iC60N RCBO 1P+N 6A…45A 30/100mA with overcurrent protection

Acti9 iC60N Earth Leakage Circuit Breaker, 1P + N, C Curve, 40A, 30 mA, 240V

Catalogue Number: A9D61840
iC60N RCBO 1P+N 6A…45A 30/100mA with overcurrent protection
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Circuit breaker application
distribution
Range
Acti 9
Product name
Acti 9 iC60 RCBO
Product or component type
residual current breaker with overcurrent protection (RCBO)
Device short name
iC60N RCBO
Poles description
1P + Ns
[In] rated current
40 A at 50 °C
Earthing system
TN
Curve code
C
Earth-leakage sensitivity
30 mA
Breaking capacity
6000 A Icn at 240 V AC 50/60 Hz
Neutral position
left
Number of protected poles
1
Device location in system
outgoer
Network type
AC
Network frequency
50 Hz
[Ue] rated operational voltage
240 V AC 50/60 Hz
Trip unit technology
thermal-magnetic
Breaking capacity code
N
Residual current tripping technology
voltage dependent
Earth-leakage protection time delay
instantaneous
Earth-leakage protection class
type A
[Icw] rated short-time withstand current
Icw: 250 A during 8/20 µs impulse withstand
[Ics] rated service breaking capacity
6000 A at 240 V AC 50/60 Hz
Limitation class
3
[Ui] rated insulation voltage
400 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
4 kV
Surge current
250 A
Suitability for isolation
yes
Contact position indicator
yes
Control type
toggle
Local signalling
ON/OFF indication
Mounting mode
clip-on
Mounting support
DIN rail
Comb busbar and distribution block compatibility
NO
9 mm pitches
2
Height
110 mm
Width
18 mm
Depth
77.5 mm
Net weight
205 g
Mechanical durability
20000 cycles
Electrical durability
5000 cycles
Provision for padlocking
padlockable with padlock Ø 4 mm
Locking options description
ON/OFF locking facilities
Connections - terminals
  • screw clamp terminal (top) 1-25 mm² rigid without cable end
  • screw clamp terminal (top) 1-16 mm² flexible
  • screw clamp terminal (bottom) 1-16 mm² rigid without cable end
  • screw clamp terminal (bottom) 1-10 mm² flexible
    • Wire stripping length
    • power circuit: 13 mm for bottom connection
    • power circuit: 14 mm for top connection
      • Tightening torque
      • power circuit: 3.5-3.5 N.m top
      • power circuit: 2-2 N.m bottom
        • Earth-leakage protection
          integrated
          Standards
        • IEC 61009-1
        • IEC 61009-2-2
        • AS/NZS 61009.1
          • IP degree of protection
          • IP20
          • IP40 (modular enclosure)
            • Tropicalisation
              2
              Relative humidity
              95-95 % at 55-55 °C
              Ambient air temperature for operation
              -15-60 °C
              Ambient air temperature for storage
              -40-85 °C
              Sustainable offer status
              Green Premium product
              REACh Regulation
              Free of Substances of Very High Concern above the threshold
              EU RoHS Directive
              Compliant
              Mercury free
              Yes
              RoHS exemption information
              Yes
              China RoHS Regulation
              Product out of China RoHS scope. Substance declaration for your information
              Environmental Disclosure
              ENVPEP121008EN
              Circularity Profile
              ENVEOLI121005EN

              Documents & downloads

              hide show
              Filter items
              • All

              • Product Brochures

              • CAD Files and Packs

              • Installation Instruction

              • End of Life Manual

              • Product Environmental

              • Certificates (MSDS)

              • Declaration of Conformity

              Frequently Asked Questions

              hide show

              What is the replacement part for a 26896 RCB?

              The replacement part is a A9D61820.
              A9D11220 is best solution
              A9D11820 is an alternative 1 pole wide but no Neutral switching
              A9D61820 is an alternative 1 pole wide but no Neutral switching and only 6kA
               

              Does the A9D61816 RCBO have a neutral tail?

              Yes the A9D61816 and all that range have a neutral tail and also an Earth reference point.

              Does the A9D61816 RCBO have a neutral tail?

              Yes, the A9D61816 and all that range have a neutral tail and also an Earth reference point
              for more information see data sheet https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=a9d61816
              User-added image

              What is the part number for a 45amp chassis style RCD/MCB combo C/B?

              The part number for a 45amp chassis style RCD/MCB combo C/B is - 6kA - A9D61845 , 10kA - A9D11845
              For further information, visit the link below:-
              https://www.schneider-electric.com.au/en/search/A9D61845
              https://www.schneider-electric.com.au/en/search/A9D11845
              User-added image
              User-added image

              What is the part number for an A9D11810 but in "D" curve?

              need to build up with "D" curve circuit breaker A9F55110 and vigi unit A9V02663
              for more details see ....... https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9F55110
              and ............... https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9V02663
              User-added image    User-added image

              What is the replacement code for a Merlin Gerin 23332 ?.

              The current equivalent is the A9R91440

              What is kA rating for A9R91440 ?

              The A9R91440 is Rated 10kA

               

              What is the replacement for the Merlin Gerin 23332?

              A9R91440

              Old Merlin Gerin Code 23382 4p 40amp 30ma RCCB is now ?

              Code now is A9R51440

              What do I need to put together a single phase 30A 56 Series RCD

              Use 56CB4 + A9R51240 40amp RCCB

              What is the code of the Domae version of a 23358 40A 2p RCCB?

              It is a DOM16695

              Is the Acti 9 range of RCCB 120v ac rated?

              All Acti9 RCCB's are rated 230-240v AC only

              What is the alternative to the 4RCBE210/30?

              Within the Schneider Electric range, the alternative for the 4RCBE210/30 is A9D11210

              What is the difference between A9D32620 and A9D33620 RCBO Acti 9 devices?

               
               

              A9D33620 = SI (Super Immunised)
              A9D32620 = Type A (AC or pulsating DC)

              Type A RCBO = Tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising.
              Type Si RCBO = With all the features of a Type A device, “Si” type Super Immunised earth leakage protection range has been specially developed to be used with loads or in environments causing disturbances. Examples are lightning or switching surges, harmonics generated by increasing number of loads and constant load leakage current from electronic ballasts, speed drives, computers, etc. The Si increases safety and allows improved continuity of supply.
               

              What items come with the KITWALLBOX7?

              A9Z51240 = Type B single phase RCCD
              A9F54240 = 2 pole, 40A, Curve MCB
              A9A26969 = Under voltage release

              What is the part code for a 3 pole din rail mount main switch

               What curent rating ?
              The part code is 3 pole 40amp mains Isolating switch is A9S66340 or Domae DCK12646 63amp 3 pole