Enclosed Starter

Product Dimensions

Width icon

Width186 mm

Height icon

Height348 mm

Depth icon

Depth175.5 mm

See full specifications

Datasheet

Barcode

Qty UoM EAN Colour
-
-
-

Specifications

Design

Range

TeSys

Product or component type

enclosed star-delta starter

Device application

standard

Warranty

18 months

Physical

Control type

  • push-button start green I
  • push-button stop/reset red O
    • Width

      186 mm

      Height

      348 mm

      Depth

      175.5 mm

      Net weight

      3.75 kg

      IP degree of protection

      IP65 conforming to IEC 60529

      IK degree of protection

      IK07 conforming to IEC 60529

      Standards

      IEC 60947-4-1

      Ambient air temperature for operation

      -5-40 °C

      Environmental characteristic

      standard environment

      Material

      Material

      polycarbonate

      Device composition

    • thermal overload relay ordered separately
    • star-delta contactors
    • mechanical interlock
      • Others

        Product name

        TeSys LE

        Device short name

        LE3D

        Utilisation category

        AC-3

        Motor power kW

      • 11 kW at 220 V AC 50/60 Hz
      • 22 kW at 415 V AC 50/60 Hz
      • 22 kW at 440 V AC 50/60 Hz
      • 18.5 kW at 380/400 V AC 50/60 Hz
        • [Uc] control circuit voltage

          110 V AC 50/60 Hz

          Cable entry number

        • 2 ISO20 top
        • 2 ISO25 top
        • 2 ISO32 top
        • 2 ISO40 top
        • 2 ISO20 bottom
        • 2 ISO25 bottom
        • 2 ISO32 bottom
        • 2 ISO40 bottom
          • Compatibility code

            LE3D

            Package 1 Weight

            3.75 kg

            Package 1 Height

            2.6 dm

            Package 1 width

            2.9 dm

            Package 1 Length

            4 dm
            Show all specifications

            Frequently Asked Questions

            hide show

            Where are the control coil terminals for TeSys LC1D09 to LC1D38 contactor?

            Issue:
            Determine the control coil terminal marking and location on LC1D09 to LC1D38 contactor

            Product Line: 
            Tesys D Contactors

            Environment:
            IEC contactors

            Resolution:
            The coil terminals are marked A1 and A2, you can see them on the front of the contactor on the white part (control section).  They are next to the auxiliary contact (13/14, 21/22) terminals.
             

            What is the replacement coil part number for the LC*D09 through LC*D32 and LC*DT20 through LC*DT40 TeSys contactors?

            Issue:
            Identifying replacement coils for tesys D non-reversing and reversing conactors

            Product Line:
            IEC Contactors and Starters

            Environment:
            Products sold and used in the United States

            Cause:
            Replacement coil is needed

            Resolution:
            DC replacement coils are not available.
            AC Coils are 50/60 hertz for voltages as listed below:

            Volts - Part Number
            12 ____ LXD1J7
            21 ____ LXD1Z7
            24 ____ LXD1B7
            32 ____ LXD1C7
            36 ____ LXD1CC7
            42 ____ LXD1D7
            48 ____ LXD1E7
            60 ____ LXD1EE7
            100 ___ LXD1K7 ( never brought to North America )
            110 ___ LXD1F7
            115 ___ LXD1FE7
            120 ___ LXD1G7
            127 ___ LXD1FC7
            200 ___ LXD1L7
            208 ___ LXD1LE7
            220 ___ LXD1M7
            230 ___ LXD1P7
            240 ___ LXD1U7
            277 ___ LXD1W7
            380 ___ LXD1Q7
            400 ___ LXD1V7
            415 ___ LXD1N7
            440 ___ LXD1R7
            480 ___ LXD1T7
            575 ___ LXD1SC7
            600 ___ LXD1X7
            690 ___ LXD1Y7


            Note: A contactor with an AC coil can be changed to a different AC voltage coil, IE you can take an LC1D09 with a 120VAC coil and put a 24VAC coil in it instead. An AC device cannot be switched to a DC coil, and a DC device cannot be switches to an AC coil. 

            Is part number LE3D12N7 available with latching on button?

            No part number LE3D12N7 does not have latching push button.

            What is the plastic arm for LE1D18U7 stop button

            Part code LAD91810

            What replaces a LC1D18M7

            Use the LC1D18U7

            What is the altitude derating for a TeSys D-Line contactor?

            Issue:​
            What is the altitude derating for a TeSys D-Line contactor?

            Product Line:
            Digest 177 Section 18 : Contactors and Starters, IEC

            Environment:
            North American Products

            Resolution:
            The contactors are fully rated up to 3000 meters. Following are derating multipliers for altitudes above 3000 meters for both voltage and current:

            Voltage
            3500m x 0.90
            4000m x 0.80
            4500m x 0.70
            5000m x 0.60

            Current
            3500m x 0.92
            4000m x 0.90
            4500m x 0.88
            5000m x 0.86

            For example, an LC1D80 at 5000 meters:
            - The maximum rated operational voltage is 1,000V (IEC947-4) and 690V (UL/CSA). At 5000 meters it becomes 1000V x 0.6 = 600V (IEC947-4) and 690V x 0.6 = 414V (UL/CSA).
            - The maximum rated operational AC3 current is 80A. At 5000 meters it becomes 80A x 0.86 = 68A.



             

            What is the maximum UL/CSA AC voltage rating of the LC1D power contacts ?

            Issue:
            Identifying maximum voltage of an LC1D contactor

            Product Line:
            TeSys D Contactors

            Environment:
            IEC contactors and starters used in North America

            Cause:
            n/a

            Resolution:
            IThe maximum voltage per UL and CSA is 600VAC. 
             

            What is the overload to suit LE3D12N7 star delta starter?

            Overload to suit LE3D12N7 will be either LRD12, LRD14 or LRD16 depending on application.

            Can the LE1D and LE2D enclosed Tesys D-Line contactors be obtained with DC control coils?

            Issue:  
            Tesys D enclosed starter with a DC control 

            Product Line:
             Enclosed Tesys D line starters

            Environment:
            North American Products
             
            Cause:
            DC control circuit 
             
            Resolution:
            Yes but limited to 24 VDC.

            Contactor LE1D18N7 does it come with overload ?

             No - Overloads can be ordered separatly depending on the current rating required
             

            What replaces LC1D1801U5

             Part code LC1D18U7

            What is the code for a 24vac coil to suit LC1D18B7 Contactor ?

            24V AC Coil =  LXD1B7
            Show More