skt o/lt ip66 2apt 30mech

Aperture Enclosure, 2 Gang

Catalogue Number: 56/32
skt o/lt ip66 2apt 30mech
Colour: Grey
Colour: Per UOM Std.
  • Chemical Grey 1 PCE
  • Grey 1 PCE
  • Resistant Orange 1 PCE
  • Resistant White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
Series 56
Range
Clipsal - 56 Series
Product brand
Clipsal
Product or component type
enclosure
Plug, socket category
low voltage
Outlet standard
industrial
Colour
grey (RAL 7035)
Cover type
transparent
Number of gangs
2 gangs
Shape
square
Device mounting
surface
Cable entry number
2
Material
polycarbonate: cover
Fixing mode
by screws
Tightening torque
0.8 N.m
Length
107 mm
Width
101 mm
Depth
77 mm
Height
107 mm
Net weight
0.36 kg
IP degree of protection
IP66
Targeted country
Australia
Market segment
  • small commercial
  • industry
  • utility
    • Compatibility code
      30 Mech
      Ambient air temperature for operation
      -25-75 °C
      EU RoHS Directive
      Compliant

      Documents & downloads

      hide show
      Filter items
      • All

      • Product Brochures

      • CAD Files and Packs

      • Technical Data Catalogues

      • Installation Instruction

      • Specifications

      • Corporate Marketing

      Frequently Asked Questions

      hide show

      Is part number 56/32 pad lockable?

      Yes part number 56/32 can be pad lockable.

      Is there one gang vesion of 56/32 adaptable enclosure to take 30 series mechanisms?

      Unfortunately not. We do not have one gang version of 56/32. The unused gang can be blanked off using 30P, blanking mechanism.
      For further information, please visit
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=56/32
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=30P

      Is part number 56/32 available in single gang?

      No. Unfortunately, part number is not available as single.

      Do you do a 56/32 with one spot for a 30 mech not two?

      No unfortunately we dont make that part you would need to place a 30P to fill one of the holes.

      What IP66 enclosure can be used for 30 series mechs?

      Part no 56/32 has IP66 rating and can be used for

      30 series mechs

      What length is the longest PDL mounting screw available?

      The PDL204 is the longest Screw Length we have and that is 50mm.
      A longer screw would need to be sourced through a third party. the Thread type is 6/32 UNC

      What is part no for pendant outlet to suit 56C432

      Part no 56SPOK

      What are the nine current settings on the Vigirex relay catalog number 56372 (56372TD), or RH99M?

      Product Line:
      Circuit Breakers

      Environment:
      Electrical Distribution Equipment

      Resolution:
      The settings are 30ma, 100ma, 300ma, 500ma, 1A, 3A, 5A, 10A, 30A.

      Does the bridge for PDL 56PE2 come with the product

       Yes it does

      What is part number for easy 56C332?

      The part number for easy 56C332 is EY56C332

      Can you buy a 56PB2 without a lable

      No

      Is part number 56C320 available in Dark Grey?

      Yes. The part no 56C320 - WW is the Dark Grey colour for this part it is standard.

      What is the smallest round pin plug in the 56 series

      The smallest is the 56P320

      What is the cap for a 56CSC310?

      56SC2

      Is the 563L2 still available?

      Yes, the 563L2 is still part of our range.

      Some of the key features are:
      • 3 cables
      • Grey insulated
      • Extended

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=563L2





       

      Do you do the 56P532 and the 56CSC532 in grey?

      The 56P532 is available in grey the 56CSC532 is not available in grey.

      Is there a 32/32 version of the 56E1 available?

      No. There is only a 56E1/20/20 or 56E1/25/25 available.

      Can I get a 56JB2 with a clear lid?

      No, but you can get a clear lid separately.
      The part number is 56L2-TR.

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56L2

      What is the 56 Series box for flush mounting PDL 56E2 enclosure

       PDL 56FA2

      Is the centre pin a guide for the PDL 56P532

      The PDL 56P532 the centre pin is a neutral not a guide
      3 phases Neutral and Earth

      Can i get a 56C532 in an appliance inlet?

      Yes, however you will need to assemble it yourself. The parts you will require are:
      1. 56E3 -(3 Gang base)
      2. 56AI532LE -(Appliance inlet 5 pin 32A less enclosure)
      3. 56SW332LE -(3 Pole switch 32A less enclosure)

       

      Is there a 56C532 with a key switch?

      No, however it can be made up from part numbers 56E2, 56SO532LE and 56K1SW332LE.


       

      What is the mounting bracket to suit Prestige large format plates?

      Part number 156/2 can be used on all Prestige large format plates.

      Does the PDL 56FA2 come with a flush box

      No, it comes with a gasket and metal mounting plate to fix to the surface to make the switch / socket flush

      What is the part number for flat 3 pin 32a switch socket combo in 56 series?

      the part number is 56332. we do not do it in flat pin only round.

      What is the part number for a lid/cover for the 56ES2?

      The part number for a lid/cover for the 56ES2 is - 56L2
      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=56L2
      User-added image

      what is the code for a 56 series 3 phase 32A plug with phase and neutral

      56P532 (STRAIT)
      56PA532 (ANGLED)

      Can a 56PB2 be mounted horizontally (face up) in a wet area?

      It is not recommended if there is another option as the IP66 rating doesn't allow for immersion in water, which is what happens if water pools in the lid.

      What is the plug to suit a 56C332?

      The plug to suit the 56C332 is the 56P332.
      For further information, visit the link below:-​
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=56P332
       

      What is the part number for a 56C310 with a deep base?

      The part number for a 56C310 with deep base is - 56ED2 & 56C310LE

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=56ED2
      https://www.clipsal.com/Trade/search-results?q=56C310LE
      User-added image

      What bracket is used to suit the larger Prestige range.

      The bracket would be the 156/2.
      This is also available in a wall box version as a157/2.
      Please see below documentation for more information.
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=156/2

      Does the flush surround 56FA2 work with the Easy 56 Series as well as the standard 56 Series?

      Yes the flush surround 56FA2 does work with the Easy 56 Series as well as the standard 56 Series?
      Some of the key features are:
      • Enclosures and Boxes
      • Flush surround suits 2 Gang 56 Series (157 x 254mm).
      • Temperature range -25C to +75C.
      For further information please visit www.clipsal.com/Trade/Products/ProductDetail?catno=56FA2


       

      What is the part number for a 56P532 angled internal?

      The part number for a 5pin 32A angled internal pin housing is 56PA532G.

      Some of the key features are:
      • Internal pin housing
      • 5 Round pins
      • 2.5-16 sq mm Conductor terminal
      • Polyester housing
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56PA532G
       

      What is the part number for the plug that fits the 56C532?

      The part number for the plug that fits the 56C532 is - 56P532
      For further information visit link below:-
      https://www.clipsal.com/Trade/search-results?q=56P532
      User-added image

      What is part for ezy 56 version of 56C532?

      The part number is a - EY56C532

      For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=EY56C532


      User-added image

      What size conductors will fit in a 56C532?

      The maximum conductor size that will fit in a 56C532 is 16mm2.

      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56C532

       

      What is the dimension of 90BD2 insulating shroud?

      The dimension of 90BD2 insulating shroud is 105mm(length) 78mm(width) 65mm(depth). 90BD2 insulating shroud, large type format, deep type, meets double insulation requirements (suits 156/2 metal brackets).
      For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=90BD2
      User-added image

      Is there a 56 series outlet to suit a 56P432 that restricts the plug from being removed when switched on?

      Yes, use of the 56CVI432 series will restrict removal while the outlet is switched on as there is an interlocking pin to hold the plug in place.
       
      Some of the key features are:
      • 32 A thermal current
      • Internal interlock switch
      • 4 round pins
      • 500V
      • IP66
      • 3 Pole
      • Vertical
      For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56CVI432 


       

      Getting error 5603 on LXM32 when I run a BMH motor

      Issue:
      Getting error 5603 on LXM32 when I try to run a BMH motor

      Product Line:
      Lexium 32
      LXM32


      Resolution:
      Error 5603 is a commutation error. This is usually due to a bad encoder. The BMH motor has to be sent back for repair or replacement.

      What is the operating temperature of the 563/1 and the 563/2 1 and 2 screw bluepoints?

      Our connectors are made of Polypropylene (which is a flame retardant material) according to the supplier this material can hold up top +-165C.
      Although I will not recommend more than room temperature + 40C.
      Keep in mind cables will not stand such temperature anyway as they normally rated between 75C to 90C

      Some of the key features are:
      • Cable Connectors
      • Single or double screw
      • Clear insulated
      • Suits up to 2 x 6mm² cables


       

      What is the part number for the replacement internal pins for the 56P532?

      The part number for the replacement internal pins for the 56P532 is - 56PA532G

      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=56PA532G

      User-added image

      In the 56 series will 56P510, 5 pin, 500V, 10A plug fit into 56SO532, 5 pin, 500V, 32A socket?

      Unfortunately not, 56P510 cannot be plugged into 56SO532 as 56P510 is a size 1 plug. 56P532 is the recommended plug to use with 56SO532.
      For further information, please visit
      https://www.clipsal.com/Trade/Products/ProductDetail?catno=56P532

      Fuse and circuit breaker rating for LXM32

      Issue:
      What is the fuse or circuit breaker rating for LXM32 drives?

      Product Line:
      LXM32

      Resolution:
      For 115VAC and 230VAC drives, the maximum fuse to be connected upstream is 25 Amps, Class CC or J as per UL 248-4, alternatively circuit breakers with B or C characteristic.
      For 400VAC and 480VAC drives, the maximum fuse to be connected upstream is 30/32 Amps, Class CC or J as per UL 248-4, alternatively circuit breakers with B or C characteristic.

      What is the part number to flush mount a 56 series switched outlet that would normally go on a 56E2 base??

      The part number to flush mount a 56 series switched outlet that would normally go on a 56E2 base is - 56FA2 & 56FA2B
      For further information , visit link below:-
      https://www.clipsal.com/Trade/search-results?q=56FA2
      https://www.clipsal.com/Trade/search-results?q=56FA2B

      User-added image
      User-added image

      An Example of a DNP Variable Tag in PowerSCADA Expert to Read Analog Input

      Issue
      After adding a third party device with DNP protocol one needs to add variable tags to read realtime values.

      Product Line
      PowerSCADA Expert (any vesion that supports DNP)

      Environment
      Variable Tags
       
      Cause
      Setting up tags to read data from the physical device.

      Resolution
      General format for reading Analog Input Value (16/32 bit) is:
                AI<i>.VAL

      Examples:
      AI0.VAL
      AI1.VAL
      AI8.VAL

      The user should refer to the device user guide to find the DNP mapping.  In this example i=0 corresponds to Vln a:

                

      Refer to Driver Help for complete listing of Addresses used for different data types.
       

      What is the part number of the flush surround to suit 56CV, one piece cover, switched outlets?

      56FA2 is the part number of the flush surround to suit 56CV, one piece cover switched outlets. Surface mounted 56 Series Sockets, Switches and Combinations can be transformed into flush mounting equivalents using the 56FA Surrounds and Brackets. The surrounds can be used on various types of walls to ensure a neat installation, such as:
      • a mounting enclosure (back box) in poured concrete
      • a bracket on brick, brick veneer or panel walls.
      The brackets provide the installer with a  practical method of flush mounting 56 Series accessories. Comprehensive installation instructions are supplied with all units.
      56FA1, 56FA2, 56FA3 and 56FA4 Flush Surrounds contain a moulded flange, foam gasket and stainless steel mounting screws.
      For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56FA2

      What are the Commercial and Government Entity (CAGE) codes for Schneider Electric (US only)?

      The CAGE codes for Schneider Electric/SQUARE D are listed below:
      CAGE Code Company Address
      04429 SQUARE D CO LEEDS MFG PLANT 940 MOORE ST NE LEEDS, AL 35094
      05684 SQUARE D CO MIDDLETOWN MFG PLANT 1500 S UNIVERSITY BLVD MIDDLETOWN, OH 45044
      07442 SQUARE D CO DALLAS ASSEMBLY PLANT 1111 REGAL ROW DALLAS, TX 7524
      12670 SQUARE D COELECTROMAGNETIC INDUSTRIES DIV 1410 DONALDSON PIKE B-5 NASHVILLE, TN 37217
      14280 SQUARE D CO LEXINGTON MFG PLANT 1601 MERCER RD LEXINGTON, KY 40511
      14799 SQUARE D CO CHICAGO ASSEMBLY PLANT 9522 W WINONA SCHILLER PARK, IL 60176
      19804 SQUARE D CO GRAND BAY OF BRECKSVILLE 6995 S EDGERTON RD SUITE 100 BRECKSVILLE, OH 44141
      2E203 SQUARE D CO 810 GLEN EAGLE CT SUITE 100 BALTIMORE, MD 21286
      4T466 SQUARE D CO 1010 AIRPARK CENTER DR NASHVILLE, TN 37217
      51917 SQUARE D CO ASHEVILLE MFG PLANT 128 BINGHAM RD ASHEVILLE, NC 28806
      51918 SQUARE D CO AUTOMATION AND CONTROL BUSINESS RALEIGH, NC 27611
      51920 SQUARE D CO COLUMBIA MFG PLANT SUMTER HWY 76 AND 378 COLUMBIA, SC 29209
      55947 SQUARE D CO SORGEL MFG PLANT 4065 N RICHARDS ST MILWAUKEE, WI 53212
      56158 SQUARE D CO OSHKOSH MFG PLANT 3300 MEDALIST DR OSHKOSH, WI 54901
      56302 SQUARE D CO CEDAR RAPIDS MFG PLANT 3700 6TH ST SW CEDAR RAPIDS, IA 52406
      56303 SQUARE D CO 1717 CENTER PARK RD LINCOLN, NE 68512
      56304 SQUARE D CO OXFORD MFG PLANT 5735 COLLEGE CORNER RD OXFORD, OH 45056
      56365 SQUARE D CO CORPORATE OFFICES 1415 S ROSELLE RD PALATINE, IL 60067
      63637 SQUARE D CO MISSOURI MFG PLANT 4800 PARIS RD COLUMBIA, MO 65202
      63831 SQUARE D CO HUNTINGTON PLANT 6 COMMERCIAL RD HUNTINGTON, IN 46750
      70745 SQUARE D CO SENECA PLANT 1990 SANDIFER BLVD SENECA, SC 29678
      88434 SQUARE D CO 13191 CROSSROADS PKY N SUITE 205 LA PUENTE, CA 91746
      88753 SQUARE D CO 3516 CONCORD RD YORK, PA 17402


      Legacy KB System (APS) Data: RESL206488 V1.0, Originally authored by MaTh on 10/26/2011, Last Edited by MaTh on 10/26/2011
      Related ranges: Standards Applied to Power Management PRODUCTS

      Do we make a 56DB2 backet as a spare part?

      Unfortunately we do not to this as a spare part. However, it can be ordered as a special.

      Use the order code GCR_56_MISC

      The part number is 56DB2PANEL