Depth15 mm

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product Modicon M221
Product or component type analogue input cartridge
Product compatibility Modicon M221C

Physical

Type of cable twisted shielded pairs cable
Height 41 mm
Depth 15 mm
Width 35 mm
Net weight 0.015 kg
Toxic heavy metal free Yes
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP1403017EN
Reach regulation Reference contains Substances of Very High Concern above the threshold
China rohs regulation X
Eu rohs directive Compliant
California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Others

Package 1 bare product quantity 1
Package 2 bare product quantity 75
Package 3 bare product quantity 3600
Average percentage of recycled plastic content 0 %
Legacy weee scope In
At least in Europe
Warranty duration(in months) bmecat 18
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Analogue input number 2
Analogue input type
  • thermocouple - 200...1000 °C with thermocouple J
  • Ni 100/Ni 1000 temperature probe - 60...180 °C
  • Pt 100 temperature probe - 200...850 °C
  • Pt 1000 temperature probe - 200...600 °C
  • thermocouple - 200...1300 °C with thermocouple K
  • thermocouple 0...1760 °C with thermocouple R
  • thermocouple 0...1760 °C with thermocouple S
  • thermocouple 0...1820 °C with thermocouple B
  • thermocouple - 200...400 °C with thermocouple T
  • thermocouple - 200...1300 °C with thermocouple N
  • thermocouple - 200...800 °C with thermocouple E
  • thermocouple 0...2315 °C with thermocouple C
Analogue input resolution 14 bits
Lsb value 0.1 °C
Sampling duration
  • 125 ms, analogue input type: thermocouple
  • 250 ms, analogue input type: temperature probe
Absolute accuracy error
  • +/- 0.1 % of full scale at 25 °C for Pt 100/Pt 1000, Ni 100/ Ni 1000 temperature probe
  • +/- 0.4 % of full scale at 25 °C for thermocouple N - 200...0 °C
  • +/- 0.1 % of full scale at 25 °C for thermocouple N 0...1300 °C
  • +/- 6 °C at 25 °C for thermocouple R, S 0...200 °C
  • +/- 0.1 % of full scale at 25 °C for thermocouple R, S 200...1760 °C
  • +/- 0.1 % of full scale at 25 °C for thermocouple C 0...2315 °C
  • +/- 0.4 % of full scale at 25 °C for thermocouple K - 200...0 °C
  • +/- 0.1 % of full scale at 25 °C for thermocouple K 0...1300 °C
  • +/- 0.4 % of full scale at 25 °C for thermocouple J - 200...0 °C
  • +/- 0.1 % of full scale at 25 °C for thermocouple J 0...1000 °C
  • +/- 0.4 % of full scale at 25 °C for thermocouple E - 200...0 °C
  • +/- 0.1 % of full scale at 25 °C for thermocouple E 0...800 °C
  • +/- 0.4 % of full scale at 25 °C for thermocouple T - 200...0 °C
  • +/- 0.1 % of full scale at 25 °C for thermocouple T 0...400 °C
Temperature drift +/- 0.02 %FS/°C
Repeat accuracy +/- 0.5 %FS
Non-linearity +/- 0.01 %FS
Cross talk <= 1 LSB
Electrical connection 3 x 1.5 mm² 2 screw terminal blocks with pitch 3.81 mm adjustment for inputs
Maximum cable distance between devices twisted shielded pairs cable: <30 m for input
Insulation non-insulated between analogue input and internal logic
Input impedance >= 1 MOhm
Immunity to microbreaks 10 ms
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 3.500 cm
Package 1 width 4.500 cm
Package 1 length 7.000 cm
Package 1 weight 40.000 g
Unit type of package 2 S01
Number of units in package 2 75
Package 2 height 15.000 cm
Package 2 width 15.000 cm
Package 2 length 40.000 cm
Package 2 weight 3.263 kg
Unit type of package 3 P12
Number of units in package 3 3600
Package 3 height 105.000 cm
Package 3 width 80.000 cm
Package 3 length 120.000 cm
Package 3 weight 170.624 kg
Green premium status for reporting Green Premium product
Total lifecycle carbon footprint 5 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 0.970154321
Carbon footprint of the manufacturing phase [a1 to a3] 1 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.0025804321
Carbon footprint of the distribution phase [a4] 0 kg CO2 eq.
Carbon footprint of the installation phase [a5] 0.0000589938
Carbon footprint of the installation phase [a5] 0 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 3.86275
Carbon footprint of the use phase [b2, b3, b4, b6] 4 kg CO2 eq.
Sustainable packaging No
Carbon footprint of the end-of-life phase [c1 to c4] 0.0079898148
Carbon footprint of the end-of-life phase [c1 to c4] 0 kg CO2 eq.
Pvc free Yes
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 4.8435335617
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard No
Packaging without single use plastic Yes
China rohs label 1
Pvc free Yes
End of life manual availability ENVEOLI1403017EN
Take-back No
Weee label The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • Environmental Disclosure

  • End of Life Manual

  • Installation Instruction

  • Operating Manuals

  • Certificates (MSDS)

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.