Powertag Wiser Energy M 63A 1P+Wire

Powertag Wiser Energy M 63A 1P+Wire

Powertag Wiser Energy M 63A 1P+Wire

Item Number: 4CBEM1

Retail
$252.52
RRP (Inc. GST)

Product Dimensions

Width icon

Width18 mm

Height icon

Height16.5 mm

Depth icon

Depth43 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

PowerLogic

Product or component type

energy sensor

Product brand

Clipsal

Market segment

  • residential: breaker voltage monitoring
  • residential: overload alarm
    • Product destination

      switchboard

      Sustainable offer status

      Green Premium product

      Physical

      Range compatibility

      Resi MAX & MAX4

      Mounting support

      on circuit breaker

      Mounting mode

      by screws (terminals)

      [Ue] rated operational voltage

      200...240 V AC, +/- 20 %

      Standards

    • IEC 61557-12
    • IEC 61010-1
    • IEC 61010-2-030
    • IEC 61326-1
    • ETSI EN 300 328
      • Height

        16.5 mm

        Width

        18 mm

        Depth

        43 mm

        Net weight

        16.4 g

        Ambient air temperature for operation

        -25-60 °C

        Ambient air temperature for storage

        -40-85 °C

        IP degree of protection

        IP20 conforming to IEC 60529

        IK degree of protection

        IK05

        Relative humidity

        0-95 % at 45-45 °C conforming to IEC 60721-3-3

        Environmental characteristic

      • dustproof class 3S3 conforming to IEC 60721-3-3
      • salt mist class 3C2 conforming to IEC 60721-3-3
        • EU RoHS Directive

          Compliant

          Mercury free

          Yes

          RoHS exemption information

          Yes

          China RoHS Regulation

          Product out of China RoHS scope. Substance declaration for your information

          Environmental Disclosure

          ENVPEP1605012

          Circularity Profile

          ENVEOLI1605012

          Others

          Product name

          PowerTag Wiser M63

          Poles description

          1P

          Max current

          63 A

          [Ib] basic current

          10 A

          Starting current

          40 mA

          Saturation current

          130 A

          Product specific application

        • load monitoring
        • circuit monitoring
        • overload alarm
        • energy production monitoring (photovoltaic)
        • energy management
          • Concentrator compatibility

            Wiser IP module

            Type of measurement

          • current
          • voltage
          • active energy
            • Accuracy class

            • class 1 current conforming to IEC 61557-12
            • class 0.5 voltage conforming to IEC 61557-12
            • class 1 active energy conforming to IEC 61557-12
              • Mounting location

                top or bottom

                Event management

                voltage loss with measured current at voltage loss

                Transmission support medium

                radio frequency 2.4-2.4835 GHz conforming to IEEE 802.15.4

                Maximum emission power

                10 mW

                Form factor

                monoconnect

                Electrical connection

                connector tooth and wire

                Cable cross section

              • 1 rigid cable 1.5-16 mm²
              • 2 stranded cable 1.5-2.5 mm²
              • 2 rigid cable 1.5-2.5 mm²
              • 1 stranded cable 1.5-16 mm²
                • Cable length

                  1 m

                  Cable composition

                  1 x 0.33 mm²

                  Network frequency

                • 50 Hz
                • 60 Hz
                  • Maximum power consumption in VA

                    1 VA

                    Quality labels

                    CE

                    Directives

                    2014/53/EU - radio equipment directive

                    Operating altitude

                    0...2000 m

                    Overvoltage category

                    III conforming to IEC 61010-1

                    Measurement category

                    category III conforming to IEC 61010-2-030

                    Pollution degree

                    3

                    Vibration resistance

                    3M4 conforming to IEC 60721-3-3

                    Package 1 Weight

                    0.04 kg

                    Package 1 Height

                    0.5 dm

                    Package 1 width

                    0.6 dm

                    Package 1 Length

                    0.85 dm

                    WEEE

                    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                    Show all specifications

                    Documents & downloads

                    hide show
                    Filter items
                    • All

                    • Product Environmental

                    • End of Life Manual

                    • Certificates (MSDS)

                    Frequently Asked Questions

                    hide show

                    Can the ECC21 display ITIC / CBEMA curves?

                    Goals and Symptoms

                    Goal
                    To add the ITIC / CBEMA webpage option to the ECC21.

                    Causes and Fixes

                    Cause

                    By default the ECC21 card does not have the CBEMA curve webpage pre-loaded


                    Resolution

                    FTP the ITIC.htm file to the ECC21 to enable ITIC / CEBEMA graphs

                    1. Download the attached ITIC.htm file to the root of C:\
                    2. Open a Windows Command Prompt (cmd)
                    3. Enter "ftp xxx.xxx.xxx.xxx" where the x's correspond to the IP address of the ECC21
                    4. When prompted, enter the ECC user name "admin"
                    5. When prompted, enter the admin password. The default password is "admin"
                    6. Enter "send C:\itic.htm"


                    ITIC.htm



                    Example ITIC graph


                    Legacy KB System (APS) Data: RESL200365 V1.0, Originally authored by MaTh on 10/28/2009, Last Edited by MaTh on 10/28/2009
                    Related ranges: ECC21

                    Why does my SMC Series Smart-UPS switch to battery when it encounters high voltage?

                    Issue: 
                    "SMC" series Smart-UPS switches to battery when it encounters high input voltage.
                     
                    Product line:
                    Smart-UPS SMC
                     
                    Environment:
                    SMC1000, SMC1500, SMC1000-2u, SMC1500-2u 
                     
                    Cause:
                    The SMC series of Smart-UPS feature boost-only voltage regulation. If input voltage rises above your high voltage transfer point, the UPS will switch to on-battery operation. This is normal.
                     
                    Resolution:
                    If you find your unit repeatedly switching to on-battery operation due to high input voltage, you can adjust the high voltage transfer point via Powerchute Business Edition. This gives you a wider range of acceptable input voltages and will allow your UPS to stay on-line in a wider variety of situations. Please note that this will also potentially expose your attached load to higher voltages, however it will never expose your load to anything outside of CBEMA standards for acceptable input voltage. If your application requires both boost and trim voltage regulation, we would suggest upgrading to an SMT or SMX series Smart-UPS.












                     

                    The PQDIF file extracted from an ION8650C is empty

                    Issue
                    The CBEMA log and the power quality report for the ION8650 indicate that a PQ event but the PQDIF extractor in PME 8.x creates an empty file for the specific time range. 

                    Product line 
                    ION8650C, PME 8.1

                    Environment
                    PQDIF extractor 

                    Cause
                    The ION8650's Sag/swell module doesn't have following outputs and therefore they are not logged in the database. 
                    1- SubV1Avg, SubV2Avg, SubV3Avg
                    2- DistV1Avg, DistV2Avg, DistV3Avg
                    The PQDIFF extractor default templates for the ION8650 meters requires a disturbance average quantity in order to generate a PQDIFF file. 

                    Resolution
                    The ION8650C, unlike the ION8650A and ION8650B, was not designed to be a power quality meter and has limited PQ capabilities. The meter by default records the min and max duration and the PQDIFF extractor can be modified  to export PQDIFF files from the ION8650C:

                    To Add a new custom template to PQDIFF that can export either the min or max disturbance values:
                    1. Navigate to PME_Directory\Schneider Electric\Power Monitoring Expert\config\exporters\PQDIF\templates
                    2. Add the files SagSwell_Voltage_Disturbance_max_values and SagSwell_Voltage_Disturbance_min_values to the folder.
                    3.  Restart the ION PQDIF Exporter Service and relaunch PQDIF exporter.
                    4. Select the new ION8650C templates and then run an export job in PQDIF exporter
                    The extracted files will contain either the mix or the min values. 

                    PM850/870 Device Reboots For No Apparent Reason in ION Enterprise \SPM \ PME

                    Issue
                    An ION Enterprise 5.6 SP1 or 6.0, StruxureWare Power Monitoring (SPM), Power Monitoring Expert (PME) system which includes a PM850 or PM870 device,
                    the device reboots periodically for no apparent reason.

                    Product Line
                    PM850
                    PM870

                    Environment
                    ION Enterprise 5.6 SP1, StruxureWare Power Monitoring (SPM), Power Monitoring Expert (PME)
                    PM850
                    PM870

                    Cause
                    There is a problem with firmware versions for PM8 devices prior to v10.8 which can cause the device to reboot if it is polled frequently.

                    Resolution
                    Upgrade the meter firmware to version 10.8 or greater. Upgrading the meter firmware will also allow the device to provide information required for a CBEMA plot.

                    Access to firmware upgrade instructions, including a how-to video and a link to the latest firmware can be found at:  Firmware Upgrade - Instructions and Downloads
                    If only the firmware is required, it can be downloaded directly from: https://www.schneider-electric.com/en/download/document/PM8xx_V12.5/

                    Or Alternatively,

                    1) Using a internet browser navigate to www.schneider-electric.com
                    2) select Support, then Download Center from the Green menu bar
                    3) type "PM800 Series V12.500 Firmware" into the search bar and click on the Search button
                    4) click on the "PM800 Series V12.500 Firmware" link presented in the search results
                    5) click on the Download button to start the download and save the file

                    Note: Also by entering only PM800 and/or keyword search criteria into the search bar, you be find wide variety of PM800 related documents.