Mech Switch Toggle 3-pos Blank 10A 250V

Clipsal Iconic Switch Mechanism, 3-Position Toggle, 250V, 10A

Catalogue Number: 49M
Mech Switch Toggle 3-pos Blank 10A 250V
Colour: Vivid White
Colour: Per UOM Std.
  • Vivid White 1 PCE
Added to cart

Specifications

hide show
Range
Clipsal Iconic
Product or component type
switch
Device application
lighting
Colour tint
vivid white
Quantity per set
set of 20
Device presentation
mechanism
Control type
rocker
Switch function
3 positions
Marking
ON-OFF-ON
Rated current
10 A
[Ue] rated operational voltage
250 V
Connections - terminals
screw terminal
Height
23 mm
Width
23 mm
Depth
32 mm
Net weight
0.016 kg
EU RoHS Directive
Compliant
Environmental Disclosure
ENVPEP120506EN

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • Certificates (MSDS)

Frequently Asked Questions

hide show

Is part number 49M available in Anthracite?

No. Unfortunately, the part number 49M  is only available in Vivid White.

What is the part number for an Iconic 3 position switch mech , labelled UP , OFF , DOWN?

The part number for an Iconic 3 position switch mech , labelled UP , OFF , DOWN is - 49M & 49MLBL

For further information , visit links below:-
https://www.clipsal.com/Trade/search-results?q=49M
https://www.clipsal.com/Trade/search-results?q=49MLBL
User-added image
 

Does the Clipsal 438/2 suit the 492

The 438/2 does suit the 492. 

What is the female version of a 492

 The female version is 438/2

Do we make a 39M in spring return?

No.Unfortunately we donot do it.

What is part number for 39M Marked Open/Off/Close?

Part number is a 39MOOC.

Is the Clipsal 39M series spring return

No, this series is not spring return

What mechs fit into Pro Series grids?

 Pro Series is compatible with all PDL300 Series & Clipsal 40M mechanisms.

What is part number for leads to suit 493?

The part number for leads to suit 493 is a 493L.

What is the difference between the 492 and 492Y ?

The 492 is designed to suit  2 core 1mm2 ordinary duty flex while the 492Y is designed to suit 0.75mm2 figure 8 flex.
For more information regarding this and similar products please follow the link provided to the Clipsal website.
https://www.clipsal.com/Trade/search-results?q=492
User-added image

What extension socket suits the 492 plug?

The extension socket that suits the 492 plug is the 438/2.

Some of the key features are:
  • Rewireable cord extension socket
  • 2 Parallel pins
  • Suits 1 sq mm Ordinary duty 2 core flexible cord
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=438/2

 

What is Iconic part no for cap to suit 40M

Part no 40AR
for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=40AR-WY

User-added image

 

Is there 39M marked UP, OFF DOWN?

The part name is as follows: 39MUOD

What is the part number for 39M mechanism marked UP & DOWN?

The part name is as follows: 39MUOD-WE

What is the part number for a multi deck screw terminal block for 4mm cable?

The part number for a multi-deck screw terminal block for 4mm cable is - NSYTRV44D

For further information, visit the link below:-
https://www.schneider-electric.com.au/en/search/NSYTRV44D
User-added image

 

Can I get spare aligator clips for the 493 sparke mate leads

No, but you can get the lead kit by itself

What is the cable capacity for a 56P320F?

Maximum 4mm (QC) and 6mm (screwed).

What is part no for 39m mech no marking

Part no 39MPLAIN

for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=39MPLAIN

User-added image

What is the socket to suit the Clipsal 492 492/32 492/32HD

Socket to suit is 402 series

402  402/32

What is part no for cord to suit 493

Part no for cord to suit 493

for more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=493L

User-added image

How to upgrade the coprocessor's firmware of UNITY HSBY 140 CPU 67160?

To upgrade the copro firmware of the 140CPU67160 (using OSLoader), you need to use the fibre optic MTRJ port and switch which as fibre optic and electrical RJ45 ports (such as the 490 NOC 000 05 cable and 499 NOS 171 00 switch).

There are no other method available at this moment.

Other related information
To upgrade the firmware of UNITY Quantum CPUs (using OSLoader), you can either use one of the following way:
- Modbus (with address 1 only)
- Modbus plus (with address 1 only)

To upgrade the copro firmware of HE 140CPU65150 and 140CPU65160 (using OSLoader, you need to use the ethernet coneection via FTP.


Legacy KB System (APS) Data: RESL168369 V1.0, Originally authored by on , Last Edited by on
Related ranges: Modicon Quantum

Updated: Why is my Network Management Card losing SNMPv3 communication?


Issue

My Network Management Card (NMC) is losing SNMPv3 connectivity after a certain amount of time but other communication protocols (web, FTP, SSH, Telnet, SNMPv1, etc) continue to work properly.


Product Line

 

  • Network Management Card 1 (NMC1) - AP9617, AP9618, AP9619
    Devices with an embedded Network Management Card 1 include (but are not limited to): Metered/Switched Rack PDUs (AP78XX, AP79XX), Rack Automatic Transfer Switches (AP77XX, Environmental Monitoring Units (AP9320, AP9340, NetBotz 200)
     
  • Network Management Card 2 (NMC2) - AP9630/AP9630CH, AP9631/AP9631CH, AP9635/AP9635CH
    Devices with an embedded Network Management Card 2 include (but are not limited to): 2G Metered/Switched Rack PDUs (AP86XX, AP88XX, AP89XX), Certain Audio/Video Network Management Enabled products.
     
Environment
 
  • All serial numbers
  • Any device listed above utilizing SNMPv3
  • NMC1 AOS v3.7.0 and below; NMC2 AOS v5.0.X and below
  • NMC1 AOS v3.7.3 and higher


Cause

An issue has been identified with the SNMPv3 task on Network Management Card 1 and 2 based devices. SNMPv3 communication will be lost after approximately 49 days and 17 hours. The NMC will continue to run normally, with the exception of the SNMP process, which will not run.


Resolution

Update (July, 2016): Specific to NMC1 products, this issue had previously been fixed for AOS 3.7.3 and higher. The maximum SNMPv3 uptime allowed was modfied from 49.7 days to 497 days. At the 497 uptime day mark, assuming the management uptime had reached this point, the Network Management Card interface would have had to be rebooted though the web, CLI, or SNMPv1 interfaces in order to regain SNMPv3 communication. NMC2 AOS v5.1.X also contained a fix to avoid an SNMPv3 communication loss completely.

With NMC1 AOS v3.9.2 and higher, this issue has been fully resolved and the 497 uptime limitation has been lifted and SNMPv3 communication through StruxureWare Data Center Expert or any third party SNMPv3 NMS will not be affected after 497 days of uptime. This AOS (or newer) will be released for different firmware applications in the coming months which are available at https://www.apc.com/tt/en/tools/download/. Certain applications are available immediately, such as Rack PDU.
 

Is there a Spark-e-Mate Multi Tester Calibration Service available for both 493 (Standard) and 493BTL (Bluetooth)

Yes.  Calibration service is offered via Customer Care phone 0800 652 999.  Similar method to RMA's.

What does the 493 / 493BTL come with when ordered?

Nothing - you will need to order the leads (493L) and shoulder bag/pouch (493SB) as separate products.

What is the part code for the Fuse disconnect 4mm Linergy NSY with LED Indication?

The part code is NSYTRV42SF5LD

Follow the link for data sheet : https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=NSYTRV42SF5LD
 

What is part number for socket to suit part number 492?

The part number for socket to suit is a 438/2
For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=438/2


User-added image

Do you have a 413QC that can be used with 4mm cable?

No, the 413QC can only be used with cable up to 2.5mm

Some of the key features are:
  • Quick connect in line surface socket
  • 3 pins
  • Round earth pins
  • 1 sq mm to 2.5 sq mm solid/stranded to AS/NZS5000 conductor range
  • Terminate up to 2 sets of Active, Neutral & Earth conductors
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=413QC

Do Clipsal make a 3 position mech with "up, off and down" printed on it?

Yes we do. The part number is 39MUOD.
For more information on this range please visit the Clipsal web site on the link  provided https://www.clipsal.com/Trade/search-results?q=39muod

How often should the 493 sparkemate multi tester be calibrated?

The Spark-e-mate is not required to be routinely calibrated, but if calibration is required (as per ECANZ) please consult Design 2000 Pty Ltd Melbourne, Victoria. There will be a charge involved.
https://www.design2000.com.au/services.php
Spark-e-mate instructions attached.

What are the cutout dimensions of the F30Z4

The F30Z4 suits 4mm thick steel of which any 30 series switch mechanism can be installed.
the cut out is 25.4MM SQARED

Can I upgrade my old model of Spark-e-mate to have advanced RCD testing?

The item can be upgraded by returning to the manufacturer - Design2000.

The below link has details for the RMA process with Design2000 where the customer could get the unit updated.

https://www.design2000.com.au/services.php

 

Is it possible to get a 2000 series single GPO printed with RCD protected?

Yes, it is available as a single GPO
2015-GRRCD
4mm pad printed in green
RCD protected

Slimline = 4mm thick does that include the rocker switch ?

no - would need to use a pushbutton but this would add an extra approx 2mm
BSL would be a slimmer option with a pushbutton

Can my old Spark-e-Mate have a bluetooth chip installed?

All callibration and services regarding the 493 Sparke mate range is done via a third party manufacturer Design2000.

DESIGN 2000
Phone: +613 97585933
9-11 Rose St PO Box 7020 
Upper Ferntree Gully, Melbourne, Victoria, 3156

Can Power Supply ABL7RM 24025 be din rail mounted?

Yes, ABL7RM24025 can be din rail mounted, it also has 2 x 4mm panel mount holes.

 

What size cable does the 60R32 accommodate?

The 60R32 switch mechanism accommodates up to  4 x 1.5mm2 or 3 x 2.5mm2 or a single 4mm or a single 6mm.

Where do I send a Spark-e-mate for repairs?

For repairs on the 493 you would contact Design 2000.

Please follow this link for contact details https://www.design2000.com.au/services.php

 

Is Wiggy voltage tester available in Australia?

Unfortunately not, Wiggy voltage tester is not available in Australia. Clipsal offers 493 multi function tester for the Australian market. For further information on 493, please visit  https://www.clipsal.com/Trade/search-results?q=493

 

What is the equivalent to a Mistral 6111-0 window exhaust fan?

The equivalent is a Clipsal 7107A - though the cut out hole size is a lot smaller so will not retrofit without replacing the glass.

Specifications - 6111-0
Airflow = 490 cubic metres per hour
Hole size = 282.5mm
Fan diameter = 250mm
Motor = 66w
Sound level at 1m = 53dB

Specifications - 7107A
Airflow = 600 cubic metres per hour
Hole size = 230mm
Fan diameter = 188mm
Motor = 35w
Sound level at 1m = 49dB

What is a 'Sliding Window' in Transparent Ready TCP communications and do Transparent Ready devices support it?

A Sliding Window is a variable receive buffer capacity that is advertised in the 16 bit Window packet section of the TCP Header. This is how a transmitting device advertises the current receive buffer capacity to the sender. The 174CEV30010 and 174CEV30020 Modbus to Ethernet bridges support a sliding window. For example, if the CEV buffer starts out at 512 bytes capacity and there is an outstanding Modbus message size of 14 bytes, the advertised window will be 498 bytes in the response. Note that most PLC services support a fixed receive buffer window size.


Legacy KB System (APS) Data: RESL173844 V1.0, Originally authored by on , Last Edited by on
Related ranges: Modicon Quantum

Generator does not charge my batteries using the XW or SW models?

Generator is not charging the batteries

If the inverter/charger qualifies the signal but the unit goes right away to passthrough, please check the following
Make sure Charger is enabled
Confirm that the Charger Block Start/Stop is not enabled during the times that you want it to charge

NOTE:Ex.  If the Charger Block Start is set at 4:00am and the Charger Block Stop is set at 11:00pm, that means that it will not charge between 4am and 11:00pm.
It would only charge from 11:00pm to 4:00am
Tip:If there is no need to block the charging then set the start/stop times to 12:00am to disable the feature

What is the part number of a 30 series, three position mechanism marked HI - Off -LO?

39M is a 10A, 30 series mechanism, three position marked HI - Off -LO.

Key Features

  • 3 Terminals
  • 3.5mm diameter accommodate 2 x 2.5 sq mm cable
For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=39M

What is the part number for a 2 gang Iconic switch plate and switch mech and dimmer?

The part number for a 2 gang Iconic switch plate and switch mech and dimmer is - 3042HA , 40M & 41E300PBUD2SM

For further information , visit link below:-
https://www.clipsal.com/Trade/search-results?q=3042HA
https://www.clipsal.com/Trade/search-results?q=40M
https://www.clipsal.com/Trade/search-results?q=41E300PBUD2SM
User-added image

Can Xanbus Cable be installed Underground for use with XW/XW+/CSW System?

Yes, but requires the use of proper outdoor/underground cables of the correct build and standard and is not to exceed the maximum length - Xanbus total 40m @ 250kbps.
Requires the use of Ethernet Cable designed for underground use. Can use CAT 5e or CAT 6 JELLY FILLED cable with correct outdoor rating and is compliant with local standards.
 

What is the maximum cable size for a 56P520?

The maximum conductor size for a 56P520 is 4mm sq with a maximum cable diameter of 15.7mm

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=56P520
 

Do you do a 30 Series mech with the engravings up and down on it?

No, unfortunately in a standard 30m we don't, however it could be done as a special.
We also offer a 3 position switch in the 39M series which is engraved with UP, OFF, DOWN. The part number is 39MOUD.

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=39MUOD.

What is the part number of a 3 position mechanism in the Saturn Zen range?

39M is a 30 Series, 3 Position 10A Mechanisms, Marked - LO - Off - HI. 30 series mechanism will fit on Saturn Zen  Z403*VH ( Example Z4031VH) Grid and Cover Assembly, accepts 30 Series Mechanisms (Including DATA/COMMS, 30PB and 30PBL)
* - 1, 2, 3, 4, 6
For further information, please visit:
https://www.clipsal.com/Trade/Products/ProductDetail?catno=39M

https://www.clipsal.com/Trade/Products/ProductDetail?catno=Z4031VH

 

What are the screw size and wire sizes for the CT and PT terminal connections on the CM4000 series meters?

Issue
What are the screw size and wire sizes for the CT and PT terminal connections

Product Line
CM4000
CM4250 
CM4000T

Environment
Hardware Specifications

Resolution
The terminal screws are 4mm with a 0.7 pitch. Each meter is supplied with spade lugs that accommodate 10-12 AWG wire.

Do you sell the 486 RCD tester leads as a spare part?

No, unfortunately this tester is no longer available. Therefore spare parts have also been discontinued.

This tester has been replaced with the all in one 493 Spark-E-Mate.

Some of the key features are:

  • Earth continuity
  • Insulation resistance
  • Polarity
  • Circuit connections 
  • fault loop impedance
  • RCD Trip
  • digital LCD dispay
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=493

E-FLEX enclosed drive - After the main breaker got tripped, the drive has no display and won't run.

Issue:  
E-FLEX enclosed drive - After the main breaker got tripped, the drive has no display and won't run.

Product line:
Altivar ATV61

Environment:
All models, all serial numbers 

Cause:
DC bus is only reading 14 VDC on PA + to PC -      

Resolution:
Checked Line voltage L1 L2 L3 they are all good  490 vac phase to phase. DC bus on PA to PC was only 14 VDC it should be 680 VDC. 
Suspect  a issue with the input diode circuit, soft charge board, power board and or DC bus capacitors. Power down and do an static check on the input side of the drive PA to L1 L2 L2 and PC to L1 L2 L3.
Show More