TeSys LRD Thermal Overload Relays, 4...6A Class, 10A

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Product or component type

differential thermal overload relay

Product compatibility

  • LC1D09
  • LC1D32
  • LC1D38
  • LC1D12
  • LC1D18
  • LC1D25
    • Sustainable offer status

      Green Premium product

      Warranty

      18 months

      Physical

      Mounting support

    • plate, with specific accessories
    • rail, with specific accessories
    • under contactor
      • [Ue] rated operational voltage

        690 V AC 0...400 Hz

        Control type

      • red push-button: stop
      • blue push-button: reset
        • Connections - terminals

        • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm² flexible without cable end
        • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm² flexible with cable end
        • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm² solid without cable end
        • power circuit: screw clamp terminals 1 cable(s) 1.5-10 mm² flexible without cable end
        • power circuit: screw clamp terminals 1 cable(s) 1-4 mm² flexible with cable end
        • power circuit: screw clamp terminals 1 cable(s) 1-6 mm² solid without cable end
          • Width

            45 mm

            Depth

            70 mm

            Net weight

            0.124 kg

            IP degree of protection

            IP20 conforming to IEC 60529

            Ambient air temperature for operation

            -20-60 °C without derating conforming to IEC 60947-4-1

            Ambient air temperature for storage

            -60-70 °C

            Standards

          • ATEX D 94/9/CE
          • UL 508
          • IEC 60947-4-1
          • EN 60947-4-1
          • EN 60947-5-1
          • CSA C22.2 No 14
          • IEC 60947-5-1
            • Product certifications

            • CCC
            • CSA
            • ATEX INERIS
            • LROS (Lloyds register of shipping)
            • UL
            • GL
            • BV
            • DNV
            • GOST
            • RINA
              • REACh free of SVHC

                Yes

                EU RoHS Directive

                Compliant

                Mercury free

                Yes

                RoHS exemption information

                Yes

                China RoHS Regulation

                Product out of China RoHS scope. Substance declaration for your information

                Environmental Disclosure

                ENVPEP080206EN

                Circularity Profile

                ENVEOLI0802006

                Others

                Product name

                TeSys LRD

                Device short name

                LRD

                Relay application

                motor protection

                Network type

              • DC
              • AC
                • Thermal protection adjustment range

                  4-6 A

                  [Ui] rated insulation voltage

                • power circuit: 600 V conforming to CSA
                • power circuit: 600 V conforming to UL
                • power circuit: 690 V conforming to IEC 60947-4-1
                  • Network frequency

                    0...400 Hz

                    Tripping threshold

                    1.14 +/- 0.06 Ir conforming to IEC 60947-4-1

                    [Ith] conventional free air thermal current

                    5 A for signalling circuit

                    Permissible current

                  • 3 A at 120 V AC-15 for signalling circuit
                  • 0.22 A at 125 V DC-13 for signalling circuit
                    • [Uimp] rated impulse withstand voltage

                      Phase failure sensitivity

                      tripping current 130 % of Ir on two phase, the last one at 0

                      Temperature compensation

                      -20-60 °C

                      Tightening torque

                    • control circuit: 1.7 N.m - on screw clamp terminals
                    • power circuit: 1.7 N.m - on screw clamp terminals
                      • Compatibility code

                        LRD

                        Protective treatment

                        TH conforming to IEC 60068

                        Flame retardance

                        V1 conforming to UL 94

                        Mechanical robustness

                      • vibrations: 6 Gn conforming to IEC 60068-2-6
                      • shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7
                        • Dielectric strength

                          6 kV at 50 Hz conforming to IEC 60255-5

                          Unit Type of Package 1

                          PCE

                          Number of Units in Package 1

                          1

                          Package 1 Weight

                          142 g

                          Package 1 Height

                          8.8 cm

                          Package 1 width

                          7.8 cm

                          Package 1 Length

                          5 cm

                          Unit Type of Package 2

                          S02

                          Number of Units in Package 2

                          24

                          Package 2 Weight

                          3.723 kg

                          Package 2 Height

                          15 cm

                          Package 2 width

                          30 cm

                          Package 2 Length

                          40 cm

                          Unit Type of Package 3

                          P06

                          Number of Units in Package 3

                          384

                          Package 3 Weight

                          68.068 kg

                          Package 3 Height

                          77 cm

                          Package 3 width

                          80 cm

                          Package 3 Length

                          60 cm

                          WEEE

                          The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                          Show all specifications

                          Documents & downloads

                          hide show
                          Filter items
                          • All

                          • CAD Files and Packs

                          • Product Brochures

                          • Technical Data Catalogues

                          • Handout

                          • Product Environmental

                          • End of Life Manual

                          • Installation Instruction

                          • Certificates (MSDS)

                          • Declaration of Conformity

                          Frequently Asked Questions

                          hide show

                          What are the wiring terminals on the IEC LRD* overload relays?

                          Product Line:
                          Tesys D line Overload Relays
                           
                          Resolution:
                          The normally closed overload contact are terminals 95 & 96; and the normally open overload contact are terminals 97 & 98.
                          T1 T2 and T3 are the load terminals. 

                          The normally closed control circuit contact will open when there is a fault, this contact is typically used in series with the control circuit. 

                          The normally open trip signal contact closes when a fault occurs which is typically used to control a pilot light, or alarm. 

                           

                          Is there a replacemnet for the old DOL motor starters like LE1D12U7R10?

                          All of the LE1D12U7R** parts have now been Divide into two parts enclosed starter and thermal overload see table for the new part numbers/ format:
                           
                          Old Part Numbers Enclosed Starter Thermal Overload
                          LE1D12U7R10 LE1D12U7S48 plus LRD10
                          LE1D12U7R12 LE1D12U7S48 plus LRD12
                          LE1D12U7R14 LE1D12U7S48 plus LRD14
                          LE1D12U7R16 LE1D12U7S48 plus LRD16

                          For further information please visit https://www.clipsal.com/Trade

                           

                          What is the overload to suit LE3D12N7 star delta starter?

                          Overload to suit LE3D12N7 will be either LRD12, LRD14 or LRD16 depending on application.

                          Alternative Overload for the PDL56T992 (6.0-9.2A)

                          Either go for the LRD12 (5.0-8.0A) or the LRD14 (7.0-10.0A) depending on the size of the motor. This will not fit the old 56 Series DOL starter

                          What is the part code for a Thermal Overload 9-13A

                          The part code is LRD16 overload

                          What is the Din rail terminal block to suit the LRD12?

                          The LAD7B106 fits the LRD01 to LRD35 range.
                           

                          What is the part code for a DOL 1P 240V AC Coil 4kW 9A, with 10-12A overload

                          Use a PDL56DOL9LOBGY and a LRD16 overload.

                          What is the 415v remote reset for the LRD14 overload?

                          The part number for the415VAC or DC remote reset for the LRD01...35 and the LRD313....365 is LAD703N
                          See data sheet for more information......https://eshop.schneider-electric.com/product.aspx?org=21&lang=1&dist=276&prod_id=LAD703N...User-added image
                           

                          What is the replacement for a Clipsal 6CTR38/15?

                          This is part of the old Clipsal 6 series contactors which are no longer available .It is an old Clipsal overload, which would need to be changed over to a Schneider LC1D range contactor with overload to suit . Over load to use is either LRD21 for 12-18A or LRD16 for 9-13A

                          For correct selection of contactor and overload required please call Schneider Electric on 1300 369 233

                          What is the difference between the LA7D305 and LAD7305, remote control reset mechanism by flexible cable?

                          Issue:
                          Identifying differences between two similar part numbers.

                          Product Line:
                          IEC contactors and starters

                          Environment:
                          Products sold and used in the United States

                          Cause:
                          Choosing the correct part number

                          Resolution:
                          LAD7305 is for use on LRD01 to LRD35 , LR3D01 to LR3D35, and LRD313 to LRD365.
                          LA7D305 is for use on all other relays (except LRD01 to LRD35 and LR3D01 to LR3D35).

                           

                          What is the alternative for PDL56T9120 overload?

                          The alternative is LRD16 but this will not fit the contactor in the 56 series starter as it is for the LC1D range of contactors. The PDL56T9120 is no longer available.
                          The new range of 56 series starters, 56DOL, have LC1D contactors and LRD overloads (not fitted).

                          What is the difference between a LR3D21 and LRD21?

                          Show More