cover pvc 2aperture 116x73

P2000 Series, Flush Plates - Moulded, Switch Plate - 2 Gang

Catalogue Number: P2002
cover pvc 2aperture 116x73
Colour: White Electric
Colour: Per UOM Std.
  • Cream 1 PCE
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
Prestige Series P2000
Product brand
Clipsal
Number of gangs
2 gangs
Product destination
switch
Material
plastic
Marking
without marking
Mounting position
vertical
Length
116 mm
Width
73 mm
Depth
12 mm
Sustainable offer status
Green Premium product
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Environmental Disclosure
ENVPEP121018EN
Circularity Profile
N/A

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Product Environmental

  • Installation Instruction

  • Specifications

  • Certificates (MSDS)

Frequently Asked Questions

hide show

What are the dimensions of the P2001?

The dimensions of the P2001 are 116mm long x 73nn wide and 12mm deep.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=P2001
 

What is the alternate to P2032E450UD, Prestige P2000, 450W Universal rotary dimmer?

P2032E450UD, Prestige P2000, 450W Universal rotary dimmer can be assembled with the below components:
P2032VH - P2000 Series, Grid and Cover Assembly - No Mechanisms, Standard size - 2 Gang Grid Assembly
P30M - Switch Mechanism - P2000 Series, 250V 10A - 2 way / 5 terminal.
P2032E450UDM - Light Dimmer Mechanism, P2000 Series, 250V 450W - Universal.
For further information, please visit
https://www.clipsal.com/Trade/Products/ProductDetail?catno=P2032VH
https://www.clipsal.com/Trade/Products/ProductDetail?catno=P30M
https://www.clipsal.com/Trade/Products/ProductDetail?catno=P2032E450UDM



 

What is the part number of the wall clip suitable for large format Prestige P2000 plates?

The part number for the wall clip suitable for large format Prestige P2000 plaes is 154/2.

Whats are the dimensions of the T200, T200FA, T200F, T200X, T200L, T200S

 210 x 158 x 112mm (L x D x W) 

What is the part number for a Prestige P2000 variable fan controller assembled on a plate?

P2032E500F is P2000 Series, Modular Fan Speed Controllers - 250V 500W, Electronic.
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=P2032E500F



 

How to fix a 0023 Bus voltage high error on a GT inverter?

Issue:
Unit keeps faulting with a bus voltage high

Product Line:
GT Series: GT100, GT250 and GT500

Environment:

Cause: 
Lightning strike near by, loose connection on the CCU board connector P3 & P1002 or CCU board issue.

Resolution:
Check for loose connections at the CCU board at P3 and P1002 connectors. Try to clear the fault by pressing F1. If it can not be cleared, then call 866-519-1470 and select option 3 and 3 to open a new case. It is possible that it could be a CCU board issue.
Note: Make sure you check the array first and confirm there are no issues there.

What types of IPAQ devices work ok with Power Suite. 19xx? 22xx? 55xx?

Goals and Symptoms

What types of IPAQ devices work ok with Power Suite. 19xx? 22xx? 55xx?

Facts and Changes

Power Suite and pocket PC

Causes and Fixes

IPAQ3900-3800 séries are not supported by version 1.4 of Powersuite it's a mistake in the VVD info 179

More clearly:

Powersuite v1.5 works under Pocket PC, Pocket PC2002 and it need a serial link. Don't work for the moment under Pocket PC2002, 2003 and Phone Edition.

IPAQ 19xx, 22xx, 55xx don't have serial link and Powersuite don't work on it.
 


Legacy KB System (APS) Data: RESL157483 V1.0, Originally authored by on , Last Edited by on
Related ranges: Other VVD PRODUCTS

What types of IPAQ devices work ok with Power Suite. 19xx? 22xx? 55xx?

Goals and Symptoms

What types of IPAQ devices work ok with Power Suite. 19xx? 22xx? 55xx?

Facts and Changes

Power Suite and pocket PC

Causes and Fixes

IPAQ3900-3800 séries are not supported by version 1.4 of Powersuite it's a mistake in the VVD info 179

More clearly:

Powersuite v1.5 works under Pocket PC, Pocket PC2002 and it need a serial link. Don't work for the moment under Pocket PC2003 and Phone Edition.

IPAQ 19xx, 22xx, 55xx don't have serial link and Powersuite don't work on it.
 


Legacy KB System (APS) Data: RESL157484 V1.0, Originally authored by on , Last Edited by on
Related ranges: Other VVD PRODUCTS

Is there an alternative for P2031VRJ (internet jack in a P2000 Prestige series plate)?

Yes, however you will require these three components:
Part Description Part Number
P2000 Prestige Series plate P2031VH
P2000 Prestige pannel mounting clip P30Z
Cat 6a UTP Connector Mechanism To fit 30 Mech 30RJ45SMA6A

 

Is there a blank plate in the P2000 Prestige Series?

Unfortunately we don't actually make blank plates in the Prestige Series. However, we do offer a plug that fits where the switch mechanism mounts. The part number is P30P.
 

 

 
For further information on this product please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=P30P 

Does a 08002 come with a key

 No, 08002 is supplied without a door, the 08082 door comes with a lockable handle and set of keys

Where can I find B200 series IO specifications and wiring diagrams?

Please see attached file.

Is there a cover only available for P2032/VA?

Yes, the part name for a cover for P2032/2VA is a P2002/2 or  P2002/2M for the metal finish. Prestige P2000 series covers can be purchased separately for choice and convenience.
Covers are available in moulded plastic and metal finishes, suitable either for vertically or horizontally mounted prestige products.

For further information. please visit https://www.clipsal.com/Trade/Products/ProductDetail?CatNo=P2002/2

User-added image

What is the part number of the 30M adaptor to suit Prestige?

The part number is P30Z .It takes any 30 series mechs.
Please click this link for more information
https://www.clipsal.com/Trade/Products/ProductDetail?catno=P30Z

Key Features

  • Mounting accessories
  • Switch mechanisms
  • Prestige panel
  • Suitable for mounting standard Clipsal 30 series mechanisms to the Prestige P2000 collection
  • Dimensions: 38 mm Length x 38 mm Width x 18 mm Depth
User-added image
 

Why is my HomeSafe alarm showing armed even when i enter the confirmed correct code to disarm.

1. Enter Program Mode - P [Master Code - 123(default)] E
2. Enter Installer Mode - P [Installer Code - 000000(default) E
3. Enter P201E Exclude E to display the Master Code Options
4. Has P201E been enabled for Area 1 eg 1E? See installation guide note "1E AREA 1 CODES. This option is used to assign any user code
to area 1. (user codes 1–15 are assigned to area 1.)"
5. Has P201E been enabled for Arm Only eg 3E? This option is only applicable to user codes 2-56 eg P202E - P256E. 
6. Has P201E been enabled for Remote eg 5E? It is recommended that the remote be activated on another user code other than the master as the master can be used to access the program and installer modes.

If Master Code is defined for Area 1 and not for Remote it should be able to arm/disarm from keypad as expected

Where can you find the date code on enclosures for molded case circuit breakers?

Issue:
Where is the date code on Square D circuit breaker enclosures?

Product Line:
Circuit Breaker Enclosures

Environment:  
Circuit Breaker Enclosures for Powerpact and Legacy Molded Case Circuit Breakers

Cause:
Identify Date Code

Resolution:
The date code will be an ink stamp, normally located on the inside surface of the enclosures rear wall, towards the top endwall. It will be a 5 or 6 digit code. First two digits indicate the year it was built, the 2nd two digits indicate the week of the year, the 5th digit indicates the day of the week and the 6th digit (if used) indicates the shift. e.g. 083243 would indicate that enclosure was built by 3rd shift on Thursday, August 7, 2008.

What are the part numbers for Brushed Aluminium covers for the 1/2/3 gang architrave switches in the C2000 series?

The part numbers would be  C2001C-BA for single gang, C2002C-BA for double gang and C2003C-BA for triple.
These also come in a labelled version.

For more information, visit the website at https://www.clipsal.com/Trade/search-results?q=c2001c and click on the link to view a brochure.

What is the part number for the cover of the C2032 white

  C2032C-WE

Do you have a weatherproof cover that can be used with a C2032 plate?

Yes, the part name is 223H-WE.

 

What is error number 19002 on a Sy/Max PLC?

An error number 19002 is a slot error. 190EE where EE points to the slot number experiencing the error so 19002 points to slot number 2. POSSIBLE CAUSES below:
1) Improper rack addressing in which remote drops are assigned to a slot which contains a LI or LTI card.
2) Improper seating of module in rack, edge connector of module may be damaged or the rack or slot has been damaged.

What is the procedure to recover from a 0200h stop code from a Quantum CPU?

A 0200h Stop Code is defined as a bad power down checksum.
1. Reload the program and start the controller
2. Cycle power to the PLC to see if it continues to run.
3. If the controller fails again, reflash the executive and repeat steps 1 and 2.
4. If the controller fails again, replace the Power Supply.
5. If the controller fails again, replace the CPU.

Under no circumstances should a restart command be issued to the controller after a 0200 stop code.
The controller has failed self diagnostics and the problem must be addressed.


.

What cables and adapters need to be used for serial communication conversion from 25 pin to 9 pin when migrating Pro-face legacy GP2000 series to GP3000 and GP4000 series?

This is for RS422/RS485 only.
From GP2000 to GP3000 COM1:  PFXZCBCBCVR41 or PFXZC3CBCVR41 + PFXZC3ADCM1
From GP2000 to GP4000 COM1 & COM2:  PFXZCBCBCVR41
From GP2000 to GP3000 COM2:  PFXZC3CBCVR41
Note that PFXZCBCBCVR41 and PFXZC3CBCVR41 are different cables.

Will the VW3A8106 cable kit for the Power Suite work on the ATV11 drive?

Issue:   Will the VW3A8106 cable kit for the Power Suite work on the ATV11 drive?
 
Product Line:   ATV11
 
Environment:  All
 
Cause:   VW3A8106 compatibility 
 
Resolution:   
Yes it will. The kits that shipped after December of 2002 include the VW3A11301 adapter. If the kit was shipped before that date then you must order the optional adapter.


 

ATV38 RFI Filter. Value of leakage current for size > 15 kW

Goals and Symptoms

ATV38
RFI Filter.
Value of leakage current for size > 15 kW

Causes and Fixes

It's the same filters like ATV68. The values are in VVD Catalog ( Dec 2002 ) page 2/236


Legacy KB System (APS) Data: RESL157278 V1.0, Originally authored by on , Last Edited by on
Related ranges: Altivar 38

What is the part number for a patch panel, 24 port, CAT 6, loaded?

The part number is RJ6/24PP.
 Some of the key features are:
  •  Universal colour coding for 568A and 568B standards
  • Removable rear cable management tray
  • Individual removable modular jacks
  • ACMA compliant
  • Dielectric Strength: 1,000 V RmS at 60hz for 1 minute
  • Current Rating: 1.5 A
  • Insulation Resistance: 10 mohm
  • Temperature Range: -10 to 60 deg C
  • Material: Phosphor bronze
  • Standard: AS/NZS 3080:2003, ISO/IEC 11801 2002 and ANSI/TIA/EIA-568-B 

 
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=RJ6/24PP 

What is the part number for a CAT 6 RJ45 Black shuttered 30 Mech?

The part number for a CAT 6 RJ45 Black shuttered 30 Mech is 30RJ45SMA6SH-BK.
Some of its key features are:
  • 30 Mechanism Shuttered
  • Fully compliant to AS/NZS 3080:2003, ISO/IEC 11801 2002 and ANSI/TIA/EIA-568-B Series connecting hardware standards
  • Backward compatible with category 5e products
  • Flexible Locking Tabs
  • IP22 Rated
  • -40 to 70 deg C Temperature range
  • Nickel plating
  • 0.7 - 1.6 mm Insulation diameter
  • Fire retardant UL 94v-0, Plastic
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30RJ45SMA6SH

What is the part number for a Cat6A shielded outlet?


The part number for a Cat 6A shielded modular socket to fit a 30 series plate is 30RJ45SM6AF. 

Some of the key features are:
  • Fully compliant to AS/NZS 3080:2003, ISO/IEC 11801 2002 and ANSI/TIA/EIA-568-C and ANSI/TIA/EIA-568-B.2-10 (draft) Connecting Hardware standards
  • Flexible locking tabs
  • Tool-less termination
  • -40 to 70 deg C Temperature range
  • Suits Clipsal wall plates
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30RJ45SM6AF







 

Can I get cat6A shielded mechs in red?

No, the Cat6A shielded connector mechanisms are made of metal and have no colour option.

Some of the key features are:
  • Fully compliant to AS/NZS 3080:2003, ISO/IEC 11801 2002 and ANSI/TIA/EIA-568-C and ANSI/TIA/EIA-568-B.2-10 (draft) Connecting Hardware standards
  • Flexible locking tabs
  • Tool-less termination
  • -40 to 70 deg C Temperature range
  • Suits Clipsal wall plates

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30RJ45SM6AF

 

Are replacement covers available fot T200 triple pole panel mount switch rated to 200A?

T200X was the part number of the replacement cover to suit T200. T200X is now discontinued and there is no alternate for T200X.
For further information on T200 please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=T200
User-added image

What are the A, B, C, D, E, F, G, H, and J ground fault ampere values for the Micrologic 6.0A, 6.0P, and 6.0H on the 1600A Masterpact breaker NW16H2?

Product Line:
Circuit Breakers

Environment:
Electrical Distribution Equipment.

Resolution:
For all 1200A sensors and greater they are 500A, 640A, 720A, 800A, 880A, 960A, 1040, 1120A, and 1200A respectively.

Has the 56SW432 changed design?

No, the design and or mechanism hasn't changed since December 2002. The mechanism was changed to a seven series mechanism.

What is the life cycle of the 30MBP?

The 30MBP has been tested to 12000 cycles.

What are the part numbers for the spring retainer clips for the PM200, 700, and 800 meters and contents of hardware kit?

Issue
A customer would like to order replacement spring retainer clips for the PowerLogic PM200, 700 or 800 series power meters. 

Product Line
PowerLogic PM200, PM700 and PM800 series Power Meters

Environment
PowerLogic PM200, PM700 and PM800 series Power Meters

Resolution
As a result of the similar dimensions and shape of the PM200, 700 and 800 series power meters, the mounting retainer spring clips can be used interchangeably. Each meter will require 2 retainer clips.

The retainer clips are sold as part of the PM800 hardware kit with the following part number: 63230-500-16.

Internal Part Numbers:

63230-503-11 Retainer Kit (Qty. 2)

63230-503-18 Retainer Kit w/2W terminator (Qty. 2 clips and 1 Terminator)

The PM800 series hardware kit contains all the following parts. The part numbers listed below are internal and as a result they cannot be ordered seperately.

1- Meter template for the cutout = Internal part # 63230-500-09 
1- KYCS Output/Input connector = Internal part # 63230-500-29 
1- RS-485 2-wire connector = Internal part # 63230-500-30 
1- Control Power Connector = Internal part # 63230-500-31 
2- Retainer spring clips for mounting = Internal part # 63230-500-38 
9- Blue Spade lug connectors 
1- 2-Wire RS-485 Terminator = MCT2W 
1- Voltage input connector = 63230-500-28

Wiring Recommendations for PM2 and PM7 Series Power Meters - AWG, Torque, and Strip Length Specifications

Please see attached PDF document for details.
Wiring Specifications PM2 & PM7.pdf

Keywords: Power Meter 200, Power Meter 700, PM200, PM700, PM750


Legacy KB System (APS) Data: RESL203833 V1.0, Originally authored by MaTh on 11/01/2010, Last Edited by MaTh on 11/01/2010
Related ranges: PM700 series, PM200 series

What is the part number for a Ftype in the prestige range?

Unfortunately this is not a standard preassembeled part. However, you can use a P30Z (Prestige Bezzel) with a 30PFM (30 F-Type mechanism).

Some of the key features for the P30Z are:

  • Mounting accessories
  • Switch mechanisms
  • Prestige panel
  • Suitable for mounting standard Clipsal 30 series mechanisms to the Prestige P2000 collection
  • Dimensions: 38 mm Length x 38 mm Width x 18 mm Depth
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=P30Z


Some of the key features for the 30PFM are:
 
  • Pay TV approved outlet rated to 3 GHz
  • Mating connections screw into the connector to provide minimum signal loss and optimum impedance matching to substantially reduce reflections and ghosting
  • TV antenna socket 75 Ohm
  • Suits PAY TV
  • IR pass through
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30PFM​


How can I correct error '2007 - Invalid Band collection Index' error in ProWORX 32?

To correct this error, delete the layout.acf file which is found in the \proworx\32 folder. It will be recreated when ProWORX 32 is launched.


Legacy KB System (APS) Data: RESL184052 V1.0, Originally authored by DaSo on 05/15/2007, Last Edited by DaSo on 05/15/2007
Related ranges: ProWORX

Why does ATS48 not operate when wired like the recommended diagram on page 74 of the June 2002 manual?

The user's manual recommended diagram on page 74 is incorrect for proper operation.  
On line 2 of the ladder diagram after fault relay R1A to R1C connection the coil that is labeled TR for trip relay should be a FR coil for fault relay.
Then should add a line after this that has a NC (normally closed ) FR ( fault relay ) contact in series with a TR ( trip relay ) coil.

This configuration would then allow proper operation of unit.

Micrologic Trip Units in a PowerLogic System Instruction Bulletin

Product Line
Micrologic Trip Unit

Environment
Communications

Resolution
For the ​Instruction Bulletin 63220-080-200/B1 from August 2002 "Using MICROLOGIC® Electronic Trip Units in a POWERLOGIC® System (includes Type A, Type P, and Type H trip units)" see attached document below.

Note: This document provides the following information:

  • adding MICROLOGIC electronic trip units to your POWERLOGIC© system
  • using alarms and events, control outputs, and device resets in SMS for MICROLOGIC electronic trip units
  • creating custom quantities and custom tables to view data in SMS from MICROLOGIC electronic trip units
NOTE: This document contains specific information about the Type A, Type P, and Type H MICROLOGIC electronic trip units only. 

What is the part number for a CAT 6 mechanism?

The part number for a Cat 6 modular socket is 30RJ45SMA6.

Some of the key features are:
  • 30 Mechanism non-shuttered
  • Fully compliant to AS/NZS 3080:2003, ISO/IEC 11801 Edition 2 2002 and ANSI/TIA/EIA-568-B Series connecting hardware standards
  • Backward compatible with category 5e products
  • UL 94V-0 Rated
  • Various colours for easier circuit identification
  • Can be used in multi-user teleco comunication outlets
  • Flexible locking tabs for easy removal from wall plates

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30RJ45SMA6
 

What is the part number for a cat 6 mech to suit patch panel?

The part number is RJ45SMA6-BK

Please click this link for further information
https://www.clipsal.com/Trade/Products/ProductDetail?catno=RJ45SMA6

Key Features

  • Keystone non-shuttered
  • Fully compliant to AS/NZS 3080:2003, ISO/IEC 11801 2002 and ANSI/TIA/EIA-568-B Series connecting hardware standards
  • Backward compatible with category 5e products
  • UL 94V-0 Rated
  • Various colours for easier circuit identification
  • Can Be Used In Multi-user teleco mmunication outlet Applications (MUTO) And Consolidation points (CP)
  • -40 to 70 deg C Temperature range
  • Nickel plating
  • 0.7 - 1.6 mm Insulation diameter
  • Fire retardant UL 94v-0, Plastic

User-added image
 

To what standards do the Cat6 patch leads (cords) comply to?

Clipsal Cat 6 patch leads are fully compliant to AS/NZS 3080:2003, ISO/IEC 11801 Edition 2 2002 and ANSI/TIA/EIA-568-B Series Connecting Hardware Standards.
Part numbers are as follows:
CATALOGUE NUMBER DESCRIPTION
RJ6/05PL (xx) Category 6 Modular Patch Cord, 0.5m
RJ6/10PL (xx) Category 6 Modular Patch Cord, 1m
RJ6/15PL (xx) Category 6 Modular Patch Cord, 1.5m
RJ6/20PL (xx) Category 6 Modular Patch Cord, 2m
RJ6/30PL (xx) Category 6 Modular Patch Cord, 3m
RJ6/50PL (xx) Category 6 Modular Patch Cord, 5m
(XX) for Colour: White (WE), Black (BK), Blue (BU), Yellow (YL), Red (RD), Green (GR) and Grey (GY)

Is there a CAT 6A RJ45 shielded 30 Mechanism?

Yes, the part number for a CAT 6A RJ45 shielded 30 Mechanismis is a 30RJ45SM6AF.

Some of the key features are:

  • Fully compliant to AS/NZS 3080:2003, ISO/IEC 11801 2002 and ANSI/TIA/EIA-568-C and ANSI/TIA/EIA-568-B.2-10 (draft) Connecting Hardware standards
  • Flexible locking tabs
  • Tool-less termination
  • -40 to 70 deg C Temperature range
  • Suits Clipsal wall plates
  • backward compatible with Category 5e and 6 products, allowing component mixing without degrading the network below the minimum component category
  • Flexible locking tabs allow for easy removal from wall plates
  • Designed to eliminate alien crosstalk (ANEXT)
  • 0.7 - 1.6 mm Insulation Diameter
For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=30RJ45SM6AF

 

STBAVO1250 Byte Reversal in a Profibus Island Fixed in Exec v2.02

Goals and Symptoms

If a Profibus master and STBNDP2212 island were power cycled simultaneously, when communication resumed, the output channel upper and lower bytes sent to an STBAVO1250 would occasionally be swapped. After the described power cycle was done, 3200 Hex sent to the Profibus island could result in 0032 Hex being written to an AVO output channel register. Another power cycle cleared the error and resulted in the bytes being written correctly.

Facts and Changes

No other output modules appeared to be affected. Powering the units separately did not appear to cause the problem to occur.

Causes and Fixes

The issue has been addressed with new executive software for the STBNDP2212. Those NIMs loaded with v2.02 executive software will not display the problem.
Production modules loaded with the exec are marked SV: 02.02 and PV:08.

The web accessed exec file name is ai_nim_ndp_02_02.bin.

The problem had been observed when a Siemens S7315-2DP w/2.00 firmware was used for the head. Other head configurations had not been observed to cause the problem. However, due to the intermittent nature of the problem, users were cautioned to not power cycle Profibus heads and associated STB islands at the same time.

This resolution replaces an earlier version that described the problem and indicated a fix was being investigated.


Legacy KB System (APS) Data: RESL172489 V3.0, Originally authored by on , Last Edited by on
Related ranges: Advantys STB

Sepam EcoFit offer

Schneider Electric offers a retrofit solution for converting Sepam 2000's to the new Sepam 1000+ relays.
ECOFIT S2000 Leaflet - SERED111087EN.pdfECOFIT S2000 Leaflet - SERED111087EN.pdfECOFIT SEPAM 2000 Customer Presentation Rev1a.pptECOFIT SEPAM 2000 Customer Presentation Rev1a.ppt

What is the part number of the cover to suit P2015 standard size Prestige single socket outlet?

P2002 is the part number of the cover to suit P2015 standard size Prestige single socket outlet.
For further information, please visit:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=P2002
https://www.clipsal.com/Trade/Products/ProductDetail?catno=P2015

User-added image
User-added image

What is the part number of the fire rated wall box to suit large format (size 116 x 116mm) P2000, Prestige plates?

157/2F is the part number of the fire rated wall box to suit large format P2000, Prestige plates. 157/2F is 2 Gang Metal Fire Rated Wall Box, with sliding nuts for accurate alignment of accessory, for masonry walls. Suits 1 hour and 2 hour fire rated applications. Dimensions are 94mm (L) x 97mm (W)x 47mm (D). Mounting centers are 84mm x 46mm.

 

What is the part number for a Prestige P2000, three speed fan controller mechanism?

Prestige P2000, three-speed fan controller mechanism can be put together using the below part numbers:
P30Z - Prestige Adaptor clip to suit 30 series mechanisms
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=P30Z


30CSFM - 30 Series Standard Range, Fan Speed Controller Mechanism 250V 75VA - 3 Speed
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30CSFM


P2031VF3CBKB (available only in white) - 3 speed fan controller knob only to suit Prestige 
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=P2031VF3CBKB

 

Is there a non metallic circuit breaker enclosure available for the Molded Case Circuit Breakers?

Issue:
Is there a non-metallic (ie. fiberglass, etc) breaker enclosure for MCCBs?

Product Line:
Circuit Breaker Enclosure

Environment:
Square D Breaker Enclosure

Resolution:
There are no circuit breaker enclosures available for molded case circuit breakers that is manufactured from a non metallic material. Only metal type enclosures are available.

What is part number for C2000 series 5 gang cover?

The part number for C2000 series 5 gang cover is a C2035C.

What is part number for 2 gang C2000 series vertical cover?

The part number for 2 gang C2000 series vertical cover is C2025VC.
Show More