Quantcast

TeSys, Electronic Thermal Overload Relay, 3P, 22A€¦110A

TeSys, Electronic Thermal Overload Relay, 3P, 22A€¦110A

TeSys, Electronic Thermal Overload Relay, 3P, 22A€¦110A

Item Number: LR9D110S

Retail
$811.65
RRP (Inc. GST)

Product Dimensions

Width icon

Width65 mm

Height icon

Height107 mm

Depth icon

Depth79.9 mm

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Product or component type

electronic thermal overload relay

Product compatibility

  • LC1D50A
  • LC1D38
  • LC1D25
  • LC1D40A
  • LC1D80
  • LC1D65A
  • LC1D115
  • LC1D95
  • LC1D32
    • Sustainable offer status

      Green Premium product

      Physical

      Mounting support

    • plate
    • rail
      • [Ue] rated operational voltage

      • 690 V for power circuit
      • 660 V for signalling circuit
        • Control type

        • red push-button: stop and manual reset
        • white 2 microswitches: adjustable trip class
        • red knob: automatic reset
        • white dial: full-load current adjustment
          • Connections - terminals

          • control circuit: screw clamp terminals 1 cable 2.5-2.5 mm² - cable stiffness: solid or flexible - without cable end
          • power circuit: screw clamp terminals 1 cable 50-50 mm² - cable stiffness: solid or flexible - without cable end
            • Height

              107 mm

              Width

              65 mm

              Depth

              79.9 mm

              Net weight

              0.6 kg

              Standards

            • EN/IEC 60947-4-1
            • EN/IEC 60947-5-1
            • UL 60947-4-1
            • UL 60947-5-1
            • CSA C22.2 No 60947-4-1
            • CSA C22.2 No 60947-5-1
            • GB/T 14048.4
            • GB/T 14048.5
              • Product certifications

              • IECEE CB Scheme
              • UL
              • CSA
              • CCC
                • IP degree of protection

                  IP20 front face conforming to IEC 60529

                  Ambient air temperature for operation

                  -25-70 °C conforming to IEC 60255-8

                  Ambient air temperature for storage

                  -55-80 °C

                  REACh Regulation

                  Free of Substances of Very High Concern above the threshold

                  REACh free of SVHC

                  Yes

                  EU RoHS Directive

                  Compliant

                  Mercury free

                  Yes

                  RoHS exemption information

                  Yes

                  China RoHS Regulation

                  Product out of China RoHS scope. Substance declaration for your information

                  Environmental Disclosure

                  ENVPEP1502001EN

                  Circularity Profile

                  ENVEOLI1502001EN

                  California proposition 65

                  WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

                  Others

                  Product name

                  TeSys LRD

                  Device short name

                  LR9D

                  Relay application

                  motor protection

                  Thermal overload class

                  class 5…30

                  Thermal protection adjustment range

                  22-110 A

                  Maximum power consumption in W

                  300 mW

                  [Ui] rated insulation voltage

                • power circuit: 1000 V
                • signalling circuit: 690 V
                  • Tripping threshold

                    1.25 In conforming to IEC 60947-4-1

                    Time range

                    1.5...4 min - automatic reset time

                    [Ith] conventional free air thermal current

                    5 A for signalling circuit

                    Associated fuse rating

                  • 5 A gG for signalling circuit
                  • 5 A BS for signalling circuit
                    • [Uimp] rated impulse withstand voltage

                      Phase failure sensitivity

                      phase difference > 40% 3-3 s conforming to IEC 60947-4-1

                      Electromagnetic compatibility

                    • surge withstand: 2 kV common mode conforming to IEC 61000-4-5
                    • resistance to electrostatic discharge: 8 kV conforming to IEC 61000-4-2
                    • immunity to radiated radio-electrical interference: 10 V/m conforming to IEC 61000-4-3
                    • immunity to fast transients: 2 kV conforming to IEC 61000-4-4
                      • Tightening torque

                      • control circuit: 0.8 N.m on screw clamp terminals
                      • power circuit: 9 N.m on screw clamp terminals
                        • Operating altitude

                          2000 m without derating

                          Mechanical robustness

                        • vibrations 10...150 Hz: 6 Gn conforming to IEC 60068-2-6
                        • shocks 11 ms: 15 gn conforming to IEC 60068-2-7
                          • Dielectric strength

                            6 kV 50 Hz conforming to IEC 60255-5

                            Unit Type of Package 1

                            PCE

                            Number of Units in Package 1

                            1

                            Package 1 Weight

                            690.9 g

                            Package 1 Height

                            6.7 cm

                            Package 1 width

                            12.1 cm

                            Package 1 Length

                            12.3 cm

                            WEEE

                            The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
                            Show all specifications

                            Documents & downloads

                            hide show
                            Filter items
                            • All

                            • Product Brochures

                            • Technical Data Catalogues

                            • End of Life Manual

                            • Product Environmental

                            • Installation Instruction

                            • Data Bulletin

                            • Declaration of Conformity