Medilec Amber Power Available Neon with F30Z1.5 Mounting Clip

Medilec Amber Power Available Neon with F30Z1.5 Mounting Clip

Medilec Amber Power Available Neon with F30Z1.5 Mounting Clip

Item Number: N01

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Product brand

Clipsal

Range of product

ESP Metal Plate Series

Physical

[Ue] rated operational voltage

240 V AC

EU RoHS Directive

Compliant

Mercury free

Yes

RoHS exemption information

Yes

China RoHS Regulation

Product out of China RoHS scope. Substance declaration for your information

Others

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Weight

11.0 g

Package 1 Height

3 cm

Package 1 width

3 cm

Package 1 Length

3 cm
Show all specifications

Frequently Asked Questions

hide show

Is there a thru the door external operator for the GV2ME and GV2P manual starters?

Issue:
What is the through-the-door operating mechanism for a GV2 Manual starter?

Product Line: 
Digest 177 Section 18 : Contactors and Starters - IEC

Environment:
North American Products

Cause:
Needs  the through-the-door operating mechanism for a GV2P Manual starter

Resolution:
There are no available kits for the GV2ME devices, only the GV2P devices (as listed below)
GV2APN01 - Nema 1 Black
GV2APN02 - Nema 1, 12 Red/Yellow
GV2APN04 - Nema 3R, 4, 4X Red/Yellow
 

Can the single pole LA1DN and LADN auxiliary contact module be mounted on the TeSys contactors?

ISSUE
In which contactors can the LA1DN and LADN auxiliary contacts be mounted?

PRODUCT LINE
Auxiliary contacts for the Tesys D line

ENVIRONMENT
Tesys D-Line and Tesys F

RESOLUTION
These contacts will only fit on the following contactors:
Front mount only for LC1D40 through LC1D115 devices and LC1D40A - LC1D65A.
Left side mount only to LC1F contactors

Will a single circuit auxiliary contact block, like a LADN10 or LADN01, fit onto the Tesys D09-D38 amp contactors?

Issue:
Identifying auxiliary contact blocks for Tesys D contactors

Product Line:
IEC contactors and starters

Environment:
Tesys D Auxiliary contact blocks

Cause:
single auxiliary contact block needed for use on a Tesys D line contactor

Resolution:
No, the single pole contact block will not fit . A LADN11,LADN20, LADN02 etc will fit. Anything with 2 auxiliary contacts in one block will fit.

Is there a through the door operating mechanism for the GV3P manual starters?

Issue:
GV3P Through the door mechanisms options

Product Line:
IEC Contactors and Starters

Environment:
GV3P Manual Starters and Protectors

Cause:
Product selection/feature
 
Resolution:
There are three different through the door operating mechanisms for the GV3P. There is the GV3APN01 which is rated
NEMA 1 and 12 in black with trip indication; the GV3APN02 which is also NEMA 1 and 12 in red/yellow with trip indication,
and the GV3APN04 which is NEMA 4/X red/yellow without trip indication.
 

GV2P disconnect options

Issue:
What is the product number for a complete through-the-door disconnect device for a GV2P

Product Line:
IEC Contactors and Starters

Environment:
GV2P Manual Starters and Protectors

Resolution:
There are three devices which include mechanism, shaft and handle:
GV2APN01 has a NEMA 1, 12 rating and is black
GV2APN02 has a NEMA 1, 12 rating and is red/yellow
GV2APN04 has a NEMA 3R, 4, 4X rating and is red/yellow

What's the difference between a regular Home member, an Administrator and the Homeowner?

The Homeowner has access to all functions. Administrator has access to all functions except the ability to transfer the homeowner rights, delete the home and granting administrator rights to other members. A common member only has access to operate devices, receive notifications (alarm, moment/automation trigger, device added/removed and invite) from a home, configure device settings and schedules.