Relay type
speed control relays
Relay monitored parameters
Time delay range
0.6...60 s adjustable on energisation delay (tolerance: 0...10 % of the full scale value)
Switching capacity in VA
1250 VA
Minimum switching current
10 mA at 5 V DC
[Us] rated supply voltage
24...240 V AC/DC
Maximum power consumption in VA
5 VA AC
Measurement range
- 0.05...0.5 s
- 0.5...5 min
- 1...10 min
- 1...10 s
- 0.5...5 s
- 0.1...1 s
- 0.1...1 min
Utilisation category
- AC-12 conforming to IEC 60947-5-1
- AC-13 conforming to IEC 60947-5-1
- AC-14 conforming to IEC 60947-5-1
- AC-15 conforming to IEC 60947-5-1
- DC-12 conforming to IEC 60947-5-1
- DC-13 conforming to IEC 60947-5-1
- DC-14 conforming to IEC 60947-5-1
[Uc] control circuit voltage
24...240 V
Contacts type and composition
1 C/O
Reset time
- 50 ms contact S2 in memory mode on time delay
- 1 s supply Un in memory mode on time delay
Maximum switching voltage
250 V AC/DC
Supply voltage limits
20.4...264 V AC/DC
Maximum power consumption in W
3 W DC
Nominal output current
5 A
Run-up delay at power-up
0.05 s
Hysteresis
5 % of threshold
Measurement accuracy
+/- 10 % of the full scale value
Repeat accuracy
- +/- 0.5 % for input and measurement circuit
- +/- 0.5 % for time delay
Measurement error
- +/- 0.1 %/°C with temperature variation
- < +/-="" 1="" %="" over="" the="" whole="" range="" with="" voltage="">
Input frequency
0.0017...20 Hz
Response time
15 ms max (on crossing the threshold)
Polarity
reversible polarity on DC supply
Threshold setting
10...100 %
[Us] rated supply voltage
11.5...12.5 V
Maximum supply current for sensors
- 40 mA for < 24="" v="" ac="" at="" 25="">
- 40 mA for < 24="" v="" dc="" at="" 25="">
- 50 mA for 24...240 V AC
- 50 mA for 24...240 V DC
Impulse duration
- >= 5 ms high state
- >= 5 ms low state
Input compatibility
- 3-wire sensor (E1) PNP or NPN, 12 V, 50 mA
- NAMUR sensor (E2), 12 V, 1.5 kOhm
- voltage input (E1), 0...30 V, 9.5 kOhm, high state >= 4.5 V low state <= 1="">=>
- volt-free contact input (E1), 12 V, 9.5 kOhm
Overvoltage category
III conforming to IEC 60664-1
[Ui] rated insulation voltage
250 V conforming to IEC 60664-1
Control circuit voltage limits
- 15 % + 10 % Un
Supply frequency
50/60 Hz +/- 10 %
Operating position
any position without derating
Tightening torque
0.6...1 N.m conforming to IEC 60947...1
Housing material
self-extinguishing plastic
Status LED
- 1 LED green for power ON
- 1 LED yellow for inhibit
- 1 LED yellow for relay (R)
Operating rate
<= 360="" operations/hour="" full="">=>
Immunity to microbreaks
50 ms
Electromagnetic compatibility
- emission standard for industrial environments conforming to EN/IEC 61000-6-4
- emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
- immunity for industrial environments conforming to NF EN/IEC 61000-6-2
Vibration resistance
- 0.35 mm (f= 5-57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1
- 1 gn (f= 57.6-150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1
Shock resistance
15 gn for 11 ms conforming to IEC 60255-21-1
Pollution degree
3 conforming to IEC 60664-1
Dielectric test voltage
2 kV AC 50 Hz
Non-dissipating shock wave
4 kV
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Unit Type of Package 2
S03
Number of Units in Package 2
48
Package 2 Weight
7.181 kg
WEEE
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins