2015RDL-WE 2000 Series

Socket Switch Single 10A Red Dolly

Catalogue Number: 2015RDL
2015RDL-WE 2000 Series
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Sustainable offer status
Green Premium product
EU RoHS Directive
Compliant
Mercury free
Yes
RoHS exemption information
Yes
China RoHS Regulation
Product out of China RoHS scope. Substance declaration for your information
Environmental Disclosure
ENVPEP120506EN
Circularity Profile
N/A

Frequently Asked Questions

hide show

Do Clipsal have a 2025 that has red switches instead of white?

Yes, the 2025RDL-WE features a red dolly assembly
For more information on this product please visit the Clipsal web site on the link provided
https://www.clipsal.com/Trade/search-results?q=2025rdl

Do you have a single vertical outlet that is double pole?

Yes,we do have  a single vertical outlets that are double pole. The part numbers are 2015VD-WE and C2015VD-WE.

What is the alternative for the PDL 691RCD10 in red

If it is not in a hospital you could use a PDL 691RCD10 in white and order a red cover as a special.  For a hospital use a Clipsal ML2031VRC10 and Clipsal 2025RD together in a double surround.

Customer asked if the manual transfer switches are available with an interlocked receptacle option?

No


CTA-ID : 2015863

What is the PDL version of the 2015XX?

The PDL version of the 2015XX is a PDL694XXWH.

 

Is there a double pole 15A outlet?

Yes, the part number is a 2015D15

What is part no for 15amp vertical single GPO

PART NO 2015V15

In the 600 Series, is the 691/15 available in RED

Not available, but Clipsal 2015/15 is available in red but it's horizontal.

What is part number for cover to suit C2015D4 metal finish?

The part number for cover to suit is a C2015D4C-3A.

What version of C-Bus Toolkit supports eDLT

C-Bus Toolkit 1.12.7 and above. It is always recommended to be on the latest software available from https://www2.clipsal.com/cis/technical/downloads/c-bus_toolkit

What is the part number of a replacement button cap for an XB4BA21?

Issue:
What is the part number of a replacement button cap for an  XB4BA21?

Product Line:
Harmony Pushbuttons

Environment:
All Products

Cause:
Product selection

Resolution:
Use a ZBA2 black cap or otherwise the black cap from a universal ZBA9 kit


CTA-ID : 2015097

What is the part number for a diode for a CA3KN relay?

Issue:
What is  the part number for a diode for a CA3KN relay?

Product Line:
Tesys Relays

Environment:
All Products

Cause:
Product selection

Resolution:
LA4KC1B or LA4KC1E is the diode and zener diode for the CA3KN relay.


CTA-ID : 2015604

What would be the part number for a C2015D4 brushed aluminium cover

We do not do a Brushed Aluminium Cover for the C2015D4
The closest we could do would be a C2015D4C-3A which is arctic silver.
Also comes in a range of other colours.
please see following link for entire colour range and further documentation.
https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2015D4

Which version of C2015D4 is double pole?

The C2015D4-WE is double pole switching.

What is the part code for a very old PDL Shaver Socket Conversion Plate

The conversion plate is no longer available but you can use the below part numbers for the Clipsal version
2000/3-WE + 2015-WE + 2727-WE + 2031RC30-WE

Is there a red double horizontal socket available without the RCD, Neon, or Circ ID in the Medliec range?

Yes, the 2025, double horizontal socket 250V 10A is available in red. Use the code 2025-RD.
 

Are there double GPO's that are individually wired on each side?

Yes, there are a few GPO's that are individually wired, they are C2016/2, 16/2MF, 2015/2V and 15/2V. In a weather proof option we have the WSC227/1/2

What are the dimensions for the C2015D4 quad outlet?

The dimensions for the C2015D4 are 196mm (w) 75.5 (H) 23mm (D) 

For further information on this product please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2015D4​

 

How do I access the Tools Page in eDLT

Press and hold down the bottom left button, whilst continuing to hold then double press the top right button.
Please note that access to the Tools Page can be disabled using C-Bus Toolkit software

Can a factory-installed provision for a keylock be ordered with an NW breaker?

Issue:
Factory installation of key interlock provisions on NW Masterpact circuit breakers.

Product Line:
Circuit Breakers

Environment:
Products sold and used in the United States

Cause:
Factory installed key interlock on NW Masterpact circuit breakers

Resolution:
It is possible to order "provision-only" for an NW breaker key interlock. The provision is also available as a field-installable kit. See pricing guide for catalog numbers.

CTA-ID : 2015133

Why is the drive not responding to the 4-20mA feedback signal when the Pump Switching Card is installed?

Most common issue is Parameter o19 must be set to the maximum pressure of the sensor in Bars.  Parameter o20 is set to the PI setpoint in Bars.

To get the pressure in Bars, divide the pressure in PSI by 14.504.


CTA-ID : 2015151

What is the difference between the XACA201 and XACA205 pendant stations?

Issue:
What is the difference between the XACA201 and XACA205 pendant stations?

Product Line:
Pendant Stations

Environment:
All products

Resolution:
XACA201 has 1-NO contact on each button. The XACA205 has 1-NO on one button and 1-NC contact on the other button.

Is the CA2KN22G7 DIN rail mountable?

Issue:
Is the CA2KN22G7 DIN rail mountable?
Product Line:
Industrial Relays
Environment:
Tesys K IEC Style Relays
Cause:
Determine how to mount for application.                             
Resolution:                                                                 
Yes. They are made to mount on 35mm DIN3 type mounting rail.
 

Are parts still available for the obsolete CME product line?

Issue:
Old Product Design metering

Product Line:
Commercial Metering Equipement (CME)

Ennvironment:
Repair parts

Cause:
Maintenance

Resolution:
All CME parts are obsolete and no longer available. 


 

What is the ampere rating for dc voltages for the 9001KA contact blocks?

Issue:
DC ampere rating for 9001KA contact blocks

Product Line:
Harmony Push Buttons

Environment:
Harmony 30mm

Cause:
Product Features

Resolution:
2.5A continuous up to moved. (NEMA Q600)

What is the part no for a double powerpoint with a larger space in between to use with power packs?

The part no is 2015H2. It is 2 x single horizontal switched sockets side by side with a single frame.

 

Is there a Brushed Aluminum (BA) cover for a C2015D4

There is no BA cover plate but you can use the 3A (Artic Silver) it is very similar C2015D4C-3A

What is part no for 4 gang powerpoint C2000 series?

Part no is C2015D4

Is there a Brushed Aluminium( BA) cover for the C2015D4?

Brushed Aluminium( BA) covers for C2015D4 are not available. Arctic Silver (3A) is the closest colour match to Brushed Aluminium (BA). Eg C2015D4C-3A
For more information on this range please visit the Clipsal web site on the link provided
https://www.clipsal.com/Trade/search-results?q=c2015d4
 

Do you do the quad outlet C2015D4 in red?

Yes, the part number is C2015D4-RD.

Some of its key features are:

  • 4 Gang switch
  • 10 Amp
  • 250V
  • 2 Pole
  • Horizontal mount
  • Also available in metal finishes
For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2015D4 

What is the replacement part codes for RUMC2AB2 & RUM3CAB2?

References changed in 2015
RUMC2AB2•• becomes RUMC22••
RUM3CAB2•• becomes RUMC32••

the above codes use the same bases:
RUMC22••/ RUMC2AB2•• = RUZC2M
RUMC32••/ RUMC3AB2•• = RUZC3M

What are the part number for a 15 amp outlet with RCD protection?

Not available as 1 unit. Would have to use 2015/15 with 2031VRCD30
For further information , visit links below:-
https://www.clipsal.com/Trade/search-results?q=2015/15
https://www.clipsal.com/Trade/search-results?q=2031VRCD30
User-added image
User-added image

What are the dimensions for 8639 LPA4NA & LNA4NA?

Issue: What are the dimensions for 8639 LPA4NA & LNA4NA?
 
Product Line: 8639 ATS46
 
Environment: 8639 LPA4NA & LNA4NA
 
Cause: N/A
 
Resolution: Theses are Floor mount unit at 34.21 inches wide, 92.68 inches tall, 26.00 inches deep with disconnect handle extended.

The wieght is 850 lbs

This is the same for class 8638 & 8639 Type NI - NQ standard duty and LM - LP heavy duty.


 

What is the ATS48 line voltage operating range?

Issue:
What is the ATS48 line voltage operating range?

Product line:
Altistart 48, ATS48

Environment:
all

Cause:
n/a

Resolution:
The Altistart 48 is suitable for three phase supply voltages that range from 208VAC to 690VAC , 50/60Hz.  The tolerance of the voltage supply is -15% to +10%. 

 

Are replacement contacts available for a CAD32 relay?

Issue:
Contacts need to be replaced in a CAD32** relay.

Product Line:
TeSys D IEC style relays

Environment:
CAD relays

Resolution:
The TeSys D IEC style relays do not offer replacement parts.  Replace entire device.

Will the accessories used for the GV3ME06 through GV3ME63 work with the GV3ME80?

Product Line:
GV3 manual motor starters, IEC

Resolution:
The standard GV3 accessories will work on this device.

What is the difference between 9001SKYP4 and SKYP40?

Issue:
What is the difference between 9001SKYP4 and SKYP40?

Product Line:
Harmony Control Stations

Environment:
All Products

Cause:
Product Features

Resolution:
9001SKYP4 is the enclosure only if customer wishes to order pendant station in components.
9001SKYP40 is the enclosure catalog if customer wishes to order pendant station as completely assembled with operators, contact blocks and legend plates and requires key sheet.


 

What is the lock out device for a 9001BW241?

Issue:
Is the lock out device on 9001BW241 sold separately?

Product Line:
Pushbuttons and Operator Interface

Environment:
9001B Standard Duty Control Stations

Cause:
Product Selection

Resolution:
The lock out is not offered as a separate item. Replace the cover with 9001BWD220 tha has a lockout factory installed on it.

What is the difference between ZB2BZ101 and ZB2BE101?

Issue:
What is the difference between ZB2BZ101 and ZB2BE101?

Product Line:
Push Buttons

Environment:
22mm Push Buttons

Cause:
Product Features

Resolution:
ZB2BZ101 is a ZB2BE101 (normally open contact block) + ZB2BZ009 mounting collar




 

Is there a padlock device for the 9001KR9R?

Issue:
What Padlock Device can be used on the 9001KR9R E-stop Pushbutton?

Product Line:
Harmony Pushbuttons

Environment:
All Products

Resolution:
9001K62, 9001K162
NOTE: These attachments will not work when the operator is supplied with a 2 1/4 inch diameter mushroom.

Important security notification: M340, Quantum, Premium and STB Ethernet communication modules (ICS-ALERT-11-346-01)

Goals and Symptoms

Notification and recommendations concerning security as found in ICS-ALERT-11-346-01
Updated Aug. 20, 2015
This is an update to previous Resolution RES206895.

Causes and Fixes

See Attached document

Attachments

What is the part number for a mounting block for C2015D4?

The mounting block to suit a C2015D4 is C2015D4MB.
PLease see link below for more information.

https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2015D4MB

What is the part number for a Chrome Shadow cover for the C2015D4?

The part number for a Chrome Shadow cover for the C2015D4 is - C2015D4C-3S

For further information, visit the link below:-
https://www.clipsal.com/Trade/search-results?q=C2015D4C-3S
User-added image

What is the part number for a replacement for 15/15/EL30?

There is no direct replacement for this unit. Customer would be able to use 3 items to make this up - 2015/15 , 2031RC30 & 2000H2

For further information , visit links below:-
https://www.clipsal.com/Trade/search-results?q=2015/15
https://www.clipsal.com/Trade/search-results?q=2031RC30
https://www.clipsal.com/Trade/search-results?q=2000H2
User-added image

User-added image
User-added image

How can the ATV28 unit be run at a set speed without a speed signal input?

Issue:   How can the ATV28 unit be run at a set speed without a speed signal input?
 
Product Line:   ATV28
 
Environment:  All
 
Cause:   N/A
 
Resolution:   
If a forward or reverse run signal is given to the drive using the logic inputs and no speed signal is present, the drive will run at the LSP (low speed) setting. The factory default low speed setting is 0 Hz. This setting can be changed while the drive is running.


 

What is EUSERC and what does it mean?

Issue:
Acronym meaning

Product Line:
Metering Equipment

Resolution:

EUSERC is an acronym for Electric Utility Service Equipment Requirements Committee. Formed in 1983, the purpose of the organization is to promote uniform electric service requirements among the member utilities, publish existing utility service requirements for electric service equipment and provide direction for development of future metering technology. There are approximately 80 utilities involved in EUSERC from 12 states. Not all EUSERC member utilities accept all metering devices that meet EUSERC specifications. So, although a device may meet EUSERC specifications, it may not be accepted for use by a specific utility company. Always check with the utility company for approval before using any metering device.


 

Is there a brushed alloy cover for a 4 gang socket avaliable?

No, unfortunately in the quad switch socket outlet in the classic series the brushed alloy cover isnt avaliable. However, we do have a wide range of colours avaliable for the C2015D4 quad switch socket.

For further information on this product and its colour range please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2015D4
 

Is there a solid mounting block for the C2015D4?

Not directly, It can be made up of 2 parts, use a C2015D4MB mounting block and a C2015D4P backing plate to suit.
For more information on this range please visit the Clipsal website on the link provided.
https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2015D4P

PM700 Series Replacement and End of Commercialization

Issue
PM700 End of Commercialization

Product Line
PM700, PM700CA, PM700MG, PM700MGCA,PM700P, PM700PCA, PM700PMG, PM700PMGCA, PM710, PM710CA, PM710MG, PM710MGCA, PM750, PM750MG

Resolution
All PowerLogic PM700 series meters (PM700, PM700P, PM710 and PM750) were withdrawn from the market place in 2015 following the dates below:

Asia / Pacific countries: April 30th 2015
European / Americas / Middle East and Africa countries: August 30th 2015

All PM700 references will be substituted by the new improved PM5000 references. Suggested substitution below:
 
Old Product New Product
PM700, PM700P and PM710 PM51xx
PM750 PM53xx

Note:
  • The PM8000 series is also a valid potential replacement, including: PM8240, PM8243, PM8244.
  • Please see links below to knowledge based  articles about the replacement meters types.

How to configure your TeSys T using SoMove

The purpose of the FAQ is to show you where are located the different setting parameters when using SoMove configuration tool.
If you have additional question you can use also “TeSys T help” embedded in SoMove help.
 
You must always have the latest SoMove version screen copy done in November 2015
 
Note that the configuration tool (generic name "SoMove") is based on the FDT/DTM architecture, thus is in fact composed of two components
- The FDT container : SoMove
- The DTM Device Type Manager : there is one single DTM for both the TeSys U and the TeSys T 

Most recent versions of each of these components shall be installed on your laptop.