MASTER YOUR CASTLE with your new build or reno project
Enter competition
BIMETALLIC O/LOAD RELAY 575VAC 0.16A IEC
Thermal overload relay for motor TeSys - 0.1A…2.5 A - class 10A
BIMETALLIC O/LOAD RELAY 575VAC 0.16A IEC
Thermal overload relay for motor TeSys - 0.1A…2.5 A - class 10A

LRD01

TeSys LRD Thermal Overload Relays, 0.1...0.16A Class, 10A

BIMETALLIC O/LOAD RELAY 575VAC 0.16A IEC
Thermal overload relay for motor TeSys - 0.1A…2.5 A - class 10A
BIMETALLIC O/LOAD RELAY 575VAC 0.16A IEC
Thermal overload relay for motor TeSys - 0.1A…2.5 A - class 10A
Colour:
Colour: Per UOM Std.
  • 1 PCE
Added to cart
Successfully added, you can view your cart here

Key Features & Specifications

hide show
Range
TeSys
Product name
TeSys LRD
Product or component type
differential thermal overload relay
Device short name
LRD
Relay application
motor protection
Product compatibility
  • LC1D25
  • LC1D09
  • LC1D12
  • LC1D18
  • LC1D38
  • LC1D32
    • Network type
    • DC
    • AC
      • Thermal protection adjustment range
        0.1-0.16 A
        [Ui] rated insulation voltage
      • power circuit: 600 V conforming to CSA
      • power circuit: 600 V conforming to UL
      • power circuit: 690 V conforming to IEC 60947-4-1
        • Network frequency
          0...400 Hz
          Mounting support
        • plate, with specific accessories
        • rail, with specific accessories
        • under contactor
          • Tripping threshold
            1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
            [Ith] conventional free air thermal current
            5 A for signalling circuit
            Permissible current
          • 3 A at 120 V AC-15 for signalling circuit
          • 0.22 A at 125 V DC-13 for signalling circuit
            • [Ue] rated operational voltage
              690 V AC 0...400 Hz
              [Uimp] rated impulse withstand voltage
              6 kV
              Phase failure sensitivity
              tripping current 130 % of Ir on two phase, the last one at 0
              Control type
            • red push-button: stop
            • blue push-button: reset
              • Temperature compensation
                -20-60 °C
                Connections - terminals
              • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm² flexible without cable end
              • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm² flexible with cable end
              • control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm² solid without cable end
              • power circuit: screw clamp terminals 1 cable(s) 1.5-10 mm² flexible without cable end
              • power circuit: screw clamp terminals 1 cable(s) 1-4 mm² flexible with cable end
              • power circuit: screw clamp terminals 1 cable(s) 1-6 mm² solid without cable end
                • Tightening torque
                • control circuit: 1.7 N.m - on screw clamp terminals
                • power circuit: 1.7 N.m - on screw clamp terminals
                  • Width
                    45 mm
                    Depth
                    70 mm
                    Net weight
                    0.124 kg
                    Compatibility code
                    LRD
                    Protective treatment
                    TH conforming to IEC 60068
                    IP degree of protection
                    IP20 conforming to IEC 60529
                    Ambient air temperature for operation
                    -20-60 °C without derating conforming to IEC 60947-4-1
                    Ambient air temperature for storage
                    -60-70 °C
                    Flame retardance
                    V1 conforming to UL 94
                    Mechanical robustness
                  • vibrations: 6 Gn conforming to IEC 60068-2-6
                  • shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7
                    • Dielectric strength
                      6 kV at 50 Hz conforming to IEC 60255-5
                      Standards
                    • EN 60947-4-1
                    • EN 60947-5-1
                    • IEC 60947-5-1
                    • IEC 60947-4-1
                    • UL 508
                    • ATEX D 94/9/CE
                    • CSA C22.2 No 14
                      • Product certifications
                      • RINA
                      • BV
                      • CCC
                      • GL
                      • UL
                      • GOST
                      • CSA
                      • DNV
                      • LROS (Lloyds register of shipping)
                      • ATEX INERIS
                        • Sustainable offer status
                          Green Premium product
                          REACh Regulation
                          Reference contains Substances of Very High Concern above the threshold
                          EU RoHS Directive
                          Pro-active compliance (Product out of EU RoHS legal scope)
                          Mercury free
                          Yes
                          RoHS exemption information
                          Yes
                          China RoHS Regulation
                          Product out of China RoHS scope. Substance declaration for your information
                          Environmental Disclosure
                          ENVPEP080206EN
                          Circularity Profile
                          ENVEOLI0802006
                          WEEE
                          The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                          CALIFORNIA PROPOSITION 65
                          WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.p65warnings.ca.gov
                          Warranty
                          18 months

                          Documents & downloads

                          hide show
                          Filter items
                          • All

                          • CAD Files and Packs

                          • Product Brochures

                          • Technical Data Catalogues

                          • Technical Leaflet

                          • Product Environmental

                          • Installation Instruction

                          • End of Life Manual

                          • Data Bulletin

                          • Operating Manuals

                          • Certificates (MSDS)

                          • White Paper

                          • Marine Certificate

                          • Declaration of Conformity

                          Frequently Asked Questions

                          hide show

                          What is the Din rail terminal block to suit the LRD12?

                          The LAD7B106 fits the LRD01 to LRD35 range.
                           

                          What is the difference between the LA7D305 and LAD7305, remote control reset mechanism by flexible cable?

                          Issue:
                          Identifying differences between two similar part numbers.

                          Product Line:
                          IEC contactors and starters

                          Environment:
                          Products sold and used in the United States

                          Cause:
                          Choosing the correct part number

                          Resolution:
                          LAD7305 is for use on LRD01 to LRD35 , LR3D01 to LR3D35, and LRD313 to LRD365.
                          LA7D305 is for use on all other relays (except LRD01 to LRD35 and LR3D01 to LR3D35).

                           

                          Can the LRD01 to LRD35 range be put back to manual from automatic.

                          This LRD range cannot be put back to Manual reset, once the overlaod has been changed from Manual (factory default) to Automatic.

                          What is the difference between LAD703 and LA7D03

                          Issue:
                          Identifying differences between two similar part numbers

                          Product Line:
                          IEC contactors and starters

                          Environment:
                          Products sold and used in the United States

                          Cause:
                          Identifying differences between two similar part numbers

                          Resolution:
                          Both will remotely stop (trip) or electrically reset the overload, however;
                          LAD703 is used on Tesys overload LRD01 through LRD35 and LR3D01 to LR3D35.
                          LA7D03 is used on all other LR*D overload relays other than LRD01 to LRD35 and LR3D01 to LR3D35.