C-Bus Home Controller SpaceLogic IP, Free Standing, 24V DC

C-Bus Home Controller SpaceLogic IP, Free Standing, 24V DC

Item Number: 5200WHC2

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product SpaceLogic C-Bus
Product or component type system controller
Product compatibility IP device

Physical

Supply DC extension cable
Communication network type
  • C-Bus
  • E-LAN
Connector type
  • USB
  • HDMI
  • RJ45
  • bus
Type of cable CAT5 category 5e RJ45
Mounting mode free standing
Length 219 mm
Width 175 mm
Height 33.5 mm
Ambient air temperature for operation 0...45 °C
Relative humidity 10...90 % without condensation
Mercury free Yes
Rohs exemption information Yes
Environmental disclosure ENVPEP2201001_V1
Reach regulation Reference contains Substances of Very High Concern above the threshold
China rohs regulation Product out of China RoHS scope
Eu rohs directive Compliant By Exemption

Others

Legacy weee scope In
Package 1 bare product quantity 1
Average percentage of recycled plastic content 0 %
Outside of Europe
Weee label N/A
Weee applicability Finished product
Warranty duration(in months) bmecat 18
Device short name WHC2
Ethernet service
  • dynamic DNS
  • DHCP client
Clock drift
  • 1 min/month
  • 1 s/1000 years NTP
[us] rated supply voltage
  • input: 24 V DC, <1 A
  • communication bus: 15...36 V DC, <0.036 A
Mounting location indoor use only
Unit type of package 1 PCE
Number of units in package 1 1
Package 1 height 7.8 cm
Package 1 width 27.2 cm
Package 1 length 29.6 cm
Package 1 weight 1.186 kg
Total lifecycle carbon footprint 0.3 kg CO2 eq.
Carbon footprint of the manufacturing phase [a1 to a3] 0.01537649
Carbon footprint of the manufacturing phase [a1 to a3] 0 kg CO2 eq.
Carbon footprint of the distribution phase [a4] 0.00015302365000000002
Carbon footprint of the distribution phase [a4] 0 kg CO2 eq.
Carbon footprint of the installation phase [a5] 0.00001676411
Carbon footprint of the installation phase [a5] 0 kg CO2 eq.
Carbon footprint of the use phase [b2, b3, b4, b6] 309.57644578313256
Carbon footprint of the use phase [b2, b3, b4, b6] 310 kg CO2 eq.
Sustainable packaging No
Carbon footprint of the end-of-life phase [c1 to c4] 0.0006186274833333333
Carbon footprint of the end-of-life phase [c1 to c4] 0 kg CO2 eq.
Pvc free No
Halogen-free status Halogen free product
Silicone-free  No
Take-back No
Product contributes to saved and avoided emissions No
Removable battery N/A
Total lifecycle carbon footprint 0.3221296258256626
Average percentage of recycled metal content 0 %
Packaging made with recycled cardboard Yes
Packaging without single use plastic No
Halogen-free status Halogen free product
Pvc free No
Silicone-free No
End of life manual availability ENVEOLI2201001_V1
Take-back No
Warranty (in months) 18

Documents & downloads

Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Environmental Disclosure

  • End of Life Manual

  • Operating Manuals

  • Specification Guide

  • Application Notes

  • Declaration of Conformity

  • Declaration of Conformity (Sustainability)

  • Software - Release

  • Software - Data Library

  • Firmware

Important: Some software files may need a mySchneider or Club login to download.

Frequently Asked Questions

Wiser2 apps Security Update notice

Hide Show
A security update notice will come up like the image below. This is a Wiser2 apps Security Update notice.

1 apps show up with notification

 

 

 

Dear SpaceLogic C-Bus Community,

We want to notify you about a critical security update for the Wiser 2 app. This update will affect users as the app will no longer support the unsecured Remote Connection feature, which allows connection to the mobile app from outside the home.

Users of the Wiser 2 app will receive a push notification about this update in early January 2024, and the new app with the security update will be available for download in February 2024.

This update impacts Wiser 1, Wiser 1.5, Wiser MK II, and SpaceLogic C-Bus Home Controller users, with actions varying depending on the controller installed in the system.

The push notification that will be sent to Wiser 2 app users in early January, will guide them to a non-indexable web page for details based on the controller they have in their installations. Please refer to the following link for more information:

https://www.clipsal.com/wiser-customer-support/wiser-c-bus-security-update

We kindly request that you disseminate this information to your customer support teams.

Thank you,

How to change the order of the Schedule in PICED so it sits in the correct order that you want on the wiser2 apps

Hide Show

Wiser2 apps Widget/Schedule not in order.

To change the order of the widget display in wiser2 apps.

PICED> In widget manager

  1. Aligning them from low to high by clicking the number column
  2. Highlight the widget  then drag and drop the widget in the order that you please

collum

 

The order can also be change for scheduler

  1.  Aligning the Schedules from low to high by clicking the number column
  2. Highlight the schedule widget  then drag and drop the widget in the order that you please

collums


 

Wiser2/SLHC Remote Connection for PICED 1.14.2 onward

Hide Show

In the new Firmware Wiser 2 will only be able to connect remotely using SSL/HTTPS (Port 443 or the External Port that is defined in PICED)  

This means HTTP or Port 80 will now longer allow you to login remotely

Whenever you change the remote connection setting, it will force a reboot of the Wiser 2

              Wiser 2 with WiFi – wiser2firmware_1_33_1.img, Wiser 2 without WiFi – SLHomeControllerFirmware_2_01_1.img

5200WHC2 Wiser 2 Security Enhancements PICED 1.14.2 onward

Hide Show

New Password Rules for Wiser 2
 

  • Passwords must be at least 8 characters and not more than 64 characters in length.
  • Passwords must contain 1 upper case and 1 lower case.
  • Passwords must contain 1 number or 1 special character.
  • Passwords must not contain spaces at the beginning or end.
  • Passwords must not contain usernames in them.
  • Passwords must not be the same as existing passwords.
    • Added one more point for mobile and web clients (not applicable for PICED).

SSL Certificates (TLS)

  1. Uploading Signed Certificate (purchased from DigiCert, GeoTrust, RapidSSL, ZeroSSL)
  2. Let's Encrypt (Must have a DNS for their domain)
  3. Self-Sign Certificate

Wiser2 and C-Bus Home Controller (SLHC) both have same part number (5200whc2) but hold a different firmware

Hide Show

Both wiser have the same part number(5200WHC2) but different Device type

SE.com link to the latest PICED 4.15.2
https://www.se.com/au/en/product-range/2216-spacelogic-cbus-home-automation-system/#software-and-firmware

Old Wiser2 
Wiser 2 with WiFi – wiser2firmware_1_33_1.img

Current C-Bus Home Controller (SLHC)
Wiser 2 without WiFi – SLHomeControllerfirmware_2_01_1.img

Firmware update is done via PICED but Alternatively, you can use the option Wiser Manual Update under the Settings from the Web Client and then choose one of the above files for the upgrade.

manual F/W update
manual F/W update link

 

What Class is Wiser2/SLHC (5200WHC22) Network Support?

Hide Show

Unfortunately, to be able to disable the remote connection for Projector Control Wiser 2 only supports class C network.

A class C network would have a subnet mask of 255.255. 255.0, which means that 24 bits are used for the network. In CIDR notation, this is designated by a /24 following the IP address


 

What is new of the C-Bus PICED 4.14.2?

Hide Show
What is new of the C-Bus PICED 4.14.2?
  • C-Bus PICED 4.14.2 was released on 26/06/2023
Security Enhancements
PICED now provides improved security for Wiser 2 and C-Bus Home Controller projects. The requirements for profile passwords have been strengthened, as has their storage. Our recommendation is to update your Wiser 2 and C-Bus Home Controller projects to take advantage of these security fixes.

Note: that your Wiser 2 and C-Bus Home Controller projects cannot be rolled back to their previous versions once updated.

Transfer Utility now provides improved security for Wiser 2 and C-Bus Home Controller projects while transferring and retrieving project data, and while updating firmware. Port 80 is blocked for remote transfer and is supported by local transfer only. Remote transfer uses port 443 by default.

Let’s Encrypt is now supported for providing secure connections. To enable Let’s Encrypt, the C-Bus Home Controller DNS name can be provided while specifying project details. Secure connection details can be provided on the Transfer Project screen.

• SP-3869 – Implement support of password hashing for Wiser 2 / C-Bus Home Controller projects
• SP-3871 – Implement password hashing in Transfer Utility for Wiser2 and Home Controller units
• SP-3872 – Implement stricter password validation rules
• Capture the DNS name as part of PICED
• Upload CA certificate in PICED
• Fixed the SocketException error trying to transfer a project when Projector Control is disabled
• Fixed an issue that meant upgrading Wiser 2 firmware locally did not work
• Fixed an authentication issue when trying to do a firmware update
• Fixed an issue where transfer was unable to be done on any port other than 80
• Implemented a better workflow when opening a project that has passwords that don't meet the password requirements
• Fixed the failure to authenticate when trying to upgrade the firmware
• Fixed an issue where changes to the CNI port were not being saved
• Fixed an issue where most users in the profiles have been replaced with default Admin profiles

Wiser 2 / C-Bus Home Controller Firmware
This version of PICED includes the following new versions of the Wiser 2 and C-Bus Home Controller firmware:
1.33.1 (Wiser 2)
2.01.1 (C-Bus Home Controller)

Other Fixes
• SP-3867 – Edit Total Power Meter history does not distribute the data to the meter correctly
• SP-3876 – Unable to transfer the Old Flash Wiser 2 Project remotely
• Fixed an issue with refreshing project from the unit not working
• Fixed an issue where a remote firmware upgrade on port 85 would fail

The latest C-Bus software from SE Ecoxpert
https://ecoxpert.se.com/en/spacelogic-c-bus/software-and-firmware/software#tab/documents
 

Where to download the C-Bus PICED 4.14.2?

Hide Show
Where to download the C-Bus PICED 4.14.2?

Date: 29/06/2023
Version: V4.14.2
Reference: PICED-V4.14.2
Operating Systems:  Windows 10, Windows 7, Windows 8, Windows Vista, Windows x86 / x64

It contains C-Bus Wiser 2 firmware V1.33.1 and C-Bus Home Controller firmware V2.01.1

https://www.se.com/za/en/download/document/PICED-V4.14.2/
 

How to reset wiser2 back to factory default?

Hide Show

There are several reasons why you may wish to restart or reset the Wiser 2. If the unit is not communicating properly, a restart (turning power on and off)might be all that is required but for a full factory reset.

NOTE: Performing a Factory "Full" Reset will wipe any programming of the unit and reset the ip addressing to DHCP and the username and password to default - "default"
 

If a Factory Reset is required follow these steps:
(1) Power OFF the Wiser 2
(2) Press and hold the reset button
(3) While the button is pressed, apply power to Wiser 2
(4) After 25Sec, release the button and allow the Wiser 2 to reboot.

WISER 2

Where to download the C-Bus Toolkit 1.16.2 and PICED 4.14.1?

Hide Show

Where to download the C-Bus Toolkit 1.16.2 and PICED 4.14.1?


C-Bus Toolkit Software and Release Notes - V1.16.2, released on 07/06/2022
https://www.se.com/ww/en/download/document/C-Bus_Toolkit_V1.16.2/


PICED_V4.14.1 Programming Interface for C-Bus Embedded Devices, released on 05/09/2022
https://www.se.com/sg/en/download/document/PICED_V4.14.1/

Note: PICED_V4.14.1 comes with the new C-Bus Wiser 2 firmware 1.32.35 and Home Controller firmware 2.00.24.