Residual Current Circuit Breaker, 2 Pole, 20A, 10MA, Vertical

Catalogue Number: ML2031VRC10
RCD 2P 10MA 20A 240V VERT SW
RCD 2P 10MA 20A 240V VERT SW
RCD 2P 10MA 20A 240V VERT SW
RCD 2P 10MA 20A 240V VERT SW
RCD 2P 10MA 20A 240V VERT SW
RCD 2P 10MA 20A 240V VERT SW
RCD 2P 10MA 20A 240V VERT SW
RCD 2P 10MA 20A 240V VERT SW
RCD 2P 10MA 20A 240V VERT SW
RCD 2P 10MA 20A 240V VERT SW
RCD 2P 10MA 20A 240V VERT SW
RCD 2P 10MA 20A 240V VERT SW
Colour: White Electric
Colour: Per UOM Std.
  • Dark Blue 1 PCE
  • Red 1 PCE
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
  • Medilec
  • ML2000 Moulded Series
    • Product or component type
      residual current device
      Product brand
      Clipsal
      Poles description
      2P
      [In] rated current
      20 A
      Earth-leakage sensitivity
      10 mA
      Earth-leakage protection class
      class AC
      Network frequency
      50 Hz
      [Ue] rated operational voltage
      250 V AC
      Mounting mode
      flush mounting
      Size
      116 x 76 mm conforming to DIN 43880
      Number of gangs
      1 gang
      Standards
      AS/NZS 3190
      EU RoHS Directive
      Compliant
      Mercury free
      Yes
      RoHS exemption information
      Yes
      China RoHS Regulation
      Product out of China RoHS scope. Substance declaration for your information

      Frequently Asked Questions

      hide show

      What is the difference between the ML2031VRC10 and ML2031VRCD10?

      ML2031VRCD10 can be mounted vertically and horizontally whereas the ML2031VRC10 is vertical only.

      What is the difference between the ML2031VRC10 and ML2031VRCD10?

      ML2031VRCD10 can be mounted vertically and horizontally whereas the ML2031VRC10 is vertical only.

      What is the new code for ML2031VRC10

      new code is ML2031VRCD10

      Where should the twin brown wires be connected on 2031RC series?

      The 2031RC series consists of 2031RC30, 2031VRC30, 2031RC10, 2031VRC10, ML2031RC10 and ML2031VRC10.

      The twin brown wires power the Line Power Available LED. These wires must be connected into the Line Active and Neutral terminals with the incoming supply wires.
      For further information please refer to the attached installation instruction

      What is the difference between ML2031VRC10-RD and ML2031VRCD10-RD

      The buttons look different

      What is the difference between the ML2031RC10 and the ML2031RCD10?

      They have the exact same operating characteristics however the ML2031RCD10 was based on the PDL design where as the ML2031RC10 is based on the Clipsal 2000 Series.
      Some of the key features are:
      • 1 gang
      • Amber indicator marked supply power available
      • Red indicator marked line power available
      • In-built test facility
      • Uses the flexible Clipsal 2000 Series system
      • < 40 ms trip time
      • Horizontal Mount
      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=ML2031RC10


       

      Is the ML2031VRC10 double pole ?

      Yes, the ML2031VRC10 is 2 pole RCD

      Some of the key features are:
      • 1 gang
      • Amber indicator marked supply power available
      • Red indicator marked line power available
      • In-built test facility
      • < 40 ms trip time
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=ML2031VRC10.

      Is the 2031VRC10 an MCB/RCD or is it only an RCD?

      The 2031VRC10 is an RCD only
      For further information , visitl link below:-
      https://www.clipsal.com/Trade/search-results?q=2031VRC10
      User-added image
       

      What is the alternative for the PDL 691RCD10 in red

      If it is not in a hospital you could use a PDL 691RCD10 in white and order a red cover as a special.  For a hospital use a Clipsal ML2031VRC10 and Clipsal 2025RD together in a double surround.

      How do I wire my neon indicator in the ML2031VRC?

      The brown wires will be the active and neutral for the neon, these are non-polarity sensitive and go in between the line terminals.

      What is the indication on the Clipsal ML2025RC10

      It has a power available neon

      What is the part code for a Medilec twin switch socket 10A with 10mA RCD

       The part code is ML2025RC10
      Show More