iC60H RCBO 1P+N 6A…45A 30/100mA with overcurrent protection

Acti 9 iC60H Earth Leakage Circuit Breaker, 1P + N, C Curve, 16A, 100Ma, 240V

Catalogue Number: A9D12816
iC60H RCBO 1P+N 6A…45A 30/100mA with overcurrent protection
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Circuit breaker application
distribution
Range
Acti 9
Range of product
Acti 9
Product name
Acti 9 iC60 RCBO
Product or component type
residual current breaker with overcurrent protection (RCBO)
Device short name
iC60H RCBO
Poles description
1P + N
[In] rated current
16 A at 50 °C
Earthing system
TN
Curve code
C
Earth-leakage sensitivity
100 mA
Breaking capacity
10000 A Icn at 240 V AC 50/60 Hz
Neutral position
left
Number of protected poles
1
Device location in system
outgoer
Network type
AC
Network frequency
50 Hz
[Ue] rated operational voltage
240 V AC 50/60 Hz
Trip unit technology
thermal-magnetic
Breaking capacity code
H
Residual current tripping technology
voltage dependent
Earth-leakage protection time delay
instantaneous
Earth-leakage protection class
type A
[Icw] rated short-time withstand current
Icw: 250 A during 8/20 µs impulse withstand
[Ics] rated service breaking capacity
7500 A at 240 V AC 50/60 Hz
Limitation class
3
[Ui] rated insulation voltage
400 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
4 kV
Surge current
250 A
Suitability for isolation
yes
Contact position indicator
yes
Control type
toggle
Local signalling
ON/OFF indication
Mounting mode
clip-on
Mounting support
DIN rail
Comb busbar and distribution block compatibility
NO
9 mm pitches
2
Height
110 mm
Width
18 mm
Depth
77.5 mm
Net weight
205 g
Mechanical durability
20000 cycles
Electrical durability
5000 cycles
Provision for padlocking
padlockable with padlock Ø 4 mm
Locking options description
ON/OFF locking facilities
Connections - terminals
  • screw clamp terminal (top) 1-25 mm² rigid without cable end
  • screw clamp terminal (top) 1-16 mm² flexible
  • screw clamp terminal (bottom) 1-16 mm² rigid without cable end
  • screw clamp terminal (bottom) 1-10 mm² flexible
    • Wire stripping length
    • power circuit: 13 mm for bottom connection
    • power circuit: 14 mm for top connection
      • Tightening torque
      • power circuit: 3.5-3.5 N.m top
      • power circuit: 2-2 N.m bottom
        • Earth-leakage protection
          integrated
          Standards
        • BS EN 61009-1
        • AS/NZS 61009.1
        • IEC 61009-1
        • IEC 61009-2-2
          • IP degree of protection
            IP20
            Tropicalisation
            2
            Relative humidity
            95-95 % at 55-55 °C
            Ambient air temperature for operation
            -15-60 °C
            Ambient air temperature for storage
            -40-85 °C
            Sustainable offer status
            Green Premium product
            REACh Regulation
            Free of Substances of Very High Concern above the threshold
            EU RoHS Directive
            Compliant
            Mercury free
            Yes
            RoHS exemption information
            Yes
            China RoHS Regulation
            Product out of China RoHS scope. Substance declaration for your information
            Environmental Disclosure
            ENVPEP121008EN
            Circularity Profile
            ENVEOLI121005EN
            WEEE
            The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins

            Documents & downloads

            hide show
            Filter items
            • All

            • Product Brochures

            • CAD Files and Packs

            • Technical Data Catalogues

            • Installation Instruction

            • End of Life Manual

            • Product Environmental

            • Certificates (MSDS)

            • Declaration of Conformity

            Frequently Asked Questions

            hide show

            What is the part number for 2 pole 16amp RCBO 2 modules wide?

            The part name is A9D11216

            Does the A9D61816 RCBO have a neutral tail?

            Yes the A9D61816 and all that range have a neutral tail and also an Earth reference point.

            Does the A9D61816 RCBO have a neutral tail?

            Yes, the A9D61816 and all that range have a neutral tail and also an Earth reference point
            for more information see data sheet https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=a9d61816
            User-added image

            What is the difference between A9D32620 and A9D33620 RCBO Acti 9 devices?

             
             

            A9D33620 = SI (Super Immunised)
            A9D32620 = Type A (AC or pulsating DC)

            Type A RCBO = Tripping is ensured for residual sinusoidal alternating currents and residual pulsating direct currents, whether suddenly applied or slowly rising.
            Type Si RCBO = With all the features of a Type A device, “Si” type Super Immunised earth leakage protection range has been specially developed to be used with loads or in environments causing disturbances. Examples are lightning or switching surges, harmonics generated by increasing number of loads and constant load leakage current from electronic ballasts, speed drives, computers, etc. The Si increases safety and allows improved continuity of supply.
             

            What is the part number for an A9D11810 but in "D" curve?

            need to build up with "D" curve circuit breaker A9F55110 and vigi unit A9V02663
            for more details see ....... https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9F55110
            and ............... https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=A9V02663
            User-added image    User-added image

            What is the alternative to the 4RCBE210/30?

            Within the Schneider Electric range, the alternative for the 4RCBE210/30 is A9D11210

            What is the replacement part for a 26896 RCB?

            The replacement part is a A9D61820.
            A9D11220 is best solution
            A9D11820 is an alternative 1 pole wide but no Neutral switching
            A9D61820 is an alternative 1 pole wide but no Neutral switching and only 6kA
             

            Where can I download the latest version of ION Setup software?

            Issue
            Latest version of ION Setup software Installer is required.

            Product Line
            ION Setup 3.1.x

            Environment
            Software Installation Files

            Resolution
            The latest version of ION Setup is v3.1.19072.01 published on March 13, 2019.

            The latest version can be downloaded using the link below:
            ION Setup Software

            The ION Setup Software, User Guide, and Device Configuration Guide can also be obtained by visiting link below
            (Note: The latest version of ION Setup software may not be up-to-date from the link below):
            ION Setup Software and Documents

            For ION Setup 3.0 User Guide and Device Configuration Guide, refer to article FA346479

            For ION Setup revision History and Features & Fixes, refer to article FA222043

            ION Setup is only supported on Windows Vista and newer.1

            Note that for the best compatibilityy, we strongly recommend that users run ION Setup on windows versions that are officially supported by Microsoft.
            Kindly refer to the Microsoft link below for end of support information:

            https://support.microsoft.com/en-us/lifecycle/search

            Which RCBO can ben used in hospitals?

            The only range of RCBO's that can be used in hospitals are:
            Electronic Models -
            4RCBE206/10 4RCBE206/10S
            4RCBE210/10  4RCBE210/10S
            4RCBE220/10 4RCBE220/10S
            4RCBE225/10 4RCBE225/10S
            4RCBE232/10 4RCBE232/10S
            4RCBE240/10  

            Unfortunately you cannot use Schneider A9D108** range as it doesnt switch the neutral.


            For further information see attached PDF or visit https://www.clipsal.com/Trade/search-results?q=4RCBE%20range&t=documentation