Flush SurRound, 1 Gang, Horizontal Mount, Curved Sided, Standard Pattern

Catalogue Number: 2000
surround 2000 ser
SURROUND 2000 SERIES
surround 2000 ser
SURROUND 2000 SERIES
Colour: White Electric
Colour: Per UOM Std.
  • Black 1 PCE
  • Cream 1 PCE
  • Dark Blue 1 PCE
  • Green 1 PCE
  • Red 1 PCE
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Range of product
Series 2000
Product brand
Clipsal
Mounting position
horizontal
Device mounting
flush
Material
plastic
Type of installation
indoor
Surface finish
brilliant
Depth
13 mm
Length
116 mm
Width
76 mm

Documents & downloads

hide show
Filter items
  • All

  • Product Brochures

  • CAD Files and Packs

  • Technical Data Catalogues

  • Product Environmental

Frequently Asked Questions

hide show

What are the part#'s for the Panelmate Plus Modbus Plus Interface Board?

The part #'s for the Panelmate Plus Modbus Plus Interface Boards are:
1) MM-PMMP001C - Panelmate Plus 2000 / 3000 / 4000 Modbus Plus Interface, CE
2) MM-PMMP002C - Panelmate Plus 2000 / 3000 / 4000, Dual MB+ Interface, CE
3) MM-PMMP003C - Panelmate Plus 1000 / 1500 Modbus Plus Interface, CE

What is the frequency of the internal buzzer used in the Magelis XBTGT 2000 to 7000 series HMI terminals?


The buzzer frequency is between 2000Hz and 2600 Hz. (2300Hz typical)


Legacy KB System (APS) Data: RESL192877 V1.0, Originally authored by MiMe on 10/01/2008, Last Edited by MiMe on 10/01/2008
Related ranges: Magelis XBT G

Is Event Notification Solution 6.4 /Active Pager Module 6.4 (ENS 6.4, APM 6.4) compatible with SQL 2000?

ENS 6.4 is only supported with SQL 2005 and SQL 2008 instances.
During the install, SQL 2000 instances can be chosen, but the install will not complete if a SQL 2000 instance is selected.


Legacy KB System (APS) Data: RESL206608 V1.0, Originally authored by MaTh on 11/09/2011, Last Edited by MaTh on 11/09/2011
Related ranges: Paging Module, SMS Add-on

Does OFS V3.50 supports Windows 8

Yes, OPC v3.5 Factory Server is supported in Windows 8, Server 2012, Windows 7, Server 2008 R2, Vista, XP, 2000, and Server 200. OFS must not be installed on virtual machines.

What is the default password for PowerLogic meters?

Product Lines
CM4000 / CM4
CM3000 / CM3
CM2000 / CM2
PM800 / PM8
PM700 / PM7
PM600 / PM6
PM200 / PM2
EM3500
PM5000 Series
PM8000

Environment
On-board Password

Resolution
The default password is 0000

Sepam EcoFit offer

Schneider Electric offers a retrofit solution for converting Sepam 2000's to the new Sepam 1000+ relays.
ECOFIT S2000 Leaflet - SERED111087EN.pdfECOFIT S2000 Leaflet - SERED111087EN.pdfECOFIT SEPAM 2000 Customer Presentation Rev1a.pptECOFIT SEPAM 2000 Customer Presentation Rev1a.ppt

Can you get a double power point with 2 USB ports?

No, unfortunately this part is unabaliable. However, there is a single power point with 2 USB ports avaliable. This is avaliable in two diffrent styles, 2000 Series or the Classic 2000 Series. The part numbers are (Classic 2000) C2015USB2C and (2000 Series) 2015USB2C.
Some of there key features are:
  • Twin 30USBCM USB Chargers
  • Surge, over-current and over-temperature protection
  • Cable compensation for optimised charging
  • Meets BC1.2 USB Charging Standard
  • Meets Class V Energy Efficiency in standby
  • Certified to all relevant safety and EMC requirements for Australia

For further information please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=2015USB2C
                                              Or https://www.clipsal.com/Trade/Products/ProductDetail?catno=C2015USB2C

 
 
 

 

What is the wattage rating for Clipsal 501ES

It is 200w for white ones

Can 2000 series and C2000 series, IP66 range of switches be used outdoors?

Clipsal IP66 2000 Series and C2000 Classic series switches are hardwearing, UV stabilised, polycarbonate surface and suitable for a wide variety of outdoor areas, such as carports and pergolas.
For further information, please visit https://updates.clipsal.com/ClipsalOnline/Files/Brochures/A0000083.pdf

Is it Possible to Upgrade a 1600A NW16 Breaker to a 2000A NW20 by Changing the Sensor Plug.

No. It is not possible. As per the attached document the NW16 have sensor rating only from 800 - 1600A, So a 2000A Sensor Plug is not suitable for NW16 Breaker. So it can not be changed. 

What version of SQL Server is used with the different versions of ION Enterprise?

ION Enterprise 3.0 MSDE 1.0 (SQL Server 7.0)
ION Enterprise 4.0 MSDE 1.0 (SQL Server 7.0)

ION Enterprise 4.5 MSDE 1.0 (SQL Server 7.0)

ION Enterprise 5.0 MSDE 2000 (SQL Server 2000)

ION Enterprise 5.5 MSDE 2000 (SQL Server 2000)

NOTE: It is possible to use ION Enterprise 5.5 Service Pack 2 with SQL Server 2005, but some modifications are required. See KB articles 12704, 12708 and 12823 for detailed information.

ION Enterprise 5.6 SQL 2005 Express (SQL Server 2005)
NOTE: ION Enterprise 5.6 will use an existing MSDE 2000 instance, but will install SQL Express on new systems if there is no pre-existing SQL Server instance.
ION Enterprise 6.0 SQL 2005 Express with Reporting Services SP3 (SQL Server 2005 SP3 with Reporting Services)
NOTES: The ION Enterprise 6.0 installer will upgrade an existing MSDE 2000 instance to SQL Server 2005 Express with Reporting Services. ION Enterprise 6.0 does not support SQL Server 2000. It also does not support SQL Server 2008

  • Original article#16492

    Public

    All content © 1992-2009 Schneider Electric


Legacy KB System (APS) Data: RESL188782 V3.0, Originally authored by KBAdPM on 11/02/2007, Last Edited by JaMc on 10/15/2009
Related ranges: ION Enterprise V5.5, ION Enterprise V5.0, ION Enterprise V4.5, ION Enterprise V4.0

What is the Pin out detail for the Modbus programming cable 110 XCA 20 3000?

The pin out details of the Modbus programming cable 110 XCA 20300 is as shown in the attached.

 

Show More