Cortex Meter Contactor Specifications

FAQ000283206

05 August 2026

Contactors can be supplied by various OEMs; however, the following specifications are strongly recommended to ensure reliable service of the Clipsal Cortex load control application:

  • Suitable Nominal current ranges from 25A upwards for loads
    • Resistive loads including 3.6 kW or 4.8 kW heating element/s expected in 315L & 400L tanks
  • Reasonable current de-ratings as per AC-1, AC-7a & AC-7b
    • AC-1: Non-inductive or slightly inductive loads, example: resistive furnaces, heaters
    • AC-7a: Slightly inductive loads in household appliances: examples: mixers, blenders
    • AC-7b: Motor-loads for household appliances: examples: fans, central vacuum
  • Compliance to IEC/EN 61095 & RCM approval
    • Rated for 100,000 electrical coil operations
    • Rated for 1,000,000 mechanical operations
  • 1 Normally Closed Contact (NC) + 1 Normally Open Contact (NO)
  • Coil Voltage of 240Vac
  • 1 pole (18mm) width to save space
  • Manual Override switch (I / Auto / O)
  • RCM approval
  • Hum Free contactors are not supported (Example Voltex Contactors MC-25-240-R-1NO1NC)
;