Harmony Control Relays Modular 1 phase Voltage Control Relay 5A, 1CO, 9…15V DC

Home ProductsIndustrialHarmonyModular 1 phase Voltage Control Relay

Harmony Control Relays Modular 1 phase Voltage Control Relay 5A, 1CO, 9…15V DC

Item Number: RM17UAS14

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product Harmony Control Relays
Product or component type voltage control relay
Warranty 18 months

Physical

Connections - terminals screw connectors
[in] rated current 5 A
Insulation resistance
  • > 500 MOhm at 500 V DC conforming to IEC 60255-5
  • > 500 MOhm at 500 V DC conforming to IEC 60664-1
Local signalling
  • LED (green) for power ON
  • LED (yellow) for relay ON
Connections - terminals
  • screw terminals, 1 x 0.5...1 x 4 mm² (20 AWG...11 AWG) solid without cable end
  • screw terminals, 2 x 0.5...2 x 2.5 mm² (20 AWG...14 AWG) solid without cable end
  • screw terminals, 1 x 0.2...2 x 2.5 mm² (24 AWG...12 AWG) flexible with cable end
  • screw terminals, 2 x 0.2...2 x 1.5 mm² (24 AWG...16 AWG) flexible with cable end
Mounting support 35 mm symmetrical DIN rail conforming to IEC 60715
Electrical durability 100000 cycles
Mechanical durability 30000000 cycles
Control type without test button
Width 17.5 mm
Net weight 0.08 kg
Ambient air temperature for operation -20...50 °C
Standards IEC 60255-6
Product certifications
  • CSA
  • C-Tick
  • GL
  • UL
  • GOST
Ambient air temperature for storage -40...70 °C
Relative humidity 95 % at 55 °C conforming to IEC 60068...2-30
Ip degree of protection
  • IP20 (terminals) conforming to IEC 60529
  • IP30 (casing) conforming to IEC 60529
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP1504008EN
Eu rohs directive Compliant By Exemption
California proposition 65 WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Others

Average percentage of recycled plastic content 0 %
At least in Europe
Warranty duration(in months) bmecat 18
Weee label No
Package 1 bare product quantity 1
Legacy weee scope Out
Relay type voltage control relay
Product specific application for single-phase and DC supply
Relay name RM17UAS
Relay monitored parameters overvoltage or undervoltage detection
Time delay type adjustable 0.1...10 s, 0 + 10 % Tt- time delay upon fault
Switching capacity in va 1250 VA
Measurement range 9...15 V DC
Contacts type and composition 1 C/O
[uc] control circuit voltage 110...240 V
Reset time 1500 ms time delay
Maximum switching voltage 250 V AC/DC
Minimum switching current 10 mA at 5 V DC
Maximum switching current 5 A AC/DC
Supply voltage limits 7...20 V DC
Maximum power consumption in w 1 W DC
Output contacts 1 C/O
Nominal output current 5 A
Hysteresis 5...20 % of threshold setting
Measurement accuracy +/- 10 % of the full scale value
Polarity non reversible polarity on DC supply
Run-up delay at power-up 1000 ms DC
Repeat accuracy
  • +/- 0.5 % for input and measurement circuit
  • +/- 1 % for time delay
Measurement error < 1 % over the whole range with voltage variation
Quality labels CE
Operating position any position without derating
Overvoltage category III conforming to IEC 60664-1
[ui] rated insulation voltage
  • 250 V conforming to IEC 60664-1
  • 400 V conforming to IEC 60664-1
Tightening torque 0.6...1 N.m conforming to IEC 60947...1
Housing material polycarbonate
Operating rate <= 360 operations/hour full load
Utilisation category
  • AC-12 conforming to IEC 60947-5-1
  • AC-13 conforming to IEC 60947-5-1
  • AC-14 conforming to IEC 60947-5-1
  • AC-15 conforming to IEC 60947-5-1
  • DC-12 conforming to IEC 60947-5-1
  • DC-14 conforming to IEC 60947-5-1
[us] rated supply voltage , self-powered
Compatibility code RM17
Electromagnetic compatibility
  • emission standard for industrial environments conforming to IEC 61000-6-4
  • emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3
  • immunity for industrial environments conforming to NF EN/IEC 61000-6-2
Vibration resistance
  • 0.35 mm (f= 5-57.6 Hz) conforming to IEC 60068-2-6
  • 1 gn (f= 57.6-150 Hz) conforming to IEC 60255-21-1
Shock resistance 5 gn conforming to IEC 60068-2-27
Pollution degree 3 conforming to IEC 60664-1
Directives
  • 73/23/EEC - low voltage directive
  • 89/336/EEC - electromagnetic compatibility
Dielectric test voltage
  • 2 kV, 1 min AC 50 Hz conforming to IEC 60255-5
  • 2 kV, 1 min AC 50 Hz conforming to IEC 60664-1
Non-dissipating shock wave
  • 4 kV conforming to IEC 60255-5
  • 4 kV conforming to IEC 60664-1
  • 4 kV conforming to IEC 61000-4-5
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 2.600 cm
Package 1 width 8.000 cm
Package 1 length 9.600 cm
Package 1 weight 85.900 g
Unit type of package 2 S02
Number of units in package 2 48
Package 2 height 15.000 cm
Package 2 width 30.000 cm
Package 2 length 40.000 cm
Package 2 weight 4.492 kg
Green premium status for reporting Green Premium product
Total lifecycle carbon footprint 23 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 1.7374334850777773
Carbon footprint of the manufacturing phase [a1 to a3] 2 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.22642907320932312
Carbon footprint of the distribution phase [a4] 0.2 kg CO2 eq.
Carbon footprint of the installation phase [a5] 0.0003431237379090404
Carbon footprint of the installation phase [a5] 0 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 21.204408344913805
Carbon footprint of the use phase [b2, b3, b4, b6] 21 kg CO2 eq.
Sustainable packaging Yes
Carbon footprint of the end-of-life phase [c1 to c4] 0.20702328942246598
Carbon footprint of the end-of-life phase [c1 to c4] 0.2 kg CO2 eq.
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 23.37563731636128
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard Yes
Packaging without single use plastic Yes
Scip number 5e3fdf99-611b-4d07-ad17-6eba84ab488b
End of life manual availability ENVEOLI1504008EN
Take-back No
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • CAD Files and Packs

  • Technical Data Catalogues

  • End of Life Manual

  • Environmental Disclosure

  • Installation Instruction

  • Technical illustration

  • Application Notes

  • eTechPub

  • Certificates (MSDS)

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)

Important: Some software files may need a mySchneider or Club login to download.