4 channel relay din learn

C-Bus DIN Rail Mounted, 4 Channel, 8 Modules, 250V, 10A, Relay

Catalogue Number: L5504RVFP
4 channel relay din learn
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Range of product
C-Bus
Range
C-Bus
Product brand
Clipsal
[Us] rated supply voltage
15...36 V DC
Network type
AC/DC
Device composition
socket-outlet
Connector type
screw terminals
Width
144 mm
Height
85 mm
Depth
65 mm
REACh Regulation
Free of Substances of Very High Concern above the threshold
REACh free of SVHC
Yes
EU RoHS Directive
Compliant
Toxic heavy metal free
Yes
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
 Pro-active China RoHS declaration (out of China RoHS legal scope)

Documents & downloads

hide show
Filter items
  • All

  • CAD Files and Packs

  • Product Brochures

  • Technical Data Catalogues

  • Technical Leaflet

  • Installation Instruction

  • Product Environmental

  • End of Life Manual

  • Operating Manuals

  • System User Guide

  • Specifications

  • Application Solutions

  • Certificates (MSDS)

  • Corporate Marketing

  • Software - Released

Frequently Asked Questions

hide show

What is the Maximum current which can be drawn through a single channel on a relay

L5504RVF, L5508RVF and L5512RVF are rated for 10A for either resistive, inductive or fluorescent loads

The L5504RVF20 is rated for 20A for either resistive, inductive or flourescent loads

 

What are the codes for 4 channel, 10A, CBus relays?

L5504RVF - DIN rail mounted 4 channel 10A relay with power supply
L5504RVFP - DIN rail mounted 4 channel 10A relay without CBus power supply

What is the code for a CBus 4 channel relay without power supply

 Part code L5504RVFP

What is the difference between L5508RVFP and L5508RVF?

L5508RVFP and L5508RVF are C-Bus DIN Rail Mounted Relay Units, 250V AC 10A 8 Channel, 12M modules wide. The only difference between the two is L5508RVFP does not come with C-Bus Power Supply and L5508RVF is with 200mA C-Bus internal Power Supply.
For further information, please visit:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=L5508RVFP
https://www.clipsal.com/Trade/Products/ProductDetail?catno=L5508RVF

User-added image
User-added image

What are the C-BUS Relay part numbers?

You have several options for relays, Catalogue numbers and information below.

L5504RVF, L5504RVFP** - 4 Channel voltage free relay - 10amps per channel
L5508RVF, L5508RVFP** - 8 Channel voltage free relay - 10amps per channel
L5512RVF, L5512RVFP** - 12 Channel voltage free relay - 10amps per channel

L5504RVF20, L5504RVF20P** - 4 Channel voltage free relay - 20amps per channel

L5508RELVP - 8 Channel Extra Low Voltage Relay

5101R - Single and Two Channel 250v AC 10amp relay
5102RVF - Single and Two Channel 250v AC 10amp Voltage Free Relay

** Any part number that has a 'P' after the part number for Din Rail mount units does NOT include a C-Bus 200ma Power Supply.

What is the Load Rate of C-Bus 4 Channel Voltage Free Relay (L5504RVF or L5504RVFP)?

C-Bus 4 Channel Voltage Free Relay (L5504RVF or L5504RVFP) Load Rate are Up to 10A for Resistive, Inductive and Fluorescent, Up to 2A for Motor (refer to its Installation Instruction Section 4.0 Compatible Loads, Page 3) 

 

Does the L5504RVF have it's own power supply?

Yes it has a 200mA power supply..
For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=L5504RVF
User-added image
 

What is the Load Rate of C-Bus 8 Channel Voltage Free Relay (L5508RVF or L5508RVFP)?

C-Bus 8 Channel Voltage Free Relay (L5508RVF or L5508RVFP) Load Rate are Up to 10A for Resistive, Inductive and Fluorescent, Up to 2A for Motor (refer to its Installation Instruction Section 4.0 Compatible Loads, Page 3) 

 

What is the part code for 8 channel relay with power supply for CBUS

 The part code is L5508RVF

What is the replacement for 5101R,1 Channel C-Bus Relay 250V AC 10A inductive load?

Unfortunately we do not have a direct replacement for 5101R. L5504RVFP would be an alternate.
 

Key Features

  • 220 - 240 V AC supply voltage
  • 47 - 53 Hz and 57 - 63 Hz supply frequency
  • Single phase
  • Voltage free, magnetically latched contact type
  • Greater than 60,000 switching operations
  • Compatible with resistive, inductive, incandescent and fluorescent loads up to 10 A
  • 2 x 1.5 mm² or 1 x 2.5 mm² terminals
  • 0˚C - 45˚C operating temperature
  • 10 - 95% RH, humidity range
  • 8 DIN modules
  • DIN mounted
  • 2 x RJ45 sockets connection

For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=L5504RVFP

What is the current rating per channel for an L5504D2UP

The current rating per channel is 2.5A

What is the CBUS shutter relay

 Part code is L5501RBCP

What is the code for a CBus curtain module

 It is L5501RBCP

What is part no for power supply to suit L5504D2UP

Part no 5500PS
for  more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=5500PS

User-added image

What is the part code for the C-Bus Single Channel Shutter Relay for Blinds/curtains?

The part number is L5501RBCP

What is the part number for a 12 channel relay with no power supply?

The part number for a 12 channel relay with no power supply is a L5512RVFP.
Some of the key features are:
  • 220 - 240 V AC supply voltage
  • 47 - 53 Hz and 57 - 63 Hz supply frequency
  • Single phase
  • Voltage free, magnetically latched contact type
  • Greater than 60,000 switching operations
  • Compatible with resistive, inductive, incandescent and fluorescent loads up to 10 A
  • 2 x 1.5 mmsq or 1 x 2.5 mmsq terminals
  • 0 - 45 deg C operating temperature
  • 10 - 95% RH, humidity range
  • 12 DIN modules
  • DIN mounted
  • 2 x RJ45 sockets connection
For further information please visit Clipsal - L5512RVFP - 12 Channel Relay, Voltage Free, Without Power Supply


 

What is the part number of the wall mounting enclosure to suit L5501RBCP 1 channel C-Bus Blind/Curtain/Shutter relay?

5501RE is the part number of the wall mounting enclosure to suit  L5501RBCP 1 channel C-Bus Blind/Curtain/Shutter relay.
For further information, please visit
https://www.clipsal.com/Trade/Products/ProductDetail?catno=5501RE
User-added image
 

How do I determine if a fan is suitable to be used with the C-Bus fan relay unit

Any fan which is switched via a 3 wire capacitor (low, medium, common) will be acceptable

What is the part number for a Cbus Universal Dimmer ?

The part nos is

L5504D2U  > this has inbuilt power supply
L5504D2UP > this has NO inbuilt power supply

This is the link to the webpage https://www.clipsal.com/Trade/Products/ProductDetail?catno=L5504D2U
https://www.clipsal.com/Trade/Products/ProductDetail?catno=L5504D2UP

User-added image
 

Can you have more than one fan controlled from a DLT?

You cannot natively control more than one fan. However implemention of multiple fans can be achieved through the use of logic, please contact Technical Support for a logic example.

Any logic examples are provided as is and are not able to be supported.

What is required for a Fan to be compatible with C-Bus?

For a fan to be compatible with C-Bus, it will require a 3 wire capacitor built for low and medium speeds.

This capacitor can then be wired into a L5501RFCP which will act on behalf of the rotary dial.

From there, a C-Bus switch can then be programmed to step through the speeds.

What is the Load Rate of C-Bus 12 Channel Voltage Free Relay (L5512RVF or L5512RVFP)?

C-Bus 12 Channel Voltage Free Relay (L5512RVF or L5512RVFP) Load Rate are Up to 10A for Resistive, Inductive and Fluorescent load, Up to 2A for Motor (refer to its Installation Instruction Section 4.0 Compatible Loads, Page 3) 

 

What are the power limitations on a shutter relay L5501RBCP?

The power limitations to the shutter relay L5501RBCP are a maximum load output of 24V DC, 24-240V AC and a maximum motor load of 2A.

Some of the key features for the L5501RBCP are:
  • DIN rail mounted, 2M wide
  • AC input impedance 80 kOhm at 1 kHz
  • Electrical isolation 3.75 kV RMS from C-Bus to mains
  • Maximum units per network 80
  • Load current rating 2 A (motor load)
  • Load voltage rating 24 V DC, 24 - 240 V AC
  • Warm up time 5 s
  • Network clock software selectable
  • Network burden software selectable
  • Class II switch
  • 4 kV rated impulse withstand voltage
  • 0 - 45 deg C operating temperature
  • 10 - 95% RH operating humidity
  • Mains terminals Accommodates 2 x 1.5 mmsq or 1 x 2.5 mmsq (2 x 15 AWG or 1 x 13 AWG)
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=L5501RBCP
 

 

What is part number for 0-10v C BUS DIMMER?

Part number is L5504AMP.

Why can't I purchase Schneider Electric US Lighting Control products any more?

Issue:
As of March 1, 2015 all US Lighting Control products (EXCEPT Powerlink and MVP panels) will enter their obsolescence phase and will no longer be purchasable for new orders. Management of the Prosumer Business has made a strategic decision to stop the Lighting Control initiative and concentrate our effort in new businesses with higher growth potential – Connected Home, Building Control in small buildings, and Electric Vehicle solutions.

Product Line:
All US Lighting Control product except Powerlink and MVP panels are affected. CBus, Occupancy Sensors, Low Voltage Switches, Relay Panels, Emergency Lighting Control Panels, Schneider Electric branded Current Limiting Panels, and Architectural Dimming Panels.

Environment:
US Lighting Control products

Cause:
Management of the Prosumer Business has made a strategic decision to stop the Lighting Control initiatives.

Resolution:
See cross reference sheet attached for available completive cross references.
 

What are the individual preset levels or percentages for Blind Shutter Relays?

Depending on the scenario they are being used in, you can have three options based on 1, 2 or 3 button control

1 Button Control:
98% - Shutter Toggle Open/Close

2 Button Control:
1% - Close Toggle/Stop
99% - Open Toggle/Stop

3 Button Control:
0% - Close
100% - Open
2% - Stop

If you find that the opposite of what is expected to happen is happening, please confirm the polarity of the wiring

What is the power output limitations of the L5501RFCP C-bus Sweep fan control?

The fan load rating must not exceed 1.5Amps.
The L5501RFCP C-Bus Ceiling Sweep Fan Controller unit is a DIN rail mounted C-Bus output device that provides speed control for a ceiling sweep fan. The Fan Controller uses multiple relays and a dual capacitor block for speed selection.
Some of its key features are:
  • C-Bus current requirement 18 mA, powered from C-Bus network, does not provide power for the C-Bus network
  • Maximum units per network 100
  • Network clock software selectable
  • Network burden Software selectable when Unit Address is 001
  • AC input impedance 100 kOhm at 1 k Hz
  • Warm-up time 10 s
  • Electrical isolation 3.75 kV from C-Bus to mains
  • Input voltage for fan motor 100 V AC to 240 V AC; input circuit must have a suitable circuit breaker
  • Fan load rating 1.5 A
  • Switch duty type (S1) Continuous duty. Line and neutral are switched. Fan motor and neutral are switched
  • Speed control Capacitive; capacitor block supplied by fan manufacturer for Low and Medium speeds. High speed uses direct on-line (no capacitor in the circuit). Three unique fan speeds Low, Med and Hi and Off
  • Connectors C-Bus: 2 x RJ-45
  • Capacitor block: 3 x push button for one 1.5 mm²
  • Fan: 2 x screw type for one 1.5 mm² wire
  • Input Power: 2 x screw type for up to two 1.5 mm² Indicators Unit, C-Bus, 3 x Fan speed
  • Control Local override pushbutton, not illuminated
  • Class of switch Class II
  • Rated impulse withstand voltage 4 kV
  • Proof tracking index (PTI) 175
  • Pollution degree 2
  • Glow wire test (GWIT) Level 3, 850° C
  • Mounting type DIN rail, or wall or ceiling space mounting in the optional plastic enclosure; For indoor use only
  • Operating temperature 0° to 65° C
  • Humidity 10 to 95% RH, non condensing
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=L5501RFCP
 

C-BUS - Can I open/close all shutters but still have individual control?

Yes you can, if you have for example 5 shutter relays all with separate group address for individual control and would like a master switch to open or close all then try the following:

On a device supporting scenes, create a close scene with all of those shutter relay groups set to 0%, under the Trigger Control tab create a Trigger Group with the action selector set to 0.
Now duplicate that scene and set the groups to 100%, under the Trigger Control select the same Trigger Group but now set the Action selector to 255.

On a key input (switch) change to the secondary application and select the Trigger Group with function on/off.

When pressed this will send the 255 to trigger one scene and when pressed off will send the 0 level to trigger the alternate scene.

 

Can C-Bus operate 0-10V light fittings

Yes, it requires a L5504AMP, and must be used in conjunction with a C-Bus system and can dim 0-10V or 1-10V ballasts.

Output Rating - Sinking: 15mA at Vout = 0V, 8mA at Vout = 10V, i.e. I = 15-(0.7*Vout)mA