sock swt sing surf rem e/sw

Single Switch Socket Outlet, 250V, 10A, Removable Extra Switch, Surface Mount

Catalogue Number: 2015XSM
sock swt sing surf rem e/sw
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Range of product
Series 2000
Control type
ON/OFF button
Number of gangs
1 gang
Pin number
3
Number of power socket outlets
1
Actuator
  • switch
  • rocker
    • Mounting position
      horizontal
      Fixing mode
      by screws
      Local signalling
      without light indicator
      Material
      plastic
      Surface finish
      glossy
      [Ue] rated operational voltage
      250 V AC
      [In] rated current
      10 A
      Depth
      30 mm
      Length
      116 mm
      Width
      76 mm
      Fixing center
      84 mm
      Standards
    • AS/NZS 3100
    • AS/NZS 3112
    • AS/NZS 3133:approval number S/1
      • Sustainable offer status
        Green Premium product
        EU RoHS Directive
        Compliant
        Mercury free
        Yes
        RoHS exemption information
        Yes
        China RoHS Regulation
        Product out of China RoHS scope. Substance declaration for your information
        Environmental Disclosure
        ENVPEP120506EN

        Documents & downloads

        hide show
        Filter items
        • All

        • Product Brochures

        • CAD Files and Packs

        • Technical Data Catalogues

        • Specifications

        • Certificates (MSDS)

        Frequently Asked Questions

        hide show

        What is the PDL version of the 2015XX?

        The PDL version of the 2015XX is a PDL694XXWH.

         

        Can part number 2015X accommodate TV mech?

        A TV mech CAN NOT be put into 2015X. Must have at least 150mm of separation.
         

        Is there a C2015s with built in surge filter?

        No, we dont sell one complete, you would have to get a C2015XS take out the extra switch and put in a 30SFM.

        Is mech removable in part number 2015X?

        Yes, the mech in part number 2015X is removable.

        For more information on this part please refer to https://www.clipsal.com/Trade/Products/ProductDetail?catno=2015X


        User-added image

        Customer asked if the manual transfer switches are available with an interlocked receptacle option?

        No


        CTA-ID : 2015863

        Is there a double pole 15A outlet?

        Yes, the part number is a 2015D15

        What is part no for 15amp vertical single GPO

        PART NO 2015V15

        In the 600 Series, is the 691/15 available in RED

        Not available, but Clipsal 2015/15 is available in red but it's horizontal.

        Is there a 2000 series plate 2025 with an ID window like the 2025XUA with a 30PID?

        The part name is 2025XAPID-WE

        Is there a C2015XX cover in brushed aluminium?

        Yes, the part number for the cover in brushed aluminium is C2015XXC-BA

        Some of the features of the C2015XX are:
        • 2 Removable extra switch
        • Terminals suits 4 x 2.5 sq mm cables
        • 250V rated
        • 10A rated
        • C2000 Series
        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2015XX 

        Can I fit a USBC into a P2015X?

        Yes, you can put a USBC into a P2015X by using a P30Z as long as the extra switch is removable.

        Is there a 2000 Series plate 2025 with an ID window like the 2025XUA assembled with a 30PID?

        The part number for a 2000 Series powerpoint with an ID window like the 2025XUA assembled with a 30PID is 2025XAPID.
        Some of the key features are:
        • 30 PID
        • Removable extra switch
        • 10A
        • 250V
        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2025XAPID


         

        What is the part number for a cover for a latest vertical GPO with extra switch , C2015X?

        The part number for a cover for a latest vertical GPO with extra switch , C2015X is - C2015VXC2.

        For further information , visit link below:-
        https://www.clipsal.com/Trade/search-results?q=C2015VXC2

        What is the part number of a replacement button cap for an XB4BA21?

        Issue:
        What is the part number of a replacement button cap for an  XB4BA21?

        Product Line:
        Harmony Pushbuttons

        Environment:
        All Products

        Cause:
        Product selection

        Resolution:
        Use a ZBA2 black cap or otherwise the black cap from a universal ZBA9 kit


        CTA-ID : 2015097

        What is the part number for a diode for a CA3KN relay?

        Issue:
        What is  the part number for a diode for a CA3KN relay?

        Product Line:
        Tesys Relays

        Environment:
        All Products

        Cause:
        Product selection

        Resolution:
        LA4KC1B or LA4KC1E is the diode and zener diode for the CA3KN relay.


        CTA-ID : 2015604

        What is the part code for a very old PDL Shaver Socket Conversion Plate

        The conversion plate is no longer available but you can use the below part numbers for the Clipsal version
        2000/3-WE + 2015-WE + 2727-WE + 2031RC30-WE

        Are there double GPO's that are individually wired on each side?

        Yes, there are a few GPO's that are individually wired, they are C2016/2, 16/2MF, 2015/2V and 15/2V. In a weather proof option we have the WSC227/1/2

        What is part number for cover to suit C2015X?

        The part number is a - C2015XC.

        For more information on this part please refer https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2015XC


        User-added image

        Are the extra switches in the C2015XX removeable?

        Yes, the extra switches in the C2015XX are removable.

        Some of the key features are:
        • 2 Removable extra switch
        • Terminals suits 4 x 2.5 sq mm cables

        For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2015XX
         

         

        Can a factory-installed provision for a keylock be ordered with an NW breaker?

        Issue:
        Factory installation of key interlock provisions on NW Masterpact circuit breakers.

        Product Line:
        Circuit Breakers

        Environment:
        Products sold and used in the United States

        Cause:
        Factory installed key interlock on NW Masterpact circuit breakers

        Resolution:
        It is possible to order "provision-only" for an NW breaker key interlock. The provision is also available as a field-installable kit. See pricing guide for catalog numbers.

        CTA-ID : 2015133

        Why is the drive not responding to the 4-20mA feedback signal when the Pump Switching Card is installed?

        Most common issue is Parameter o19 must be set to the maximum pressure of the sensor in Bars.  Parameter o20 is set to the PI setpoint in Bars.

        To get the pressure in Bars, divide the pressure in PSI by 14.504.


        CTA-ID : 2015151

        What is the difference between the XACA201 and XACA205 pendant stations?

        Issue:
        What is the difference between the XACA201 and XACA205 pendant stations?

        Product Line:
        Pendant Stations

        Environment:
        All products

        Resolution:
        XACA201 has 1-NO contact on each button. The XACA205 has 1-NO on one button and 1-NC contact on the other button.

        Is the CA2KN22G7 DIN rail mountable?

        Issue:
        Is the CA2KN22G7 DIN rail mountable?
        Product Line:
        Industrial Relays
        Environment:
        Tesys K IEC Style Relays
        Cause:
        Determine how to mount for application.                             
        Resolution:                                                                 
        Yes. They are made to mount on 35mm DIN3 type mounting rail.
         

        Are parts still available for the obsolete CME product line?

        Issue:
        Old Product Design metering

        Product Line:
        Commercial Metering Equipement (CME)

        Ennvironment:
        Repair parts

        Cause:
        Maintenance

        Resolution:
        All CME parts are obsolete and no longer available. 


         

        What is the ampere rating for dc voltages for the 9001KA contact blocks?

        Issue:
        DC ampere rating for 9001KA contact blocks

        Product Line:
        Harmony Push Buttons

        Environment:
        Harmony 30mm

        Cause:
        Product Features

        Resolution:
        2.5A continuous up to moved. (NEMA Q600)

        Does Clipsal sell assembled double outlet with the USB charger mech?

        No , We have sinlge outlets with USB chargers or you can fit 1 x  USB charger mech to either a 2025XA or a C2025XA ( in vertical configuration )

        For further information on this please visit the clipsal web site on the link provided
        https://www.clipsal.com/Trade/search-results?q=30usbcm

        What is the part no for a double powerpoint with a larger space in between to use with power packs?

        The part no is 2015H2. It is 2 x single horizontal switched sockets side by side with a single frame.

         

        Is a double power point with neon & USB available in Red ?

        Part no 2025XAN can be used the USB has to mount vertically to enable it to fit

        Red is not a standard colour for this part but it can be made as a special

        What is the part number for a double GPO with Shutters and an ID window?

        The part number for a double GPO with Shutters and an ID window is - 2025XAS & 30PID

        For further information , visit links below:-
        https://www.clipsal.com/Trade/search-results?q=2025XAS
        https://www.clipsal.com/Trade/search-results?q=30PID
        User-added image
        User-added image

        Will 30USBCM fit on a C2000, Classic series plate?

        30USBCM will fit on C2015X / C2015XX / C2025X* / Up to 3-gang Classic series switch plates.
        For further information on 30USBCM, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=30USBCM
         

        What is the replacement part codes for RUMC2AB2 & RUM3CAB2?

        References changed in 2015
        RUMC2AB2•• becomes RUMC22••
        RUM3CAB2•• becomes RUMC32••

        the above codes use the same bases:
        RUMC22••/ RUMC2AB2•• = RUZC2M
        RUMC32••/ RUMC3AB2•• = RUZC3M

        What are the part number for a 15 amp outlet with RCD protection?

        Not available as 1 unit. Would have to use 2015/15 with 2031VRCD30
        For further information , visit links below:-
        https://www.clipsal.com/Trade/search-results?q=2015/15
        https://www.clipsal.com/Trade/search-results?q=2031VRCD30
        User-added image
        User-added image

        What are the dimensions for 8639 LPA4NA & LNA4NA?

        Issue: What are the dimensions for 8639 LPA4NA & LNA4NA?
         
        Product Line: 8639 ATS46
         
        Environment: 8639 LPA4NA & LNA4NA
         
        Cause: N/A
         
        Resolution: Theses are Floor mount unit at 34.21 inches wide, 92.68 inches tall, 26.00 inches deep with disconnect handle extended.

        The wieght is 850 lbs

        This is the same for class 8638 & 8639 Type NI - NQ standard duty and LM - LP heavy duty.


         

        What is the ATS48 line voltage operating range?

        Issue:
        What is the ATS48 line voltage operating range?

        Product line:
        Altistart 48, ATS48

        Environment:
        all

        Cause:
        n/a

        Resolution:
        The Altistart 48 is suitable for three phase supply voltages that range from 208VAC to 690VAC , 50/60Hz.  The tolerance of the voltage supply is -15% to +10%. 

         

        Are replacement contacts available for a CAD32 relay?

        Issue:
        Contacts need to be replaced in a CAD32** relay.

        Product Line:
        TeSys D IEC style relays

        Environment:
        CAD relays

        Resolution:
        The TeSys D IEC style relays do not offer replacement parts.  Replace entire device.

        Will the accessories used for the GV3ME06 through GV3ME63 work with the GV3ME80?

        Product Line:
        GV3 manual motor starters, IEC

        Resolution:
        The standard GV3 accessories will work on this device.

        What is the difference between 9001SKYP4 and SKYP40?

        Issue:
        What is the difference between 9001SKYP4 and SKYP40?

        Product Line:
        Harmony Control Stations

        Environment:
        All Products

        Cause:
        Product Features

        Resolution:
        9001SKYP4 is the enclosure only if customer wishes to order pendant station in components.
        9001SKYP40 is the enclosure catalog if customer wishes to order pendant station as completely assembled with operators, contact blocks and legend plates and requires key sheet.


         

        What is the lock out device for a 9001BW241?

        Issue:
        Is the lock out device on 9001BW241 sold separately?

        Product Line:
        Pushbuttons and Operator Interface

        Environment:
        9001B Standard Duty Control Stations

        Cause:
        Product Selection

        Resolution:
        The lock out is not offered as a separate item. Replace the cover with 9001BWD220 tha has a lockout factory installed on it.

        What is the difference between ZB2BZ101 and ZB2BE101?

        Issue:
        What is the difference between ZB2BZ101 and ZB2BE101?

        Product Line:
        Push Buttons

        Environment:
        22mm Push Buttons

        Cause:
        Product Features

        Resolution:
        ZB2BZ101 is a ZB2BE101 (normally open contact block) + ZB2BZ009 mounting collar




         

        Is there a padlock device for the 9001KR9R?

        Issue:
        What Padlock Device can be used on the 9001KR9R E-stop Pushbutton?

        Product Line:
        Harmony Pushbuttons

        Environment:
        All Products

        Resolution:
        9001K62, 9001K162
        NOTE: These attachments will not work when the operator is supplied with a 2 1/4 inch diameter mushroom.

        What is the part number for a Classic single GPO with 2 USB outlets in Black?

        The part number for a Classic single GPO with 2 USB outlets in Black is - C2015XX   + 30USBCM   +   USCBC-CAPS-BK

        For further information , visit link below:-
        https://www.clipsal.com/Trade/search-results?q=C2015XX
        User-added image

        Important security notification: M340, Quantum, Premium and STB Ethernet communication modules (ICS-ALERT-11-346-01)

        Goals and Symptoms

        Notification and recommendations concerning security as found in ICS-ALERT-11-346-01
        Updated Aug. 20, 2015
        This is an update to previous Resolution RES206895.

        Causes and Fixes

        See Attached document

        Attachments

        What is the part number for a replacement for 15/15/EL30?

        There is no direct replacement for this unit. Customer would be able to use 3 items to make this up - 2015/15 , 2031RC30 & 2000H2

        For further information , visit links below:-
        https://www.clipsal.com/Trade/search-results?q=2015/15
        https://www.clipsal.com/Trade/search-results?q=2031RC30
        https://www.clipsal.com/Trade/search-results?q=2000H2
        User-added image

        User-added image
        User-added image

        How can the ATV28 unit be run at a set speed without a speed signal input?

        Issue:   How can the ATV28 unit be run at a set speed without a speed signal input?
         
        Product Line:   ATV28
         
        Environment:  All
         
        Cause:   N/A
         
        Resolution:   
        If a forward or reverse run signal is given to the drive using the logic inputs and no speed signal is present, the drive will run at the LSP (low speed) setting. The factory default low speed setting is 0 Hz. This setting can be changed while the drive is running.


         

        What is EUSERC and what does it mean?

        Issue:
        Acronym meaning

        Product Line:
        Metering Equipment

        Resolution:

        EUSERC is an acronym for Electric Utility Service Equipment Requirements Committee. Formed in 1983, the purpose of the organization is to promote uniform electric service requirements among the member utilities, publish existing utility service requirements for electric service equipment and provide direction for development of future metering technology. There are approximately 80 utilities involved in EUSERC from 12 states. Not all EUSERC member utilities accept all metering devices that meet EUSERC specifications. So, although a device may meet EUSERC specifications, it may not be accepted for use by a specific utility company. Always check with the utility company for approval before using any metering device.


         

        PM700 Series Replacement and End of Commercialization

        Issue
        PM700 End of Commercialization

        Product Line
        PM700, PM700CA, PM700MG, PM700MGCA,PM700P, PM700PCA, PM700PMG, PM700PMGCA, PM710, PM710CA, PM710MG, PM710MGCA, PM750, PM750MG

        Resolution
        All PowerLogic PM700 series meters (PM700, PM700P, PM710 and PM750) were withdrawn from the market place in 2015 following the dates below:

        Asia / Pacific countries: April 30th 2015
        European / Americas / Middle East and Africa countries: August 30th 2015

        All PM700 references will be substituted by the new improved PM5000 references. Suggested substitution below:
         
        Old Product New Product
        PM700, PM700P and PM710 PM51xx
        PM750 PM53xx

        Note:
        • The PM8000 series is also a valid potential replacement, including: PM8240, PM8243, PM8244.
        • Please see links below to knowledge based  articles about the replacement meters types.

        How to configure your TeSys T using SoMove

        The purpose of the FAQ is to show you where are located the different setting parameters when using SoMove configuration tool.
        If you have additional question you can use also “TeSys T help” embedded in SoMove help.
         
        You must always have the latest SoMove version screen copy done in November 2015
         
        Note that the configuration tool (generic name "SoMove") is based on the FDT/DTM architecture, thus is in fact composed of two components
        - The FDT container : SoMove
        - The DTM Device Type Manager : there is one single DTM for both the TeSys U and the TeSys T 

        Most recent versions of each of these components shall be installed on your laptop.
        See attachment for example

        What is the altitude derating for a TeSys D-Line contactor?

        Issue:​
        What is the altitude derating for a TeSys D-Line contactor?

        Product Line:
        Digest 177 Section 18 : Contactors and Starters, IEC

        Environment:
        North American Products

        Resolution:
        The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

        Voltage
        3500m x 0.90
        4000m x 0.80
        4500m x 0.70
        5000m x 0.60

        Current
        3500m x 0.92
        4000m x 0.90
        4500m x 0.88
        5000m x 0.86

        For example, an LC1D80 at 5000 meters:
        - The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
        - The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



         

        Wiser Home Management General Information

        Issue:
        What is the Wiser Home Management System?
        How does Wiser Home Managament Work?

        Product Line:
        Wiser 1.0.  Wiser Generation 1
        sold between 2013 and 2015

        Environment:
        Residential Homes,  United States and Canada

        Cause:
        General Information

        Resolution:

        The Resolution described here is current as of May 2015

        The Wiser system is a network of devices that make residential homes use less energy.  They do not prevent energy loss in the same way that efficient windows, doors, and insulation.  But they can make a home less wasteful of energy.  
         
        The Wiser System consists of 3 types of devices:  Thermostats, Power Monitors, and Load Control Relays.    These devices talk to each other and the Coordinator Gateway via ZigBee radio.  The Coordinator Gateway sends data and receives commands via the internet.   Thus, a home owner can program his thermostats, monitor power usage, and control loads via the web portal or mobile app.
         
        Wiser System can be sold on the the open retail market and it is also distributed through utility companies implementing Demand Energy Response programs.   Wiser Systems that are sold and distributed through utility companies will be connected and react to Demand Energy Events by that utility company.   For example, on a hot summer day when the electric grid is at max capacity, the utility company may command the participating Wiser Systems to adjust their thermostat temperature setpoints up 3 degrees to reduce the HVAC loads and relieve the burden on the power grid.
         
        Wiser Systems sold through retail channels would not be connected to any utility program and would never receive Demand Energy Response commands. 
         
        If one were to install a system today, one would need a Wiser Coordinator to start, EER21200.  Every system must have one of those.  It serves as a hub and communication gateway to the internet.  One could add Power Monitors, Thermostats, and Load Control Devices as he wishes.  Add up to 10 devices to a single Coordinator. 
         
        There are 3 Thermostats for Wiser, EER56000, EER56100, and EER58000. 
         
        There are 2 versions of Power Monitors:  part numbers are WISERJLPM200 and WISERCTPM200.   Both can monitor 200 Amp circuits.  JL can only monitor a single 240V circuit with 2 CTs.    The CT unit can accept 4 CTs.   It can monitor 2 240V circuits, 4 120V circuits, or any combination.   The CT unit was just very recently released so it is not on the Parts List attachment.
         
        There are several devices for switching circuits  on and off.  See the Parts List
         
        I have also attached some marketing materials of Wiser.  Note that they show possible interfaces to Solar Inverters, EV Charging stations and Security Systems.  These are not available at this time. 
         
        Frequently Asked Questions:
         
        Where can I purchase Wiser Components?
        Electrical contractors can purchase through Schneider Electric Dealers such as Graybar, Grainger, CED, and many others.  Retail customers can purchase through HomeDepot.com and Amazon.com
         
        Is there a monthly fee?
        Most features of Wiser are free including Power Monitoring and Thermostat control.  Some features such as Switching of Load Control Devices require a subscription to the Premium Plan
         
        Can I demo or view Wiser System on the web?
        The  web portal is www.wiserenergy.com.  
        You can login to a demo account with Username Wiser320,  Password:  wiser11.    
        There is a youtube playlist showing all aspects of the Wiser System:  https://www.youtube.com/playlist?list=PLv1zq8ADLVVF8suI3lSD8th2XcQ0Vl7dG