connector cable 1screw

500 Series Cable Connectors, 1 Screw, Extended, Suits up to 3 x 6mm² Cables

Catalogue Number: 563L1
connector cable 1screw
Colour:
Colour: Per UOM Std.
  • 1 PCE

Specifications

hide show
Product brand
Clipsal
Provided equipment
1 x screw
Cable cross section
6-6 mm² fine stranded without cable end sleeve
Connector type
screw terminals
EU RoHS Directive
Compliant
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
Product out of China RoHS scope. Substance declaration for your information

Frequently Asked Questions

hide show

Is the 563L2 still available?

Yes, the 563L2 is still part of our range.

Some of the key features are:
  • 3 cables
  • Grey insulated
  • Extended

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=563L2





 

Is 56L1 available in Black?

Part no not available in Black closest color is WW. 

What colour is the PDL 56L1 (1 gang (28mm) enclosure lid) available in?

The 56L1 is available in chemical Resistant White (RW), Clear (CL), chemical Resistant Orange (RW) and Grey (GY).
Code example (56L1 in Grey): PDL 56L1LEGY

What is the replacement for 563B/1, 563/2, 563G1 and 563G2?

563B/100 replaces 563/1, 563/2, 563G1 and 563G2.

Some of the key features are:
  • Single screw connectors will suit either a No. 2 Philips Drive or a No. 1 Square Drive screwdriver
  • Connectors are fully compliant with AS/NZS3000:2007 as per clause (d) from Sub-section 2.9.4. for active, neutral and earth connections
  • Connectors will be packed only in boxes of 100 for better convenience and transportation
  • Terminal connectors will now be square wrapper design, ensuring reliable connection
Further information can be found at https://www.clipsal.com/Trade/Products/ProductDetail?catno=563B/100

Can you get the gasket for a 56L1 as a seperate/ spare part?

Yes the part number is 56G1

What is the part code for a suspended waterproof data outlet

 The part codes are: 56PE2/25 + 56L1 + 56MO500/1 + 619MD

What are the connectors in the 554J4?

The 554J4 has 3 x 563G1 and 1 x 563G2.

For more information, please refer to the link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=554J4




 

Is part number 56L1 available in colour WW?

Yes it is available in WW.

for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=56L1

User-added image

What is the operating temperature of the 563/1 and the 563/2 1 and 2 screw bluepoints?

Our connectors are made of Polypropylene (which is a flame retardant material) according to the supplier this material can hold up top +-165C.
Although I will not recommend more than room temperature + 40C.
Keep in mind cables will not stand such temperature anyway as they normally rated between 75C to 90C

Some of the key features are:
  • Cable Connectors
  • Single or double screw
  • Clear insulated
  • Suits up to 2 x 6mm² cables


 

Can the 563/1 connector be used for an earth connection?


No, unfortunately the 563/1 screw connectors are not suitable for an earth connector as the screw is only 67% of the tunnel.
Alternatively you are able to use any of our two screw connectors as they do apply with current rules and regulations of AS3000.
 


I.e. 563/2


Key features:

 

  • 2x 6mm cables
  • Clear insulation
  • 2 Screw

For further information please visit  https://www.clipsal.com/Trade/Products/ProductDetail?catno=563/2 


 


 

 


 

Do you do a 1 gang version of a KPP1?

No just use a 56L1 on the bottom

Part No.: KPP1

What comes with a PDL 56FA1

The PDL 56FA1 comes with Mounting flange, Foam sealing gasket, mounting plate, and necessary screws

What are the Commercial and Government Entity (CAGE) codes for Schneider Electric (US only)?

The CAGE codes for Schneider Electric/SQUARE D are listed below:
CAGE Code Company Address
04429 SQUARE D CO LEEDS MFG PLANT 940 MOORE ST NE LEEDS, AL 35094
05684 SQUARE D CO MIDDLETOWN MFG PLANT 1500 S UNIVERSITY BLVD MIDDLETOWN, OH 45044
07442 SQUARE D CO DALLAS ASSEMBLY PLANT 1111 REGAL ROW DALLAS, TX 7524
12670 SQUARE D COELECTROMAGNETIC INDUSTRIES DIV 1410 DONALDSON PIKE B-5 NASHVILLE, TN 37217
14280 SQUARE D CO LEXINGTON MFG PLANT 1601 MERCER RD LEXINGTON, KY 40511
14799 SQUARE D CO CHICAGO ASSEMBLY PLANT 9522 W WINONA SCHILLER PARK, IL 60176
19804 SQUARE D CO GRAND BAY OF BRECKSVILLE 6995 S EDGERTON RD SUITE 100 BRECKSVILLE, OH 44141
2E203 SQUARE D CO 810 GLEN EAGLE CT SUITE 100 BALTIMORE, MD 21286
4T466 SQUARE D CO 1010 AIRPARK CENTER DR NASHVILLE, TN 37217
51917 SQUARE D CO ASHEVILLE MFG PLANT 128 BINGHAM RD ASHEVILLE, NC 28806
51918 SQUARE D CO AUTOMATION AND CONTROL BUSINESS RALEIGH, NC 27611
51920 SQUARE D CO COLUMBIA MFG PLANT SUMTER HWY 76 AND 378 COLUMBIA, SC 29209
55947 SQUARE D CO SORGEL MFG PLANT 4065 N RICHARDS ST MILWAUKEE, WI 53212
56158 SQUARE D CO OSHKOSH MFG PLANT 3300 MEDALIST DR OSHKOSH, WI 54901
56302 SQUARE D CO CEDAR RAPIDS MFG PLANT 3700 6TH ST SW CEDAR RAPIDS, IA 52406
56303 SQUARE D CO 1717 CENTER PARK RD LINCOLN, NE 68512
56304 SQUARE D CO OXFORD MFG PLANT 5735 COLLEGE CORNER RD OXFORD, OH 45056
56365 SQUARE D CO CORPORATE OFFICES 1415 S ROSELLE RD PALATINE, IL 60067
63637 SQUARE D CO MISSOURI MFG PLANT 4800 PARIS RD COLUMBIA, MO 65202
63831 SQUARE D CO HUNTINGTON PLANT 6 COMMERCIAL RD HUNTINGTON, IN 46750
70745 SQUARE D CO SENECA PLANT 1990 SANDIFER BLVD SENECA, SC 29678
88434 SQUARE D CO 13191 CROSSROADS PKY N SUITE 205 LA PUENTE, CA 91746
88753 SQUARE D CO 3516 CONCORD RD YORK, PA 17402


Legacy KB System (APS) Data: RESL206488 V1.0, Originally authored by MaTh on 10/26/2011, Last Edited by MaTh on 10/26/2011
Related ranges: Standards Applied to Power Management PRODUCTS

What are the nine current settings on the Vigirex relay catalog number 56372 (56372TD), or RH99M?

Product Line:
Circuit Breakers

Environment:
Electrical Distribution Equipment

Resolution:
The settings are 30ma, 100ma, 300ma, 500ma, 1A, 3A, 5A, 10A, 30A.

What is the part number for flush surround for mounting 56SW320?

The part number for flush surround for mounting 56SW320 is - 56FA1 & 56FA1B

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=56FA1

User-added image

What IP rating is the 56JB1?

The 56JB1 has an IP Rating of 66.

For more information, please refer to the link:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=56JB1 

Will 56RCLE fit in 56ES1 shallow base?

56RCLE has a total depth of 65mm of which 28mm is the protrusion into the back box. The total depth of 56ES1 is 38mm. Fitting 56RCLE on 56ES1 will provide only 10mm wiring room.
Please refer to the below drawings for more details:

For further information, please visit:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=56RCLE
https://www.clipsal.com/Trade/Products/ProductDetail?catno=56ES1

What are the dimensions of of a 56JB1?

The dimensions of the 56JB1 are 101 x 101 x 91mm high.

Some of the key features are:
  • Surface mount
  • 1 gang
  • Screw on fastening
  • Screwed cover attachment
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56JB1


 

Do you have a weather proof junction box available 100mm X 100mm?

Yes, we do have a weatherproof junction box. The part number that best meets this description  would be the 56JB1 then dash colour code.

Some of the key faetures are:
  • Surface mount
  • 1 gang
  • Dimension: 91 mm Height x 101 mm Width x 101 mm Depth
  • Screw on fastening
  • Screwed cover attachment
  • IP66 international protection rating
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56JB1
 

What is the part number of the mounting enclosure/ backbox supplied with 56PB, IP66 start control station?

56ES1 is the part number  of the mounting enclosure/ back box supplied with 56PB, IP66 start control station.

Key Features

  • 1 gang shallow
  • 1 x 25 mm, 1 x 20 mm conduit entries
  • Dimensions 101 x 101 x 38mm high
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56ES1

Are there any system variables that can monitor the Communication Status in Vijeo Designer ?

There are a collection of statistic variables that can be used to monitor the communication of any driver (serial or ethernet).Here is a table describing those statistics:Current Statistics (@stat) and Previous Statistics (@prevstat)
The driver collects the current and previous statistics listed in the 
following table. In the variable's Device Address field, use @stat or @prevstat to identify whether you want to view 
the current statistics or previous statistics, then type a colon and the index 
number.
Examples:
@stat:2 = Total Count
@prevstat:8 = Initialization Failed
For details on how to set up variables so you can display driver statistics, see Section 5.3.1 of the Online Help, "Creating Variables to Display Driver Statistics."

To utilize these statistic variables, simply create an External variable assigned to your Modbus RTU equipment and assign the device address @stat:0 for Total good packets or @stat:1 for Total bad packets.There are other statistics that you could monitor to check for good/bad communication as the table indicates.