Spare Coils

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range of product

TeSys D

Range

TeSys

Product or component type

contactor coil

Product compatibility

  • LC1D95
  • LC1D80
    • Warranty

      18 months

      Physical

      Mechanical durability

      4 Mcycles

      Ambient air temperature for operation

      -5-60 °C

      Net weight

      0.28 kg

      Others

      Device short name

      LX1D6

      Control circuit type

      AC at 50/60 Hz

      [Uc] control circuit voltage

      24 V AC 50/60 Hz

      Average resistance

      1.22 Ohm at 20 °C

      Inductance of closed circuit

      0.08 H

      Maximum operating rate

      3600 cyc/h 60 °C

      Coil technology

      without built-in suppressor module

      Control circuit voltage limits

    • drop-out: 0.3...0.6 Uc at 50/60 Hz (at <55 °C)
    • operational: 0.8...1.1 Uc at 50 Hz (at <55 °C)
    • operational: 0.85...1.1 Uc at 60 Hz (at <55 °C)
      • Inrush power in VA

      • 245-245 VA 60 Hz cos phi 0.75 (at 20 °C)
      • 245-245 VA 50 Hz cos phi 0.75 (at 20 °C)
        • Hold-in power consumption in VA

        • 26-26 VA 60 Hz cos phi 0.3 (at 20 °C)
        • 26-26 VA 50 Hz cos phi 0.3 (at 20 °C)
          • Heat dissipation

            6-10 W at 50/60 Hz

            Unit Type of Package 1

            PCE

            Number of Units in Package 1

            1

            Package 1 Weight

            310 g

            Package 1 Height

            5.5 cm

            Package 1 width

            12.5 cm

            Package 1 Length

            8.5 cm

            Unit Type of Package 2

            S02

            Number of Units in Package 2

            16

            Package 2 Weight

            5.395 kg

            Package 2 Height

            15 cm

            Package 2 width

            30 cm

            Package 2 Length

            40 cm
            Show all specifications

            Documents & downloads

            hide show
            Filter items
            • All

            • Product Brochures

            • Technical Data Catalogues

            • Installation Instruction

            • Product Environmental

            Frequently Asked Questions

            hide show

            What is the replacement AC coil for LC1D/LC2D40, D50, D65, D80, and D95?

            Issue:
            AC Coil information for LC1D/LC2D40, D50, D65, D80, and D95

            Product Line:
            Tesys D Replacement Parts

            Environment:
            TeSys™ D AC Coils

            Resolution:

            What is the 240V coil needed for a LC1D80008 contactor

             The coil is a LX1D6U7

            spare 415VAC coil for LC1D80 Contactor ?

            Code = LX1D6N7

            What is the replacement for LC1D115 with LX1D6G7 coil?

            The replacement for LC1D115 with LX1D6G7 coil is LC1D1156F7

            LC1D1156F7
            TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 115 A - 110 V AC 50/60 Hz coil

            For more information see:
            https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LC1D1156F7

            What is the altitude derating for a TeSys D-Line contactor?

            Issue:​
            What is the altitude derating for a TeSys D-Line contactor?

            Product Line:
            Digest 177 Section 18 : Contactors and Starters, IEC

            Environment:
            North American Products

            Resolution:
            The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

            Voltage
            3500m x 0.90
            4000m x 0.80
            4500m x 0.70
            5000m x 0.60

            Current
            3500m x 0.92
            4000m x 0.90
            4500m x 0.88
            5000m x 0.86

            For example, an LC1D80 at 5000 meters:
            - The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
            - The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



             

            What is the power terminal lug data for the LC1D40, LC1D50, LC1D65, LP1D40, LP1D50, and LP1D65 contactor?

            Issue:
            Identifying power terminal lug data for the D2 style contactors

            Product Line:
            IEC Contactors and Starters

            Environment:
            Tesys D line contactors

            Cause:
            Power terminal lug data required

            Resolution:
            For contactors with screw clamp terminals:
            stranded cable w/o cable end : One #10-3 AWG or Two #10-4 AWG per terminal.
            stranded cable w/cable end: One #10-4 AWG or Two #12-2 AWG per terminal.
            solid cable: One #10-3 AWG or Two #10-6 AWG per terminal.
            Show More