Quantcast

Square D QOvs Earth Leakage Circuit Breaker, 1P + Ns, B Curve, 20A, 30mA

Square D QOvs Earth Leakage Circuit Breaker, 1P + Ns, B Curve, 20A, 30mA

Square D QOvs Earth Leakage Circuit Breaker, 1P + Ns, B Curve, 20A, 30mA

Item Number: QO120B10RCBO30F

Retail
$1,203.48
RRP (Inc. GST)

Product Dimensions

Width icon

Width19 mm

Height icon

Height110 mm

Depth icon

Depth85 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

Square D

Range of product

Square D

Product or component type

residual current breaker with overcurrent protection (RCBO)

Sustainable offer status

Green Premium product

Physical

[In] rated current

20 A at 40 °C

[Ue] rated operational voltage

230/240 V AC 50/60 Hz

Electrical insulation class

class II

Control type

toggle

Local signalling

ON/OFF indication

Mounting mode

plug-on

Mounting support

socket

Height

110 mm

Width

19 mm

Depth

85 mm

Net weight

186 g

Mechanical durability

20000 cycles

Electrical durability

5000 cycles

Connections - terminals

  • plug-in connector (top)
  • tunnel type terminal (bottom) 1-16 mm² rigid without cable end
  • tunnel type terminal (bottom) 1-10 mm² with cable end
  • tunnel type terminal (bottom) 1-10 mm² flexible without cable end
    • Wire stripping length

      power circuit: 15 mm for bottom connection

      Standards

    • IEC 61009-2-2
    • AS/NZS 61009.1
    • BS EN 61009-1
    • IEC 61009-1
      • IP degree of protection

        IP20

        Relative humidity

        95-95 % at 55-55 °C

        Ambient air temperature for operation

        -15-60 °C

        Ambient air temperature for storage

        -40-85 °C

        REACh Regulation

        Free of Substances of Very High Concern above the threshold

        EU RoHS Directive

        Compliant

        Mercury free

        Yes

        RoHS exemption information

        Yes

        China RoHS Regulation

        Product out of China RoHS scope. Substance declaration for your information

        Environmental Disclosure

        ENVPEP1306051EN

        Circularity Profile

        ENVEOLI1306051_V1

        Others

        Circuit breaker application

        distribution

        Product name

        QOvs RCBO

        Poles description

        1P + Ns

        Earthing system

        TN

        Curve code

        B

        Earth-leakage sensitivity

        30 mA

        Breaking capacity

        10000 A Icn at 230/240 V AC 50/60 Hz

        Number of protected poles

        1

        Device location in system

        outgoer

        Network frequency

        50/60 Hz

        Network type

        AC

        Trip unit technology

        thermal-magnetic

        Residual current tripping technology

        voltage dependent functional earth

        Earth-leakage protection time delay

        instantaneous

        Earth-leakage protection class

        type AC

        [Icw] rated short-time withstand current

        Icw: 250 A during 8/20 µs impulse withstand

        [Ics] rated service breaking capacity

        7500 A at 230/240 V AC 50/60 Hz

        Limitation class

        3

        [Ui] rated insulation voltage

        400 V AC 50/60 Hz

        [Uimp] rated impulse withstand voltage

        4 kV

        Surge current

        250 A

        Suitability for isolation

        yes

        Contact position indicator

        yes

        Comb busbar and distribution block compatibility

        NO

        Provision for padlocking

        non padlockable

        Tightening torque

        power circuit: 2-2 N.m bottom

        Earth-leakage protection

        integrated

        Tropicalisation

        2

        Unit Type of Package 1

        PCE

        Number of Units in Package 1

        1

        Package 1 Weight

        232 g

        Package 1 Height

        10.3 cm

        Package 1 width

        14.3 cm

        Package 1 Length

        2.7 cm

        WEEE

        The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
        Show all specifications

        Frequently Asked Questions

        hide show

        What are the ranges of the Square D Circuit Breakers?

        MaterialDescriptionCommentDirect Replacement
        QO106EC10MINIATURE CIRCUIT BREAKER 240V 6ADiscontinuedno replacement
        QO110EC10QOvs 1P 10A 10kA Type CDirect ReplacementQO110VSC10
        QO116EC10QOvs 1P 16A 10kA Type CDirect ReplacementQO116VSC10
        QO120EC10QOvs 1P 20A 10kA Type CDirect ReplacementQO120VSC10
        QO125EC10QOvs 1P 25A 10kA Type CDirect ReplacementQO125VSC10
        QO132EC10QOvs 1P 32A 10kA Type CDirect ReplacementQO132VSC10
        QO140EC10QOvs 1P 40A 10kA Type CDirect ReplacementQO140VSC10
        QO150EC10QOvs 1P 50A 10kA Type CDirect ReplacementQO150VSC10
        QO163EC10QOvs 1P 63A 10kA Type CDirect ReplacementQO163VSC10
        QOH180XAUSMCB QOH 1P 80A 6KADiscontinuedno replacement
        QOH1100XAUSMCB QOH 1P 100A 6KADiscontinuedno replacement
        QO310EC10QOvs 3P 10A 10kA Type CDirect ReplacementQO310VSC10
        QO316EC10QOvs 3P 16A 10kA Type CDirect ReplacementQO316VSC10
        QO320EC10QOvs 3P 20A 10kA Type CDirect ReplacementQO320VSC10
        QO325EC10QOvs 3P 25A 10kA Type CDirect ReplacementQO325VSC10
        QO332EC10QOvs 3P 32A 10kA Type CDirect ReplacementQO332VSC10
        QO340EC10QOvs 3P 40A 10kA Type CDirect ReplacementQO340VSC10
        QO350EC10QOvs 3P 50A 10kA Type CDirect ReplacementQO350VSC10
        QO363EC10QOvs 3P 63A 10kA Type CDirect ReplacementQO363VSC10
        QOH380XAUSMCB QOH 3P 80A 6KADiscontinuedno replacement
            
        RCBO   
        QOE110BO3QOE RCBO 1P+N 10A B 30mA 10kADirect ReplacementQO110B10RCBO30F
        QOE116BO3QOE RCBO 1P+N 16A B 30mA 10kADirect ReplacementQO116B10RCBO30F
        QOE120BO3QOE RCBO 1P+N 20A B 30mA 10kADirect ReplacementQO120B10RCBO30F
        QOE132BO3QOE RCBO 1P+N 32A B 30mA 10kADirect ReplacementQO132B10RCBO30F
        QOE140BO3QOE RCBO 1P+N 40A B 30mA 10kADirect ReplacementQO140B10RCBO30F

        Can Square D (QO120B10RCBO30F) breakers be replaced with Acti 9 breakers?

        No, only Square D breakers will fit to the Square D chassis and vice versa, this is due to the special mount requirements.

        What is the part number for a 20amp Square D RCBO?

        What are the replacement part numbers for a Square D RCBOs example QOE120B03?

        Please see attached document for the charcateristics of the new RCBos and below table shows the replacemnet part#s
        RCBO   
        MaterialAlternative MaterialDescriptionComment
        QOE110BO3QO110B10RCBO30FQOE RCBO 1P+N 10A B 30mA 10kADirect Replacement
        QOE116BO3QO116B10RCBO30FQOE RCBO 1P+N 16A B 30mA 10kADirect Replacement
        QOE120BO3QO120B10RCBO30FQOE RCBO 1P+N 20A B 30mA 10kADirect Replacement
        QOE132BO3QO132B10RCBO30FQOE RCBO 1P+N 32A B 30mA 10kADirect Replacement
        QOE140BO3QO140B10RCBO30FQOE RCBO 1P+N 40A B 30mA 10kADirect Replacement