TeSys LC1D contactor, 3 poles, power connections by EverLink, with cover, 40A to 65A
TeSys D 3P Everlink AC Contactor AC3 40A IEC
TeSys LC1D contactor, 3 poles, power connections by EverLink, with cover, 40A to 65A
TeSys D 3P Everlink AC Contactor AC3 40A IEC

TeSys D Contactor, 3P(3 NO), AC-3, <= 440V, 40A, 240VAC, 50/60 Hz Coil

Catalogue Number: LC1D40AU7
TeSys LC1D contactor, 3 poles, power connections by EverLink, with cover, 40A to 65A
TeSys D 3P Everlink AC Contactor AC3 40A IEC
TeSys LC1D contactor, 3 poles, power connections by EverLink, with cover, 40A to 65A
TeSys D 3P Everlink AC Contactor AC3 40A IEC
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
TeSys D
Range
TeSys
Product name
TeSys D
Product or component type
contactor
Device short name
LC1D
Contactor application
  • motor control
  • resistive load
    • Utilisation category
    • AC-3
    • AC-4
    • AC-1
      • Poles description
        3P
        Pole contact composition
        3 NO
        [Ue] rated operational voltage
      • power circuit: <= 690 V AC 25...400 Hz
      • power circuit: <= 300 V DC
        • [Ie] rated operational current
        • 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
        • 40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
          • Motor power kW
          • 18.5 kW at 380...400 V AC 50/60 Hz (AC-3)
          • 11 kW at 220...230 V AC 50/60 Hz (AC-3)
          • 22 kW at 415...440 V AC 50/60 Hz (AC-3)
          • 22 kW at 500 V AC 50/60 Hz (AC-3)
          • 30 kW at 660...690 V AC 50/60 Hz (AC-3)
          • 9 kW at 400 V AC 50/60 Hz (AC-4)
            • Motor power hp
            • 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
            • 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
            • 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors
            • 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors
            • 3 hp at 115 V AC 50/60 Hz for 1 phase motors
            • 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors
              • Control circuit type
                AC at 50/60 Hz
                [Uc] control circuit voltage
                240 V AC 50/60 Hz
                Auxiliary contact composition
                1 NO + 1 NC
                [Uimp] rated impulse withstand voltage
                6 kV conforming to IEC 60947
                Overvoltage category
                III
                [Ith] conventional free air thermal current
              • 10 A (at 60 °C) for signalling circuit
              • 60 A (at 60 °C) for power circuit
                • Irms rated making capacity
                • 140 A AC for signalling circuit conforming to IEC 60947-5-1
                • 250 A DC for signalling circuit conforming to IEC 60947-5-1
                • 800 A at 440 V for power circuit conforming to IEC 60947
                  • Rated breaking capacity
                    800 A at 440 V for power circuit conforming to IEC 60947
                    [Icw] rated short-time withstand current
                  • 320 A 40 °C - 10 s for power circuit
                  • 720 A 40 °C - 1 s for power circuit
                  • 72 A 40 °C - 10 min for power circuit
                  • 165 A 40 °C - 1 min for power circuit
                  • 100 A - 1 s for signalling circuit
                  • 120 A - 500 ms for signalling circuit
                  • 140 A - 100 ms for signalling circuit
                    • Associated fuse rating
                    • 10 A gG for signalling circuit conforming to IEC 60947-5-1
                    • 80 A gG at <= 690 V coordination type 1 for power circuit
                    • 80 A gG at <= 690 V coordination type 2 for power circuit
                      • Average impedance
                        1.5 mOhm - Ith 60 A 50 Hz for power circuit
                        [Ui] rated insulation voltage
                      • power circuit: 600 V CSA certified
                      • power circuit: 600 V UL certified
                      • signalling circuit: 690 V conforming to IEC 60947-1
                      • signalling circuit: 600 V CSA certified
                      • signalling circuit: 600 V UL certified
                      • power circuit: 690 V conforming to IEC 60947-4-1
                        • Electrical durability
                        • 1.4 Mcycles 60 A AC-1 at Ue <= 440 V
                        • 1.5 Mcycles 40 A AC-3 at Ue <= 440 V
                          • Power dissipation per pole
                          • 2.4 W AC-3
                          • 5.4 W AC-1
                            • Protective cover
                              with
                              Mounting support
                            • plate
                            • rail
                              • Standards
                              • CSA C22.2 No 14
                              • EN 60947-4-1
                              • EN 60947-5-1
                              • IEC 60947-4-1
                              • IEC 60947-5-1
                              • UL 508
                                • Product certifications
                                • CSA
                                • CCC
                                • UL
                                • GOST
                                  • Connections - terminals
                                  • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
                                  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
                                  • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
                                  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
                                  • control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
                                  • control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
                                  • power circuit: screw connection 1 cable(s) 1-35 mm²flexible without cable end
                                  • power circuit: screw connection 2 cable(s) 1-25 mm²flexible without cable end
                                  • power circuit: screw connection 1 cable(s) 1-35 mm²flexible with cable end
                                  • power circuit: screw connection 2 cable(s) 1-25 mm²flexible with cable end
                                  • power circuit: screw connection 1 cable(s) 1-35 mm²solid without cable end
                                  • power circuit: screw connection 2 cable(s) 1-25 mm²solid without cable end
                                    • Tightening torque
                                    • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
                                    • control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
                                    • power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25-35 mm² hexagonal screw head 4 mm
                                    • power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1-25 mm² hexagonal screw head 4 mm
                                      • Operating time
                                      • 4...19 ms opening
                                      • 12...26 ms closing
                                        • Safety reliability level
                                        • B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
                                        • B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
                                          • Mechanical durability
                                            6 Mcycles
                                            Maximum operating rate
                                            3600 cyc/h 60 °C
                                            Coil technology
                                            without built-in suppressor module
                                            Control circuit voltage limits
                                          • drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 °C)
                                          • operational: 0.8...1.1 Uc AC 50 Hz (at 60 °C)
                                          • operational: 0.85...1.1 Uc AC 60 Hz (at 60 °C)
                                            • Inrush power in VA
                                            • 140-140 VA 60 Hz cos phi 0.75 (at 20 °C)
                                            • 160-160 VA 50 Hz cos phi 0.75 (at 20 °C)
                                              • Hold-in power consumption in VA
                                              • 13-13 VA 60 Hz cos phi 0.3 (at 20 °C)
                                              • 15-15 VA 50 Hz cos phi 0.3 (at 20 °C)
                                                • Heat dissipation
                                                  4-5 W at 50/60 Hz
                                                  Auxiliary contacts type
                                                • type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
                                                • type mirror contact 1 NC conforming to IEC 60947-4-1
                                                  • Signalling circuit frequency
                                                    25...400 Hz
                                                    Minimum switching current
                                                    5 mA for signalling circuit
                                                    Minimum switching voltage
                                                    17 V for signalling circuit
                                                    Non-overlap time
                                                  • 1.5 ms on de-energisation between NC and NO contact
                                                  • 1.5 ms on energisation between NC and NO contact
                                                    • Insulation resistance
                                                      > 10 MOhm for signalling circuit
                                                      Contact compatibility
                                                      M2
                                                      Compatibility code
                                                      LC1D
                                                      IP degree of protection
                                                      IP20 front face conforming to IEC 60529
                                                      Protective treatment
                                                      TH conforming to IEC 60068-2-30
                                                      Pollution degree
                                                      3
                                                      Ambient air temperature for operation
                                                      -5-60 °C
                                                      Ambient air temperature for storage
                                                      -60-80 °C
                                                      Permissible ambient air temperature around the device
                                                      -40-70 °C at Uc
                                                      Operating altitude
                                                      3000 m without
                                                      Fire resistance
                                                      850 °C conforming to IEC 60695-2-1
                                                      Flame retardance
                                                      V1 conforming to UL 94
                                                      Mechanical robustness
                                                    • vibrations contactor open: 2 Gn, 5...300 Hz
                                                    • vibrations contactor closed: 4 Gn, 5...300 Hz
                                                    • shocks contactor closed: 15 Gn for 11 ms
                                                    • shocks contactor open: 10 Gn for 11 ms
                                                      • Height
                                                        122 mm
                                                        Width
                                                        55 mm
                                                        Depth
                                                        120 mm
                                                        Net weight
                                                        0.85 kg
                                                        Sustainable offer status
                                                        Green Premium product
                                                        REACh Regulation
                                                        Free of Substances of Very High Concern above the threshold
                                                        REACh free of SVHC
                                                        Yes
                                                        EU RoHS Directive
                                                        Compliant
                                                        Toxic heavy metal free
                                                        Yes
                                                        Mercury free
                                                        Yes
                                                        RoHS exemption information
                                                        Yes
                                                        China RoHS Regulation
                                                        X
                                                        Environmental Disclosure
                                                        ENVPEP1503009EN
                                                        Circularity Profile
                                                        ENVEOLI1503009EN
                                                        WEEE
                                                        The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                                                        Warranty
                                                        18 months

                                                        Documents & downloads

                                                        hide show
                                                        Filter items
                                                        • All

                                                        • CAD Files and Packs

                                                        • Product Brochures

                                                        • Technical Data Catalogues

                                                        • Installation Instruction

                                                        • Data Bulletin

                                                        • Product Environmental

                                                        • End of Life Manual

                                                        • Certificates (MSDS)

                                                        • Declaration of Conformity

                                                        Frequently Asked Questions

                                                        hide show

                                                        What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

                                                        Issue:
                                                        Identifying maximum voltage of an LC1D contactor

                                                        Product Line:
                                                        TeSys D Contactors

                                                        Environment:
                                                        IEC contactors and starters used in North America

                                                        Cause:
                                                        n/a

                                                        Resolution:
                                                        IThe maximum voltage per UL and CSA is 600VAC. 
                                                         

                                                        What is the replacement coil part number for the LC*D09 through LC*D32 and LC*DT20 through LC*DT40 TeSys contactors?

                                                        Issue:
                                                        Identifying replacement coils for tesys D non-reversing and reversing conactors

                                                        Product Line:
                                                        IEC Contactors and Starters

                                                        Environment:
                                                        Products sold and used in the United States

                                                        Cause:
                                                        Replacement coil is needed

                                                        Resolution:
                                                        DC replacement coils are not available.
                                                        AC Coils are 50/60 hertz for voltages as listed below:

                                                        Volts - Part Number
                                                        12 ____ LXD1J7
                                                        21 ____ LXD1Z7
                                                        24 ____ LXD1B7
                                                        32 ____ LXD1C7
                                                        36 ____ LXD1CC7
                                                        42 ____ LXD1D7
                                                        48 ____ LXD1E7
                                                        60 ____ LXD1EE7
                                                        100 ___ LXD1K7 ( never brought to North America )
                                                        110 ___ LXD1F7
                                                        115 ___ LXD1FE7
                                                        120 ___ LXD1G7
                                                        127 ___ LXD1FC7
                                                        200 ___ LXD1L7
                                                        208 ___ LXD1LE7
                                                        220 ___ LXD1M7
                                                        230 ___ LXD1P7
                                                        240 ___ LXD1U7
                                                        277 ___ LXD1W7
                                                        380 ___ LXD1Q7
                                                        400 ___ LXD1V7
                                                        415 ___ LXD1N7
                                                        440 ___ LXD1R7
                                                        480 ___ LXD1T7
                                                        575 ___ LXD1SC7
                                                        600 ___ LXD1X7
                                                        690 ___ LXD1Y7


                                                        Note: A contactor with an AC coil can be changed to a different AC voltage coil, IE you can take an LC1D09 with a 120VAC coil and put a 24VAC coil in it instead. An AC device cannot be switched to a DC coil, and a DC device cannot be switches to an AC coil. 

                                                        What is the altitude derating for a TeSys D-Line contactor?

                                                        Issue:​
                                                        What is the altitude derating for a TeSys D-Line contactor?

                                                        Product Line:
                                                        Digest 177 Section 18 : Contactors and Starters, IEC

                                                        Environment:
                                                        North American Products

                                                        Resolution:
                                                        The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

                                                        Voltage
                                                        3500m x 0.90
                                                        4000m x 0.80
                                                        4500m x 0.70
                                                        5000m x 0.60

                                                        Current
                                                        3500m x 0.92
                                                        4000m x 0.90
                                                        4500m x 0.88
                                                        5000m x 0.86

                                                        For example, an LC1D80 at 5000 meters:
                                                        - The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
                                                        - The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



                                                         

                                                        What is the power terminal lug data for the LC1D40, LC1D50, LC1D65, LP1D40, LP1D50, and LP1D65 contactor?

                                                        Issue:
                                                        Identifying power terminal lug data for the D2 style contactors

                                                        Product Line:
                                                        Tesys D line contactors

                                                        Environment:
                                                        Products sold and used in the United States

                                                        Cause:
                                                        Power terminal lug data required

                                                        Resolution:
                                                        For contactors with screw clamp terminals:
                                                        stranded cable w/o cable end : One #10-3 AWG or Two #10-4 AWG per terminal.
                                                        stranded cable w/cable end: One #10-4 AWG or Two #12-2 AWG per terminal.
                                                        solid cable: One #10-3 AWG or Two #10-6 AWG per terminal.

                                                        Where are the control coil terminals for TeSys LC1D09 to LC1D38 contactor?

                                                        Issue:
                                                        Determine the control coil terminal marking and location on LC1D09 to LC1D38 contactor

                                                        Product Line: 
                                                        Tesys D Contactors

                                                        Environment:
                                                        IEC contactors

                                                        Resolution:
                                                        The coil terminals are marked A1 and A2, you can see them on the front of the contactor on the white part (control section).  They are next to the auxiliary contact (13/14, 21/22) terminals.
                                                         

                                                        Do the Everlink reversing contactors come with electrical interlocking?

                                                        Issue:
                                                        Looking for electrical interlock kit for the LC1D65A Everlnk contactors

                                                        Product line:
                                                        Tesys D LC1D40A, LC1D50A, LC1D65A

                                                        Environment:
                                                        Everlink, all voltage codes

                                                        Cause:
                                                        Old D2 version offered an electrical interlock kit

                                                        Resolution:
                                                        The current Everlink version does not offer an electrical interlock kit.  The customer can wire electrical interlocking using the normally closed contacts provided on the contactor.

                                                        What is the power terminal lug data for the LC1D09, LC1DT20, LC1D12, and LC1DT25 contactor?

                                                        Issue:
                                                        Power terminal lug data required for the 9 and 12 amp rated Tesys D contactors

                                                        Product Line:
                                                        NEMA combination starters

                                                        Environment:
                                                        Products sold and used in the United States

                                                        Resolution:
                                                        For contactors with screw clamp terminals:
                                                        stranded cable w/o cable end : One or Two #18-10 AWG per terminal.
                                                        stranded cable w/cable end: One or Two #18-10 AWG per terminal.
                                                        solid cable: One or Two #18-8 AWG per terminal.

                                                        What is the code for the newer version of the LC1D40U7

                                                        That has been replaced with the Everlink LC1D40AU7

                                                        What is difference between LC1D50U7 and LC1D50AU7?

                                                        Following are the differences between the LC1D50U7 and the LC1D50AU7:

                                                        LC1D50AU7 has everlink terminals.
                                                        LC1D50AU7....is slightly larger case and accommodate LRD3XX overloads
                                                        Whereas
                                                        LC1D50U7 contactors accommodate LRD33XX overloads.

                                                         

                                                        Looking for a LC1D50A.. with a 240v coil

                                                         Part code is LC1D50AU7

                                                        Can I use a LA9D6569 reversing kit with LC1D40AU7 contactors

                                                        No, correct kit is a LAD9R3.

                                                        Can I still purchase a LE1D405N7 and a LE1D405U7 in NZ

                                                        These are obsolete no longer available
                                                        Show More