Colour ()
- 1 PCE 0
Acti9 Reflex iC60H Ti24 16 A 4P curve C integrated control MCB
Item Number: A9C65416
Colour ()
- 1 PCE 0
Datasheet
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| - | |||
| - | |||
| - |
Barcode
| Qty | UoM | EAN | Colour |
|---|---|---|---|
| 1 | PCE | 3606480455162 | - |
Specifications
Design
| Device application |
|
|---|---|
| Range | Acti9 |
| Range of product | Reflex iC60 |
| Product or component type | integrated control circuit breaker |
| Product compatibility | with PLC |
| Market segment |
|
| Warranty | 18 months |
Physical
| [in] rated current | 16 A |
|---|---|
| Control type |
|
| Control signal type |
|
| Local signalling |
|
| Mounting mode | fixed |
| Mounting support | 35 mm symmetrical DIN rail |
| Height | 84 mm |
| Width | 117 mm |
| Depth | 77 mm |
| Mechanical durability | 50000 cycles |
| Electrical durability | AC-1: 50000 cycles AC 50 Hz |
| Ip degree of protection | IP20 conforming to IEC 60529 |
| Relative humidity | 93 % at 40 °C |
| Mercury free | Yes |
| Rohs exemption information | Yes |
| Environmental disclosure | ENVPEP1107022EN |
| Reach regulation | Reference contains Substances of Very High Concern above the threshold |
| China rohs regulation | Product out of China RoHS scope |
| Eu rohs directive | Compliant By Exemption |
Others
| Legacy weee scope | In |
|---|---|
| Package 1 bare product quantity | 1 |
| Package 2 bare product quantity | 14 |
| Average percentage of recycled plastic content | 0 % |
| At least in Europe | |
| Warranty duration(in months) bmecat | 18 |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Product name | Reflex iC60 |
| Device short name | Reflex iC60H |
| Poles description | 4P |
| Number of protected poles | 4 |
| Network type | AC |
| Trip unit technology | thermal-magnetic |
| Curve code | C |
| Network frequency | 50/60 Hz |
| Breaking capacity code | H |
| Breaking capacity |
|
| [ui] rated insulation voltage | 500 V AC |
| Contact position indicator | yes |
| [uc] control circuit voltage |
|
| [us] rated supply voltage | 230 V AC at 50/60 Hz |
| 9 mm pitches | 13 |
| Total power losses | 6.3 W |
| Power losses per pole | 2.1 W |
| Provision for padlocking | padlockable |
| Locking options description | padlock in OFF position |
| Earth-leakage protection | separate block |
| Compatibility code | Reflex_iC60 |
| Pollution degree | 3 |
| Tropicalisation | 2 |
| Unit type of package 1 | PCE |
| Number of units in package 1 | 1 |
| Package 1 height | 9 cm |
| Package 1 width | 11.2 cm |
| Package 1 length | 16.5 cm |
| Package 1 weight | 796 g |
| Unit type of package 2 | S03 |
| Number of units in package 2 | 14 |
| Package 2 height | 30 cm |
| Package 2 width | 30 cm |
| Package 2 length | 40 cm |
| Package 2 weight | 11.593 kg |
| Green premium status for reporting | Green Premium product |
| Total lifecycle carbon footprint | 48 kg CO2 eq. |
| Carbon footprint of the manufacturing phase [a1 to a3] | 11.414179288904217 |
| Carbon footprint of the manufacturing phase [a1 to a3] | 11 kg CO2 eq. |
| Carbon footprint of the distribution phase [a4] | 0.10813302148557982 |
| Carbon footprint of the distribution phase [a4] | 0.1 kg CO2 eq. |
| Carbon footprint of the installation phase [a5] | 0.059477685209644054 |
| Carbon footprint of the installation phase [a5] | 0.1 kg CO2 eq. |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 33.460332753541444 |
| Carbon footprint of the use phase [b2, b3, b4, b6] | 33 kg CO2 eq. |
| Sustainable packaging | Yes |
| Carbon footprint of the end-of-life phase [c1 to c4] | 2.528972848372407 |
| Carbon footprint of the end-of-life phase [c1 to c4] | 3 kg CO2 eq. |
| Pvc free | No |
| Halogen-free status | Product contains halogen above thresholds |
| Silicone-free | No |
| Energy efficiency optimized | False |
| Take-back | No |
| Product contributes to saved and avoided emissions | No |
| Removable battery | N/A |
| Total lifecycle carbon footprint | 47.57109559751329 |
| Average percentage of recycled metal content | 0 % |
| Packaging made with recycled cardboard | Yes |
| Packaging without single use plastic | Yes |
| Scip number | 8e8587cb-1e8e-4934-ae0d-4f8ec8c2b050 |
| Halogen-free status | Product contains halogen above thresholds |
| Pvc free | No |
| Silicone-free | No |
| End of life manual availability | N/A |
| Take-back | No |
| Weee label | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| Warranty (in months) | 18 |
Documents & downloads
-
All
-
CAD Files and Packs
-
Product Brochures
-
Environmental Disclosure
-
Installation Instruction
-
Operating Manuals
-
Certificates (MSDS)
-
Declaration of Conformity
-
Declaration of Conformity (Sustainability)
Smart Panels: Embrace the future of power distribution (eBrochure)
VERSION
1.0
DATE
17 Apr 2019
REVISION
1.0
Smart Panels - Connect your buildings to energy savings
VERSION
1.0
DATE
26 May 2016
REVISION
1.0
Smart Panels - Connect your buildings to energy savings
VERSION
1.0
DATE
06 Mar 2016
REVISION
1.0
Acti9 Smartlink Ethernet Communication System - User Manual
VERSION
2.1
DATE
27 Jun 2024
REVISION
2.1
Acti 9 Smartlink Modbus Communication System - User Manual
VERSION
2.1
DATE
26 Jun 2024
REVISION
2.1
Acti9 Smartlink Modbus - User Manual
VERSION
1.0
DATE
18 Jun 2024
REVISION
1.0
Reflex iC60 Integrated Control Circuit-Breakers - Reference Manual
VERSION
1.0
DATE
29 Sep 2023
REVISION
1.0
CCA Certificate
VERSION
1.0
DATE
20 May 2026
REVISION
1.0
CEBEC certificate
VERSION
2.0
DATE
25 Oct 2025
REVISION
2.0
CCC_ Reflex iC60N iC60H_ 塑料外壳式断路器_SAS
VERSION
1.0
DATE
16 Jul 2025
REVISION
1.0
CEBEC certificate
VERSION
1.0
DATE
23 Feb 2024
REVISION
1.0
NF certificate LCIE
VERSION
1.0
DATE
23 Feb 2024
REVISION
1.0
A9C65416 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
A9C65416 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
A9C65416 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
A9C65416 EU RoHS Directive
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
A9C65416 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
A9C65416 REACh Regulation
VERSION
1.0
DATE
01 Jan 1900
REVISION
1.0
Recently viewed
DISCONTINUED
A9C65416
Acti9 Reflex
iC60H Ti24 16 A 4P curve C integrated control MCB
DISCONTINUED
ZB4BV063
Harmony XB4 Head for Pilot light
metal, blue, 22mm, universal LED, plain lens
DISCONTINUED
220S50
Clipsal - Cable Management Conduit Plug
Screwed, PVC, 50mm
DISCONTINUED
GVAS225
TeSys GV2 Shunt release (MX)
TeSys Deca,220-240V AC 50Hz
DISCONTINUED
2036VH
2000 Series Flush Surround and Grid Plate
6 Gang, Vertical/Horizontal Mount, Standard Size
DISCONTINUED
230DRAQ
Resi MAX Meter Boxes Metal Meter Box
Switch Board, Din Rail, 21 Module, H680 x W470 x D280mm
DISCONTINUED
56C320F
Clipsal - 56 Series Switched Socket Outlet
250V, 20A, 3 Flat PIN, IP66, 1 Pole
DISCONTINUED
MDECLRGNRL4530
Clipsal - Cable Management GN CBL Ladder Reduce Lh
450-300mm
DISCONTINUED
GV2APN02
TeSys GV2 Extended rotary handle kit
TeSys Deca, IP54, red handle, with trip indication, for GV2L-GV2P
DISCONTINUED
501
Clipsal - Lighting Lampholder
BC, 3 Piece Cord Grip, 250V 3A
DISCONTINUED
MM10SW-36
OptiLine Socket Fascia Assembly
Twin, with Round Earth
DISCONTINUED
ISM11406P
OptiLine 70 joint cover piece
155 x 55mm, PC/ABS, polar white
DISCONTINUED
LA9D4002
TeSys D Mechanical and electrical interlock
TeSys Deca reversing & changeover, 2 Contactors LC1D80-D95 AC coil
DISCONTINUED
ZB4BV063
Harmony XB4 Head for Pilot light
metal, blue, 22mm, universal LED, plain lens
DISCONTINUED
2036VH
2000 Series Flush Surround and Grid Plate
6 Gang, Vertical/Horizontal Mount, Standard Size
DISCONTINUED
230DRAQ
Resi MAX Meter Boxes Metal Meter Box
Switch Board, Din Rail, 21 Module, H680 x W470 x D280mm
DISCONTINUED
56C320F
Clipsal - 56 Series Switched Socket Outlet
250V, 20A, 3 Flat PIN, IP66, 1 Pole
DISCONTINUED
GV2APN02
TeSys GV2 Extended rotary handle kit
TeSys Deca, IP54, red handle, with trip indication, for GV2L-GV2P
DISCONTINUED
LA9D4002
TeSys D Mechanical and electrical interlock
TeSys Deca reversing & changeover, 2 Contactors LC1D80-D95 AC coil