Contacts type and composition
1 C/O
[Us] rated supply voltage
12 V AC/DC 50/60 Hz
Voltage range
0.9...1.2 Us
Supply frequency
50...60 Hz +/- 5 %
Tightening torque
0.6...1 N.m conforming to IEC 60947...1
Housing material
self-extinguishing
Repeat accuracy
+/- 0.5 % conforming to IEC 61812-1
Temperature drift
+/- 0.05 %/°C
Voltage drift
+/- 0.2 %/V
Setting accuracy of time delay
+/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Impulse duration
- 100 ms with load in parallel typical
- 30 ms typical
Reset time
120 ms on de-energisation typical
Power consumption in VA
0.7 VA at 12 V AC
Maximum power consumption in W
0.5 W at 12 V DC
Minimum switching current
10 mA at 5 V DC
Maximum switching current
8 A AC/DC
Maximum switching voltage
250 V AC
Breaking capacity
2000 VA
Operating rate in Hz
10 Hz
Dielectric strength
2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
[Uimp] rated impulse withstand voltage
5 kV during 1.2/50 µs
Maximum delay response
100 ms
Creepage distance
4 kV/3 conforming to IEC 60664-1
Safety reliability data
- MTTFd = 296.8 years
- B10d = 270000
Time delay type
A, Ac, At, B, Bw, C, D, Di, H, Ht
Functionality
multifunction
Immunity to microbreaks
20 ms
Vibration resistance
20 m/s² (f= 10-150 Hz) conforming to IEC 60068-2-6
Shock resistance
15 gn for 11 ms conforming to IEC 60068-2-27
Electromagnetic compatibility
- electrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2
- electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2
- susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC 61000-4-3
- electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to IEC 61000-4-4
- electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4
- 1.2/50 µs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5
- 1.2/50 µs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5
- conducted RF disturbances: (0.15...80 MHz), level 3, 10 V, conforming to IEC 61000-4-6
- voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11
- voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11
- conducted and radiated emissions: , class B, conforming to EN 55022
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Unit Type of Package 2
S02
Number of Units in Package 2
40
Package 2 Weight
3.475 kg
Discrete output type
relay
Time delay type
- power on-delay
- on-delay and off-delay
- interval
- off-delay
- symmetrical flashing
Time delay range
- 1...10 s
- 6...60 s
- 10...100 h
- 1...10 min
- 1...10 h
- 0.1...1 s
- 6...60 min
Nominal output current
8 A
[Uc] control circuit voltage