sock swt sing 10a skirt e/sw

Single Switch Socket Outlet, 250V, 10A, Skirt Mount, Removable Extra Switch

Catalogue Number: 16X
sock swt sing 10a skirt e/sw
Colour: White Electric
Colour: Per UOM Std.
  • White Electric 1 PCE
Added to cart

Specifications

hide show
Product brand
Clipsal
Range of product
Standard Series
Control type
ON/OFF button
Number of gangs
1 gang
Pin number
3
Number of power socket outlets
1
Actuator
  • rocker
  • switch
    • Mounting position
      horizontal
      Fixing mode
      by screws
      Local signalling
      without light indicator
      Material
      plastic
      Surface finish
      glossy
      [Ue] rated operational voltage
      250 V AC
      [In] rated current
      10 A
      Depth
      14 mm
      Length
      98 mm
      Width
      45 mm
      Fixing center
      78 mm
      Standards
    • AS/NZS 3100
    • AS/NZS 3112
    • AS/NZS 3133:approval number S/1
      • Sustainable offer status
        Green Premium product
        EU RoHS Directive
        Compliant
        Mercury free
        Yes
        RoHS exemption information
        Yes
        China RoHS Regulation
        Product out of China RoHS scope. Substance declaration for your information
        Environmental Disclosure
        ENVPEP120506EN

        Documents & downloads

        hide show
        Filter items
        • All

        • Product Brochures

        • Technical Data Catalogues

        • Specifications

        Frequently Asked Questions

        hide show

        What does the 16AX mean on the PDL 681MT16WH

         It means it has a 16A fluro rating

        What are the Vijeo Designer v6.2 Runtime specifications/limitations?

        Issue:
        What are the Vijeo Designer v6.2 Runtime specifications/limitations?

        Product Line:
        Vijeo Designer, XBTGC/GK/GT, HMIGK/GTO/GTU/STO/STU, iPC, Panel PC, Box PC

        Resolution:
        Below are the Runtime specifications for Vijeo Designer v6.2.

        Run-Time Specifications

        • Use the following statistics as only a guideline for creating your own applications. Some applications may not be able to run despite remaining below these documented numbers because of memory limitations. To make sure your application will run correctly, check the memory requirement for each panel and operation, and compare these requirements with your target machine. For details, see Section 25.3.3, Checking Memory Usage. Always test your application thoroughly before running it in a production environment.
        • The following statistics were obtained by testing each individually on factory machines. These numbers will vary depending on the operating environment, the complexity of the application, the CPU load, and the amount of memory available on the target machine. Some of these performance numbers can be enhanced with upgraded memory, CF Cards/SD Cards, and hard disks.
        Panels
        Number of panels/popup windows (limit) The number of panels that can be created in a project depends on the amount of flash memory available on your target machine and on the size of  each panel. For example, you can have a project on an XBTGT6330 target that contains 100 panels.
        As the number of panels for your project increases, memory consumption also increases.
        Number of objects on a panel (recommended) The number of objects that can be placed on a panel depends on the target machine's panel height and width. For example, you can have a project on an XBTGT6330 target that contains 200 objects per panel.
        As the number of objects placed on a panel increases, memory consumption also increases.
        Popup windows (limit) Number of popup windows that can be displayed at run time: maximum of 3, which includes the popup keypad.
        Large Toolchest parts On some targets, large parts placed on a panel may cause a wait time to occur when changing panels. For example, on an XBTGC 2230U, switching from one panel to another panel with a Web Browser took several seconds.
        Actions
        Maximum number of actions 100
        Scripts
        Maximum length of each script (recommended)
        For other script recommendations, see Section 18.3.4, Key Points.
        50 lines
        Error Logging
        Number of run-time events stored 100
        Alarms and Events
        Number of Alarm Groups and Event Groups in a Target (limit) 32 max.
        Number of Alarm Categories and Remote Categories in a Target (limit) 32 max.
        Number of event records in an event group (limit) The number of event records you can store in each event group is 10,000 max. Events are recorded in both History and Log, which results in having two event records for each event that occurs. For example, if you set 10,000 as the maximum number of total records, you can only store 5000 events.
        Number of alarms in alarm groups (limit) The number of Log and History alarm records you can store in each alarm group is 10,000 max.
        In the Alarms node, when Backup Alarm Group is set to No, you can store up to 80,000 total Log and History alarms in a target's alarm groups.
        When Backup Alarm Group is Yes, the number of alarms is limited by the space available on SRAM.
        Number of alarms in an alarm category (limit) and remote category 60,000
        Alarm Backup
        The size required by each alarm message depends on the alarm type.
        Active: 20 bytes per record
        History: 24 bytes per record
        Log: 16 bytes per record
        SRAM Capacity (Backup) is different for each target machine type.
        128 to 512 KB (Depends on model. Refer to your hardware manual.)
        For information about how much SRAM is required by your project, see Section 4.5.1, Target Properties.
        E-mail
        Number of attachments per e-mail 1 max.
        Maximum size of file attachment 10 MB
        Link Objects
        Maximum number of definition objects (per Target node) 100
        Maximum of folder levels in the folder structure for definition objects (per Target node) 5
        Files
        Number of text files (limit) 200 max.
        Text file size (recommended) 50KB max.
        Number of video files (limit) 200 max.
        Number of sound files (limit) HMIG5U / HMIG5U2 / iPC / XBTGTW Series HMIG3U / XBTGC / XBTGT / XBTGH / HMIGTO / HMISTO / HMISTU / HMISCU / HMIGK Series XBTGK Series
        1,500 200 200
        Languages
        Number of user languages you can create (allowed) 15 max.
        Variables
        Number of variables per panel (limit) HMIG5U / HMIG5U2 / iPC Series All other target types
        Maximum 2500 variables per panel Maximum 800 variables per panel.
        Number of variables per target (limit) HMIG5U / HMIG5U2 / iPC / XBTGTW Series HMIG3U / XBTGC / XBTGT / XBTGH / HMIGTO / HMISTO / HMISTU / HMISCU / HMIGK Series XBTGK Series
        12000 max. 8000 max. 8000 max.
        • For iPCs, if persistent variables such as alarm variables and data logging variables are used, a maximum of 8000 variables can be supported for each iPC target.
        Number of variables you can share (recommended) HMIG5U / HMIG5U2 / iPC / XBTGTW Series HMIG3U / XBTGC / XBTGT / XBTGH / HMIGTO / HMISTO / HMISTU / HMISCU / HMIGK Series XBTGK Series
        400 300 300
        • The Maximum Number of Shared Variables is the recommended maximum number of variables that is shared at any one time NOT the maximum number of Sharing-enabled (Read-only or Read/Write) variables. In other words, the number of variables that you set to Read-Only or Read/Write has no limits; only the number of variables that are accessed by other targets is limited. Performance may become an issue if you exceed the recommended maximum.
        Security
        Number of security groups per target 20 max.
        Number of users per security group 100 max.
        Number of users per target 100 max.
        Number of users per Vijeo Designer project 200 max.
        Driver Restrictions on Windows Target Machines
        Biometric Switch The Biometric Switch's USB driver currently does not support Windows target machines running on embedded Windows operating systems, including Windows XP Embedded and Windows Embedded 7.
        Drivers not supported on target machines that run Windows operating systems The following drivers are not supported on Windows operating systems, and therefore Windows target machines cannot connect to physical equipment using these drivers. Simulation in Buildtime is also not supported.
        Schneider Electric:
        • Modbus TCP/IP USB
        • Modbus Plus
        • Modbus Slave RTU
        • FIPIO
        • FIPWAY
        Siemens AG:
        • MPI/PPI
        Rockwell Automation:
        • DH485
        Data Logging
        Number of Data Logging Groups in a target (limit) 80
        Maximum number of variables being logged in a target HMIG5U / HMIG5U2 / iPC / XBTGTW Series HMIG3U / XBTGT1005 / XBTGT2000 and higher / XBTGC / XBTGK / HMIGTO / HMISCU / HMIGK Series HMISTO / HMISTU Series XBTGH Series
        250 variables max. 100 variables max. 60 variables max. 80 variables max.
        Table Resources
        Maximum number of table resources in a tablet/smartphone project 10
        Maximum number of states in a table resource 255
        Resource Library
        Maximum number of Text, Color, Image, Font Resources in a project (limit) 256
        Maximum size of an image file used in an image resource 1920x1080
        Forms Printing
        Number of forms you can create for each user application (limit) 50 max.
        Maximum number of objects on one form (recommended) 2000
        Communication
        Number of equipment nodes (limit) HMIG5U / HMIG5U2 / iPC / XBTGTW Series HMIG3U / XBTGC / XBTGT / XBTGH / HMIGTO / HMISTO / HMISTU / HMISCU / HMIGK Series XBTGK Series
        80 max. 48 max. 48 max.
        Number of scan groups per equipment (limit) 20 max. per equipment node
        Number of Maximum Share Connections (limit) HMIG5U / HMIG5U2 / iPC / XBTGTW Series HMIG3U / XBTGC / XBTGT / XBTGH / HMIGTO / HMISTU / HMIGK / HMISCU Series XBTGK Series
        32 8 8
        • The maximum number of shared connections includes:
        • Remote targets in target-to-target sharing
        • Web Gate
        • Vijeo Design'Air Plus mobile devices
        • Remote alarm access from other targets
        • Intelligent Data Services (IDS) tool access
        Recipe
        Total number of recipe groups (standard recipe group or Parison Recipe Group) per target 32 max.
        Number of recipes in a recipe group (limit) 256 max.
        Number of ingredients in each recipe (limit) for a standard recipe group 1024 max.
        Number of ingredients in each recipe (limit) for a Parison Recipe Group 64 min.
        400 max.
         
        The user application you create in the Editor is restricted by target machine run-time specifications. The following table lists the memory capacity of available target machines. DRAM memory affects how much information you can display on the panel at one time. Internal Memory affects the total size of your application. SRAM memory affects how much information you can store between run-time sessions.
        If you are using a tablet/smartphone, the memory capacity depends on the model. See the manufacturer's specifications for more information.
         
        Target Machine Memory (DRAM) Storage Media / Internal Memory (Flash Memory) Memory (SRAM)
        Magelis iPC Compact MPC KT52 256 or 512 MB N.A. 2 MB (Simulated)
        Compact MPC KT22 512 or 1024 MB N.A. 2 MB (Simulated)
        Compact MPC KT12 512 or 1024 MB N.A. 512 KB
        Compact MPC KT55xx2 512, 1024, or 2048 MB N.A. 512 KB
        Compact MPC KT22xxx20 512 MB N.A. 512 KB
        Compact PC Box MPC KN02 512 MB N.A. 512 KB
        Smart MPC ST52 256, 512, or 1024 MB N.A. 2 MB (Simulated)
        Smart MPC ST21 256, 512, or 1024 MB N.A. 2 MB (Simulated)
        Smart MPC ST11 256 or 512 MB N.A. 512 KB
        Smart/Smart+ MPC ST52xx2/HMI PSx7 256, 512, or 1024 MB N.A. 512 KB
        Smart Box MPC SN01 256 MB N.A. 512 KB
        Smart MPC ST21xxx20 512 MB N.A. 512 KB
        Flex PC Box PTX MPC02 512 MB N.A. 2 MB (Simulated)
        Flex PC Box PTX MPC05 512 MB N.A. 2 MB (Simulated)
        Box Performance HMIBPxxx2 2-8 GB Storage media 512 KB
        Box Performance HMIBPxxx5 2-8 GB Storage media 512 KB
        Box Universal HMIBUxxx1 1-3 GB Storage media 512 KB
        Box Universal HMIBUxxx2 1-3 GB Storage media 512 KB
        HMIGTW5354/Panel W HMIPWC5 1-2 GB Storage media 512 KB
        HMIGTW7354x/Panel Optimum HMI PWC7/PVC7 1-2 GB Storage media 512 KB
        Panel Performance HMIPPx6 4 GB DDR3 (in 1 slot) Storage media 2 MB (Simulated) or Interface Option ports (IF and IF2)
        Panel Performance HMI PPx7/PRx7 2-8 GB Storage media 512 KB
        Panel Performance HMIPPx9 2-8 GB Storage media 512 KB
        Panel Universal HMIPUx6 2 GB DDR3 (in 1 slot) Storage media 2 MB (Simulated) or Interface Option ports (IF and IF2)
        Panel Universal HMI PUx7/PTx7 1-3 GB Storage media 512 KB
        Panel Universal HMIPUx9 1-3 GB Storage media 512 KB
        XBTGTW450 512 MB N.A. 2 MB (Simulated)
        XBTGTW652 256, 512, or 1024 MB N.A. 2 MB (Simulated)
        XBTGTW750/HMIGTW7353 512 MB N.A. 2 MB (Simulated)
        Rack PC Optimized HMIRSO/HMIRXO 2 GB Storage media Use Internal Flash to simulate SRAM.
        Rack PC Universal HMIRSU 4 GB Storage media Use Internal Flash to simulate SRAM.
        Rack PC Performance HMIRSP 4 GB Storage media Use Internal Flash to simulate SRAM.
        S-BOX PC Optimized HMIBSO 2 GB Storage media Use Internal Flash to simulate SRAM.
        S-BOX PC Universal HMIBSU 4 GB Storage media Use Internal Flash to simulate SRAM.
        S-Panel Performance HMIPSPx7 8 GB Storage media 2 MB (Simulated) or Interface Option ports (IF and IF2)
        S-Panel Performance HMIPSPx9 8 GB Storage media 2 MB (Simulated) or Interface Option ports (IF and IF2)
        Enclosed PC Performance HMIPEPx9 8 GB Storage media 2 MB (Simulated)
        S-Panel Optimized HMIPSOx5 4 GB Storage media 2 MB (Simulated) or Interface Option ports (IF and IF2)
        S-Panel Optimized HMIPSOx7 4 GB Storage media 2 MB (Simulated) or Interface Option ports (IF and IF2)
        Box Universal HMIBMU 4 GB Storage media 512 KB
        Performance HMIBMP 8 GB Storage media 512 KB
        Magelis HMIGTO Series HMIGTO1300 128 MB 64 MB 128 KB
        HMIGTO1310 128 MB 96 MB 512 KB
        HMIGTO2300 128 MB 64 MB 128 KB
        HMIGTO2310 128 MB 96 MB 512 KB
        HMIGTO2315 128 MB 96 MB 512 KB
        HMIGTO3510 128 MB 96 MB 128 KB
        HMIGTO4310 128 MB 96 MB 512 KB
        HMIGTO5310 128 MB 96 MB 512 KB
        HMIGTO5315 128 MB 96 MB 512 KB
        HMIGTO6310 128 MB 96 MB 512 KB
        HMIGTO6315 128 MB 96 MB 512 KB
        Magelis HMIGTU Series HMIG3U 256 MB 1 GB 512 KB
        HMIG5U 2 GB 16 GB 512 KB
        HMIG5U2 2 GB 16 GB 512 KB
        Magelis HMISCU Series HMISAC (HMIS65/S85) 128 MB 128 MB 128 KB
        HMISBC (HMIS65/S85) 128 MB 128 MB 128 KB
        Magelis HMISTO Series HMISTO501 32 MB 16 MB 128 KB (Simulated)
        HMISTO511 32 MB 16 MB 128 KB (Simulated)
        HMISTO512 32 MB 16 MB 128 KB (Simulated)
        HMISTO531 32 MB 16 MB 128 KB (Simulated)
        HMISTO532 32 MB 16 MB 128 KB (Simulated)
        Magelis HMISTU Series HMISTU655 32 MB 16 MB 64 KB
        HMISTU855 32 MB 16 MB 64 KB
        HMIS5T 64 MB 32 MB 64 KB
        Magelis XBTGT Series XBTGT7340 64 MB 32 MB 512 KB
        XBTGT6340 64 MB 32 MB 512 KB
        XBTGT6330 32 MB 32 MB 512 KB
        XBTGT5430 32 or 64 MB*1 32 MB 512 KB
        XBTGT5340 64 MB 32 MB 512 KB
        XBTGT5330 32 MB 32 MB 512 KB
        XBTGT5230 32 MB 32 MB 512 KB
        XBTGT4340 64 MB 32 MB 512 KB
        XBTGT4330 32 MB 32 MB 512 KB
        XBTGT4230 32 MB 32 MB 512 KB
        XBTGT2930 64 MB 16 MB 512 KB
        XBTGT2430 64 MB 32 MB 512 KB
        XBTGT2330 32 MB 16 MB 512 KB
        XBTGT2220 32 MB 16 MB 512 KB
        XBTGT2130 32 MB 16 MB 512 KB
        XBTGT2120 32 MB 16 MB 512 KB
        XBTGT2110 32 MB 16 MB 128 KB
        XBTGT1335 32 MB 32 MB 128 KB
        XBTGT1135 32 MB 32 MB 128 KB
        XBTGT1105 32 MB 32 MB 128 KB
        Magelis XBTGC Series XBTGC1100T 32 MB 16 MB 512 KB
        XBTGC1100U 32 MB 16 MB 512 KB
        XBTGC2120T 32 MB 16 MB 512 KB
        XBTGC2120U 32 MB 16 MB 512 KB
        XBTGC2230T 32 MB 16 MB 512 KB
        XBTGC2230U 32 MB 16 MB 512 KB
        XBTGC2330T 32 MB 16 MB 512 KB
        XBTGC2330U 32 MB 16 MB 512 KB
        Magelis XBTGH Series XBTGH2460 64 MB 32 MB 512 KB
        Magelis XBTGK Series XBTGK2120 32 MB 16 MB 512 KB
        XBTGK2330 32 MB 16 MB 512 KB
        XBTGK5330 32 MB 32 MB 512 KB
        Magelis HMIGK Series HMIGK2310 128 MB 96 MB 512 KB
        HMIGK5310 128 MB 96 MB 512 KB
         
        *1 The XBTGT5430 model comes in two versions that differ in their DRAM size (32 MB or 64 MB). To determine the version of the XBTGT5430, look for the following serial numbers on the manufacturer's label on your target machine:  
        • 32 MB: PV: 01, RL: 00, SV: 1.0
        • 64 MB: PV: 01, RL: 01, SV: 1.1
        In Vijeo Designer when you select XBTGT5430 as a target machine, by default it is set to the 64 MB version. No additional memory check is performed for the 32 MB version. Make sure your application does not exceed the amount of DRAM available on your target machine. To find out the amount of memory available on a target machine, see Section 26.4.6, Displaying Memory.
         

        How many socket outlets can be protected by a RCD or LIOM?

        To meet the requirements of the AS3003 wiring rules the number of sockets connected to a LPD device is associated with the area of installation.

        Cardiac Protected Areas
         
        • Connected to a LIOM 12x socket outlets (multiple patient locations).
        • Connected to a RCD 12x sockets (one patient location).
         
        Body Protected Areas
         
        • Connected to a LIOM (in accordance with AS3000 rules & multiple patient locations.
        • Connected to a RCD 12x sockets (multiple patient locations).

        Is the extra switch in the 15X removable?

        Yes, the extra switch in the 15X is removable. Any 230v rated 30 series mec will fit in it's place.

         

        Are there system words in the M340 that indicate IO health?

        System words 160 through 167 (%SW160 - %SW167) provide health status of M340 racks 0 through 7. 0 indicates an IO fault. 1 indicates correct operation of the IO module.


        What is the part code for a Clipsal Mech with 16ax rating

        The part code is 30USM

        Will the extended memory (6X registers) be saved during a power failure?

        The extended memory (6X register) values are stored in state ram. These values will be saved during a power failure as long as a backup battery is installed, and the battery is good.


        Legacy KB System (APS) Data: RESL164524 V1.0, Originally authored by on , Last Edited by on
        Related ranges: Modicon Momentum

        What is the difference between the S6X and Y suffix on the ATV61 drives?

        Issue:
        What is the difference between the S6X and Y suffix on the ATV61 drives?

        Product Line:
        Alitvar ATV61

        Environment:
        All

        Cause:
        Input line voltage ratings

        Resolution:
        S6X suffix is 500 to 600VAC only
        Y suffix is 575 to 690VAC only

        Cannot Launch to Private Devices from StruxureWare Data Center Expert UI Installed on Linux

         

        Issue
        The StruxureWare Data Center Expert client cannot launch to devices on the private LAN when it is installed on Linux with the network proxy configured.

        Product Line
        StruxureWare Data Center Expert

        Environment
        StruxureWare Data Center Expert user interface (any version)
        Linux

        Cause
        Linux private device launch does not work if the DCE Linux Client has a network proxy enabled.

        Resolution
        Add the DCE server IP address to the Linux client network proxy ignore list, or disable the proxy.

         

        What is the part number of the mounting block to suit 31/3VX, 162 x 115mm blank switch plate?

        Unfortunately we do not have a mounting block  to suit 31/3VX, large format blank switch plate.

        Is there a replacement for 4RCBE116/30Q Quicklag 16A RCBO?

        Unfortunately not,  we do not have a replacement for 4RCBE116/30Q Quicklag 16A RCBO.

        Can a PDL 955RW handle 15A

        Yes, it is rated up to 16A

        What is the amperage for a PDL 626VC2

         It is 16A

        What does 20A/16AX stand for Saturn 60PBL

        It means  20A incandesent, 16A fluro

        How can you convert LV429550 to 160 amps?

        What is the part number for a Schneider, 60 pole, indoor DB with 160 amp main switch?

        The part number for a Schneider, 60 pole, indoor DB with 160 amp main switch is an MB260E31.

        What is the part number of the mounting block to suit the skirting mount, single outlet 16?

        The part number of the mounting block to suit the skirting mount, single outlet 16 is 47.
        For further details, please refer to the below link:
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=16
        https://www.clipsal.com/Trade/Products/ProductDetail?catno=47

        User-added image
        User-added image

        AutoCAD drawings for Micom 12x relay

        Below are the drawings for the Micom P12x relay.
        GN0047-1-case 20TE.dwgP12x--518326101-1.pdf


        What is the code for a 600 series dimmer that has a minimum Load of 16W

        Use a PDL654PBM - Push Button Universal Dimmer Module.
        This has a minimum load of 10W

        Can the 30USM be used for Fluro loads?

        Yes , it is rated to 16AX for fluro based loads.

        User name and password lengths for InfraStruXure Central and Netbotz appliances for an SNMP version 3 inform.

        Issue:

        User name and password lengths for InfraStruXure Central and Netbotz appliances for an SNMP version 3 inform.

        Product Line:

        NetBotz
        InfraStruxure Central

        Environment:

        Netbotz SNMP v3

        Cause:

        SNMP version 3 requirements

        Resolution:

        v3 informs only work under certain circumstances.

        md5/des user/password must be 8-15 characters
        md5/aes user/password must be 8-15 characters
        sh1/aes user/password must be 16+ characters
        sh1/des user/password must be 16+ characters

        for md5 the user name and password only work if they are between 8-15 characters.
        for sh1 the user name and password only work if they are >16 characters.

        What does the 16A & 6AX mean on the 600RM?

        It means the relay module can switch a load of up to 16A resistive or a 6A fluorescent load.

        What is the fluoro rating for a 600 Series mech

        The rating is 16A

        Do PDL do a relay mech

        Yes, it is a PDL 600RM with a 16A resistive rating

        Needs a Power board for ATV71HC11N4

        Issue:
        What is the part number for the ATV71HC11N4 and ATV61HC13N4 power boards?

        Product line:
        ATV71 and ATV61

        Environment:
        All models, all serial numbers

        Cause:
        Power board not functional

        Resolution:
        The Power board for these drive is VX5A1HC1113.

        ATV71 or ATV61: What causes the drive to show a PRF fault code?

        Issue:
        ATV71 or ATV61:  What causes the drive to show a PRF fault code?

        Product line:
         ATV71 ATV61

        Environment:
        All models, all serial numbers 

        Cause:
        This fault is displayed when internal diagnostics determines that the drive has lost its ability to detect when power is removed from the PWR terminal..

        Resolution:

        This is a Power removal fault. Suggest to first measure PRA to 0v and make sure there is 24v present. Could also go to menu 1.2 and go  to the Logic input map: Check the PR - should be high. Could also power down the drive and remove the terminal card ( where all the I/O wires are) and check Sw 1- should be up ( in the source position).
         Cycle power on the VFD to reset the fault.  This fault is not related to an activation of the safety function.
        This fault could be due to damage on the drive.  Repeated faults will require repairing the drive by replacement of the control board and/or power board. Consider returning the VFD for repair.

        What is the purpose of MBP_MSTR FC 16?

        Unity Pro XL V6.0 introduced MBP_MSTR FC 16. This function code allows the user to change the log in status of an ethernet port. In cases where you are unable to connect to a Quantum PLC because the ethernet port is seen as " Already logged in" this FC will prove useful. MBP_MSTR FC 16 will allow you to change the port status to "logged off" and allow the Unity user to log in.
        This would be preferable to using FC 10 (Reset Option module) or performing a power cycle of the PLC.
        There are minimum requirements that the user must meet in order to use MBP_MSTR FC 16. 140NOE77101 minimum firmware version....4.9
        140NOE77111 minimum firmware version....5.0
        140CPU65x xx minimum copro firmware version 3.5


        Legacy KB System (APS) Data: RESL207500 V1.0, Originally authored by DaSo on 02/24/2012, Last Edited by DaSo on 02/24/2012
        Related ranges: Unity Pro - SoCollaborative software

        What is the part number for the 48 Poles IP42 Metal Distribution Board with 160 Amps Main Switch?

        The part number for the 48 Poles IP42 Metal Distribution Board with 160 Amps Main Switch is "MB248D31"


         

        What is the part number for the 4 Pole NSX160H Breaker with 160 Amps Micrologic 2.2 Trip Unit?

        The part number for the 4 Pole NSX160H Breaker with 160 Amps Micrologic 2.2 Trip Unit is "LV430800"

        https://www.schneider-electric.com.au/en/search/LV430800

         

        What is the maximum motor cable length for an ATV312?

        Issue:
        What is the maximum cable distance from an ATV312 drive to the motor?

        Product line:
        ATV312, Altivar 312, ATV320, Altivar 320

        Environment:
        All models

        Cause:
        n/a

        Resolution:
        The ATV312 shows that an output filter or choke is required for any cable distance between the drive and motor exceeding 164 feet (50 meters).  Above 164 feet, there is a change with shielded vs non-shielded.

        Shielded cables
        From 164 feet to 330 feet (100 meters) you can use the LR filter cell or a motor choke.

        Unshielded cables
        From 164 feet to 660 feet (200 meters) you can use the LR filter cell or a motor choke.
         

        What is the part code for INS switch with an escutcheon for the INS100

        No there is no escutcheon for the INS40 - 160 range

        What is the difference between the 8020SCP423 and 8020SCP424 SY/MAX controllers?

        The only difference between the 8020SCP423 and 8020SCP424 SY/MAX controllers is the size of their user memory. The 8020SCP423 has 8K of RAM. The 8020SCP424 has 16K of RAM.

        With led strip light - how many lengths can be run off one driver ?

        As per the catalogue  lsth050wh is supplied with a 16W driver. The LED strip kit has 4.8W/m. So theoretically when the strips are connected in series, 3.3 metres can be run off a driver.
         

        What is the code for Arctic Silver Caps?

        Standard Active Silver Caps are not able to be purchased on their own. The only caps available for the range is the labelled cap pack which also comes with 10x blank Cat's Eye Caps. The part number for the Cap pack is 60PBC-3A.
         

        APC by Schneider Electric - APC Surge Product Recall

        Issue:

        This recall involves APC 7 and 8 series SurgeArrest surge protectors manufactured before 2003. The model and serial numbers are located on a label on the bottom of the surge protector. The two numbers that follow the first letter or letters in the serial number sequence indicate the year of manufacture.

        APC and the words Personal, Professional, Performance or Network are printed on the surge protectors. 

        The unit is included in the recall ONLY if the numbers are 93, 94, 95, 96, 97, 98, 99, 00, 01 or 02.


        Product Line:

        APC SurgeArrest; The following model numbers are included in this recall.
         

        7 Series model numbers

        8 Series model numbers

        NET7   

        NET8   

        NET7T

        NET8N

        NET7T-C

        PER8T           

        PER7  

        PER8TR

        PER7C

        PER8TR-CN

        PER7T

        PER8TVR

        PER7T-CO

        PER8XTV

        PER7T-U

        PRF8T2

        PER7TX137

        PRF8TT

        PER7-U

        PRO8 

        PER7X148

        PRO8T2

        PRF7  

        PRO8T2C

        PRF7T

        PRO8T2MP12

        PRO7

        PRO8T2MP12B        

        PRO7C

        PRO8TV

        PRO7T

         

        PRO7TX183

         

         

        Resolution:

        Contact Schneider Electric for Replacement

        Schneider Electric IT Corp., toll-free at (888) 437-4007 from 8 a.m. to 5 p.m. ET Monday through Friday, or online at https://recall.apc.com, or www.apc.com and click on the Recall link to submit a claim and obtain more information.

        Further Details: CPSC

        What are the Parts required to make up an NSX250F Breaker with Micrologic 2.2 Trip Unit 160 Amps?

        We can make it up with following two items:

        Part number LV431403 - NSX250F Basic Frame
        Part number LV430470 - Micrologic 2.2 Trip Unit 160 Amps

         

        What is the part number for Switchboard with 160 amp main switch and 36 pole?

        Configuring PowerChute Business Edition versions 10.0 and above for use with the Windows SNMP Agent

        Issue:
        How to configure Windows to use PowerChute Business Edition SNMP in conjunction with Windows SNMP and SNMP Trap Services.

        Product Line:
        PowerChute Business Edition versions 10.0 and above

        NOTE: PowerChute Business Edition versions 9.2.1 and below use the Windows SNMP service, see FA159596 for more details.

        Environment: 
        All supported Windows operating systems

        Cause:
        Informational

        Solution:

        Windows SNMP Setup

         
        1. Open “Programs and Features” by clicking the Start button, selecting “Windows System” > “Control Panel” and then clicking “Programs and Features”. From within “Programs and Features”, select “Turn Windows Features On or Off”:


        Alternatively, you can directly access the Windows features dialog box by clicking on the Start button and typing “Turn Windows Features On or Off”.
        1. Scroll down and enable “Simple Network Management Protocol (SNMP)”:


        PowerChute Business Edition Setup
        1. Install PowerChute Business Edition if necessary.
        2. Enable SNMP v1 and/or v3 from the SNMP Settings screen if necessary.
        3. In the “Miscellaneous” section, update the Discovery Port from 161 to a free port e.g. 163 (161 and 162 are the well-known SNMP ports). If you do not make this change, you will see the error below. Click Apply to save your changes.

        Remove conflicting Registry entry
        1. Click on the Start button, type regedit to launch the system registry editor and delete the following registry Key:
        [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\SNMP\Parameters\ExtensionAgents]
        "1"="SOFTWARE\APC\PowerChute Business Edition\agent\snmp"
         
        1. Open Control Panel - Administrative Tools - Services and restart the PowerChute Windows Service
        APC PBE Agent Service
         
        1. Restart the Windows Services
        SNMP Service
        SNMP Trap
        1. Create a new PowerChute Agent IP/Port (Port from Step 5) mapping entry in your NMS.
        2. Test your changes.
        You should be able to send traps from PCBE Agent to NMS (on SNMP port 162).
        You should be able to query agent from NMS on new mapped port (e.g. 163, or your configured port in in step 5).
        If PowerChute Agent SNMP Traps are configured, you can test real SNMP Traps test by doing a Lost Comms Test.

         

        What is the part number of the S3 sized mechanism to suit the Strato or Modena range?

        80MML is rocker switch module, size S3 - 1 way / 2 way with Blue LED to suit the Strato or Modena range.
        Key Features:
        • Rocker switches with 16A rating for resistive and 16AX rating for inductive/capacitive loads.
        • Terminal size maximised for ease of use.
        • Fully shrouded and clearly marked terminals for faster installation.


         

        What is the part number of the S2, standard sized mechanism to suit the Strato or Modena range?

        80ML is rocker switch module, size S2 - 1 way / 2 way with Blue LED to suit the Strato or Modena range.
        Key Features:
        • Rocker switches with 16A rating for resistive and 16AX rating for inductive/capacitive loads.
        • Terminal size maximised for ease of use.
        • Fully shrouded and clearly marked terminals for faster installation.

        Below is the configuration in S6 sized Grid plate

        For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=80ML

        What is the part number of S6, large sized mechanism to suit Modena and Strato range?

        80MLL is a rocker switch module, size S6 - 1 way / 2 way with Blue LED to suit the Strato or Modena range.
        Key Features:
        • Rocker switches with 16A rating for resistive and 16AX rating for inductive/capacitive loads.
        • Terminal size maximised for ease of use.
        • Fully shrouded and clearly marked terminals for faster installation.

        Below is configuration on a S6 grid:


        For further information, please visit https://www.clipsal.com/Trade/Products/ProductDetail?catno=80MLL

        What is the part code for a 2P 16A 6kA C-curve circuit breaker

         The part code is 25817

        What is the code for a 10kA 16A 1p C Curve MCB?

         The code is A9F54116

        What is the part code for the PDL Modena standrd (S2) 16A module

        PDL881M16S

        What is the part number for a 5pin 16A 56 series socket?



        PDL56SO516CEELEGY

        Do you have a Saturn Series single gang switch rated at 20A?

        Yes, the standard switches are rated at 20A and 16AX (fluorescent load).

        How to increase the number of available serial connections in ION Setup above 16?

        Issue
        When attempting to connect to a serial device in ION Setup a user receives the message: ‘Serial port not available’.
        Product Line
        ION Setup
        Environment
        ION Setup Serial Connections
        Cause
        By default ION Setup supports 16 serial connections and 240 TCP connections. (TCP connections are defined as sites where one can have, say 10 Ethernet devices, connected to a single Ethernet site which will not be counted as 10 TCP connections).
        Resolution
        This default division between serial and TCP connections can be controlled by modifying a setting located in the IONSETUP.INI file. Please change the ‘SerialPorts’ to the desired number from 16. Save the change before exiting the file.

        You can locate the directory that contains the IONSETUP.ini file by opening ION Setup and selecting "Tools -> Options -> Directories"   
        The "Config Directory" file path is where the IONSETUP.ini file is located.
         
        Example:
        [Communications]
        SerialPorts=16
        UpgradeThrottling=1

        Change the value from 16 to 17 to gain an additional serial port.
        [Communications]
        SerialPorts=17
        UpgradeThrottling=1
         
        Please note, the serial port number increment will take place in expense of TCP ports. So, if we increase the serial connections to 17, there will be 239 TCP connections available.

        What is the part number for a 50kA NSX400 C/B with micrologic 2.3 unit with trip range - 160 - 400amps?

        The part number for a 50kA NSX400 C/B with micrologic 2.3 unit with trip range - 160 - 400amps is - LV432693

        For further information , visit link below:-
        https://www.schneider-electric.com.au/en/search/LV432693
        User-added image

        What is the part code for a 16A Relay Module?

         The PDL600RM is rated 16A resistive (6A inductive) and has a NO & NC contact. It is a 600 series module so can be mounted in a grid plate, but doesn't have to be as there is no built in indication as to the state of the contacts.

        Do you do a 16A B curve RCBO?

        No, unfortunately we only do C curves in the combination breakers.

        For further information please visit https://www.clipsal.com/Trade/search-results?q=rcbo

         
        Show More